Direct reading spectrometer for high precision
Direct reading spectrometer for high precision
Direct reading spectrometer for high precision
Direct reading spectrometer for high precision
Direct reading spectrometer for high precision
Direct reading spectrometer for high precision

Direct reading spectrometer for high precision

USD $10,000 - $25,000 /Set

Min.Order:1 Set

Supply Ability:
15 Set / Sets per Month
Port:
China any port
Payment Terms:
T/T Credit Card PayPal

Quick Details View All >

Place of Origin:
Jiangsu, China
Brand Name:
JB
Model Number:
JB-750
Size:
L112*W75*H92cm
Weight:
266kg
Focal Length:
750mm

Wuxi Jiebo Electrical Technology Co., Ltd.

Business Type: Manufacturer,Trading Company
Wuxi Jiangsu China
Main Products: spectrometer ,carbon sulfur analyzer ,Spectrometer for metal analysis ,Non-destructive equipments ,Hardness Tester

Product Details

Direct reading spectrometer for high precision

Product Description

 

Description

JB750 Optical Emission Spectrometer is the best assistant for rapid quantitative analysis of metallurgical furnace and metallic quality monitoring. Its accuracy and stability meet laboratory requirements and can make measurements for dozens of matrix based on elements such as Fe,Al,Cu,Ni,Co,Ti,Mg,Zn,Sn,Pb, etc. It is widely used in steel, metallurgy, foundry and machinery for IQC, QC and OQC.
JB-750 is a design of zero fault operation, which requires little maintenance and offering high reliability and convenience.

 

Adjuvant Equipments (self-prepared)
Argon
1. Two cylinders of high purity argon gas. (The purity degree>99.996%)
2. One YQY-6 Oxygen reducing valve.
3. One argon gas purifier.
Power supply 
1. Electronic AC Power Supply(≥3KV, single phase 220V)
2. Independent exclusive Ground line, grounding resistance less than 2Ω, 
Standard samples
Analyzing different materials, choosing curve samples and controlling curves.
Environmental equipment
1. Install air conditioner according to the size of the place laid the apparatus.
2. Install dehumidifier in humid areas.
3. One small vacuum cleaner.

Apparatus installation:
1. The apparatus installation should be guided by the engineers of our company.
2. Check the goods and packing list to affirm that they are qualified and the contents match the instructions.
3. Check whether or not the lab is qualified for using the apparatus.
4. Install and start the apparatus to check if everything works well.
5. Test and adjust according to the requirements on the technical contract. Make sure that the apparatus complies with the requirements.
6. Train the users, including: operate apparatus, use software of the apparatus and daily maintenances of the apparatus.


Equipment acceptance:
Choose one or two sets of national standard samples appointed by both parties and check the equipment ,Check Spectrometer metal testing  and analyze the precision with repeated acceptance checking program and fill the installation and acceptance checking report.


After-sales service:
1. This apparatus has a 12-month warranty since the date of install and inspection.
2. Beyond the warranty period, company will still provide after-sales service.

 

Control System:
Measurement and Control System: The single board computer measurement and control, data exchange with the Host Computer
Reproducibility: RSD ≤ 0.2%
Photomultiplier tube high voltage power supply:
Stability: 8 hours is better than 0.5%

Data processing system
1, Hardware configuration (basic configuration)
Computer
Printer
2, Software functions
Multi-languages operation software under WINDOWS operation system
Various samples calibrate one analysis result simultaneously
Polygon and polynomial curve fitting
The concentration base of drawing curve management
Matrix correction and disturbance correction
There is a power management module
Quality controlling standard and management
System condition inspection
Data outputting management

 

 

Main Parameters
Excitation light source:
Supply voltage: 50Hz, 220V ± 1%
Input power: 1.0KVA
Charging capacitor: pre-combustion 8μF, exposure 1.5μF
Peak Current: pre-combustion 100A, exposure 20A
The main circuit peak pressure: 300VDC (with automatic adjustment of peak pressure)
Ignition circuit: pulse amplitude: +15 KV
Auxiliary gap: Using Tunnel Diode
Discharge frequency: 200 Hz ~ 600 Hz
Sample sets of gap: 4mm
Spectrometer:
Analysis band range: 160 ~ 650nm
Machine engraved concave grating: Curvature radius of 750mm
Depicts the density: 1667/mm
Incidence angle: 35 degrees
Allows a maximum of channels: 40 (expandable to 64 channels)
Spectrometer Local temperature: 35 °C ± 0.5 °C
Control System:
Measurement and Control System: The single board computer measurement and control, data exchange with the Host Computer
Reproducibility: RSD ≤ 0.2%
Photomultiplier tube high voltage power supply:
Stability: 8 hours is better than 0.5%

 

Test result


Direct reading spectrometer for high precision
 
Technical parameters

  Direct reading spectrometer for high precision

Optical System:

Excitation Desk:

  • Palmer type - runge device
  • Focal length of grating: 750mm
  • Wavelength range: 130-650nm
  • Open spark desk
  • All kinds of fixture for special applications
  • A cyclic flow saves the argon gas design
  • Can quick swab incident window and replace
  • Gap analysis: 4 mm

Excitation Light Source:

  • Programmable pulse digital light source
  • Discharge frequency: 100 -1000Hz
  • High-energy pre-combustion technology
  • Ignition pulse amplitude: +15KV
  • Peak pressure of main loop: 400VDC

Working Environment and Power Supply:

  • Power supply: 220V±10%,50Hz±2%
  • Max power: 1000W, standby 200W
  • Working temperature: 10-30℃
  • Relative humidity: 20-80%RH

Requirement of Argon Gas:

  • Purity>99.996%
  • Inlet pressure: 0.5MPa
  • Excitation flow: 3L/min

Size and Weight:

  • Size: L112×W75×H92cm
  • Weight: 266 kg / 586 lb

 

Packaging & Shipping

Direct reading spectrometer for high precision

Direct reading spectrometer for high precision

 

Our Services

Direct reading spectrometer for high precision

Direct reading spectrometer for high precision 

Certifications

Direct reading spectrometer for high precision 

Company Information

Direct reading spectrometer for high precisionDirect reading spectrometer for high precision 

The exhibition

Direct reading spectrometer for high precision Direct reading spectrometer for high precision

 

Contact Supplier

Ms. Susan Yang mananger Chat Now
Telephone
86-510-83211967
Mobile
18118915721
Fax
86-510-84060385
Address
35#,Jingsheng Road,Qianqiao Development Area Wuxi,Jiangsu

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Optical Instruments > Spectrometers
Categories
Hi~