DC Load Bank for UPS Battery system
DC Load Bank for UPS Battery system
DC Load Bank for UPS Battery system
DC Load Bank for UPS Battery system
DC Load Bank for UPS Battery system
DC Load Bank for UPS Battery system

DC Load Bank for UPS Battery system

Negotiable /Unit

Min.Order:1 Unit

Supply Ability:
50 Unit / Units per Month
Port:
CHINA ANY PORT
Payment Terms:
T/T Credit Card

Quick Details View All >

Place of Origin:
Shanxi, China
Brand Name:
FORESISGHT
Model Number:
FST-CT

Xi'an Foresight Electronics Technology Co., Ltd.

Business Type: Trading Company
Shaanxi China
Main Products: battery capacity analyzer ,laser distance snesor ,battery monitoring system ,battery load tester ,AC Dummy load

Product Details

 

Product Description

 

General:

220V Battery Load Bank is specifically designed for the maintenance of the lead-acid battery discharge in the electricity sector. It is a new high-tech intelligent product that provides safe, reliable and convenient constant testing equipment for the DC system

Product Type:

Different discharge current range

String Voltage

220VDC

 

 

 

Discharge current Range

30A

60A

100A

150A

200A

300A

All above listed items are standard one. The voltage and currency can be customized according to client’s certain demand. When you place order please indicate the voltage, currency, model and function as well as if you need single section supervision by wire or wireless.

Main Functions and Features:

 

DC Load Bank for UPS Battery systemDC Load Bank for UPS Battery system

1,Used to discharge to battery string removed from the system

2,Discharge to Battery string voltage as 220V, Cell voltage as 1.2V/2V/6V/12V

3,4 adjustable stop points and multiple alarm designs to control the discharge process intelligently

4,7inch LCD touch screen for easy operation and showing various parameters real time

5,Support RS232real time monitoring by PC or SD Card download data after discharge

6,PC software for capacity evaluation and report generation

7,Optional wireless modules for 1.2V/2V/6V/12V cells voltage real-time measuring

1,On-line monitoring setting:

 DC Load Bank for UPS Battery system

 

 

Online monitoring for battery string: when the battery string is under the state of online discharge, uniform charge and floating charge, perform real-time online monitoring for all cells. The monitoring includes string voltage, cell voltage, discharge current, monitoring time of battery string, charge/discharge capacity of battery string and etc.

2. Discharge Setting:

 DC Load Bank for UPS Battery system

Perform discharge of constant current taking advantage of intellectualized dummy load after the battery string is removed from system, set up the parameters of “discharge current”,“discharge time ”,“discharge capacity” ,“final protective voltage of whole pack” and“ final protective voltage of cell”, and the tester could carry out discharge function automatically, display discharge current,battery discharged capacity,the whole pack voltage, cell voltage,

Discharge time and etc at real time;

 

Multiple Adjustable Stop Points

Offers 4 adjustable points for test stop points to avoid excessive discharge:

 

 

Stop Point

Setting Range

String Low Voltage

0 - 280.0 V

Discharge Time

0 - 99 Hour 99 Min

Discharge Capacity

0 - 1500 AH

Cell Low Voltage

0 - 15.00 V

 

 

 

 

 

 

1,The instruments can analyze according to main test function on the histogram and the curve chart. It’s unnecessary to upload the result in PC.

 

DC Load Bank for UPS Battery system

 

Technical Specifications: (Take 220V/30A,220V/60A and 20V/100A,220V/150A as sample)

Features

Specifications

Model

  220/30

  220/60

  220/100

  220/150A

String Voltage measurement range

0~285V

String Voltage Resolution

0.01V

Voltage measurement accuracy

0.5%

Cell Voltage Resolution

0.01V

 Discharge current Range

1~30A

1~60A

1~100A

1~150A

Discharge Voltage of Constance current and constant power

180~280V

Resolutions

0.1A

Current measurement resolutions

1%

Power Supply

AC 100V- 220V±15%

50Hz/60Hz

Cooling mode

Air Cooling

Communication Mode

RS232 and SD Card

Display

7inch Touch screen

High-Voltage insulation test

Input-The enclosure:2200Vdc 1min

Input-Output:2200Vdc 1min

Output- The enclosure:700Vdc 1min

Safety standard

EN610950

Work Temperature

-5~50℃

Storage Temperature

-40~70℃

Humidity

Relative humidity 0~90%(40±2℃)

Noise

<60dB

Dimensions

40x225x300mm

480x225x410mm

600x250x410mm

600x225×x630mm

Weight

<10.5Kg

<13Kg

<15.5Kg

<55Kg

      

 

WORKSHOP AND PRODUCTION LINE :

 

DC Load Bank for UPS Battery systemDC Load Bank for UPS Battery systemDC Load Bank for UPS Battery system

 

LABORATORY :

 

DC Load Bank for UPS Battery system

 

PRODUCT TEST :

 

DC Load Bank for UPS Battery system

 

APPLICATION CASE IN CLIENT'S END : 

 

 

DC Load Bank for UPS Battery systemDC Load Bank for UPS Battery system

 

SHIPPING SERVICE : 

 

DC Load Bank for UPS Battery system

 

Contact Supplier

Mr. Jack Lee sales manager Chat Now
Telephone
86-29-87858986
Mobile
13488321607
Fax
86-29-87857695
Address
4/F XI'AN FOREIGN TRADE BUILDING NO. 68 MIDDLE SECTOR SOUTH HUANCHENG ROAD XI'AN CHINA Shaanxi

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Electrical Instruments > Battery Testers
Categories
Hi~