Rainproof 360W LED AC/DC 220v ac 24v dc switching power supply
Negotiable /Piece
Min.Order:100 Pieces
Shenzhen G&G Technology Co., Ltd.
220v ac 24v dc switching power supply.
Input voltage:170-250VAC
Output voltage:5V, 12V ,24V
Output current: 70A, 30A, 15A
Output power:360W
Features 1,Non-waterprooof design for indoor use only
2,Protections: Short circuit / Overload/Over temperature
3,Products through CE, RoHS Certification
Specification:
Model | S-360-5 | S-360-12 | S-360-24 |
DC output voltage | 5V | 12V | 24V |
Output voltage error(Note2) | ±2% | ±1% | ±1% |
Rated output current | 70A | 30 | 15 |
Output current rage | 0-70A | 0-30A | 0-15A |
Wave and noise(Note 3) | 100mVp-p | 125mVp-p | 150mVp-p |
Inlet stability(Note 4) | ±0.5% | ±0.5% | ±0.5% |
Load stablity (Note 5) | ±1% | ±0.5% | ±0.5% |
DC output power | 360W | 365W | 370W |
Efficiency | 76% | 80% | 83% |
Adjustable range for DC voltage | 10% | 10% | 10% |
AC input voltage range | 85-132VAC /176~264VAC selected by swich 47~63Hz;248~370VDC | ||
Input current | 2A/115V 1A/230A | ||
AC INnrush current | Cold-start current30A/115V 60A/230V | ||
Leakage current | <1mA/240VAC | ||
Overload proctection | 105%-150%Type:Foldback:current limiting reset:auto recovery | ||
Over-voltage protection | 115%-135 | ||
High-temperature protection | Yes | ||
Temperature coefficient | ±0.03%/°C(0-50°C) | ||
Setup rise hold up time | 1s,30ms,15ms | ||
Vibration | 10-500Hz,2G 10min,/1cycle,Period for60min,Each axes | ||
Withstand voltage | Input and output internal: 1.5KVAC,Input and enclosure : 1.5KVAC,Output and enclosure: 0.5KVAC | ||
Isolation resistance | Input and output internal:Input and enclosure,Output and enclosure: 500VDC/100MΩ | ||
Working temperature and humidity | -10°C~+60°C(Refer to output derating curve),20%~90%RH | ||
Store temperature and humidity | -20°C~+85°C.10%~95%RH | ||
Overall dimension | 199×98×38mm | ||
Weight | 0.65Kgs | ||
Safety standards | UL1012 TUV EN6050(IEC950,UL1950)Approved | ||
EMC standards | CISPR22(EN55022),IEC801-2,3,4,IEC555-2 Verification | ||
Note | |||
1.The testing condition for the paramenter above is :230VAC input,rated load,25°C70% RH.Humidity. | |||
2.Error.include the setting error,line stability and load stability.(Note:5). | |||
3.Wave test:adopting "A12"double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting. | |||
4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage. | |||
5.Load stability test:the load is from 0% to 100%. |