UQK-71 float ball liquid level gauge
USD $1 - $500 /Set
Min.Order:1 Set
Shenyang Beixing Meter Manufacture Co., Ltd.
UQK-71 float ball liquid level gauge
General information
UQK-71 float liquid level controller is made of sensor and display controller.
It is widely used in the industries of petroleum, chemical, medicine, sewage treatment and so on for measuring the liquid in the open or the closed containers.
The structure of the sensor and the measuring principle
The liquid sensor is made of magnetic floating ball, measuring pipeline, flange(or thread or supporting board) and junction box.
There are many reed pipes and other elements in the measuring pipeline, when magnetic ball change the position up and down with the liquid level, the single will be transfer to the display controller by magnetic coupling.
Types of the sensor
According to the single nature of the sensor, can be divide three types
1. high power and single of the reed tubes output directly, like UQK-71G
2. low power and singe of the reed tubes output, like UQK-71K
3. analogue value output, like UQK-71M
The main technology parameters
1. Measuring range: ≤6000mm(according to the clients’ demand)
2. Measuring error: ≤ ±5mm
3. The capacity of the reed tubes
High power:220V.AC.2A
Lower power: 220V.AC.0.1A;24V.DC.0.3A
4. Working pressure: ≤2.5MPa
5. Medium parameters
Temperature:-20~120°C
Density:≥0.65g/cm3
Viscosity:≤1.25st
6. Environment condition
Temperature:-40~50°C
Relative humidity:≤85%
7. Connection way: flange, thread, or supporting board
(1)Flange standard: DN125;150, PN0.6;1.0;1.6;2.5MPa, HG20592~20635-97(or other standard)
(2)Thread standard: M72*4(suitable density≥1.0g/cm3, floating ball out diameterΦ65)
(3) Supporting board:150*60mm
8. Material:
Flange: carbon steel, 1Cr18Ni9Ti,PVC plastic, Four fluorine spraying
Floating ball: 1Cr18Ni9Ti,316,Ti,PVC plastic, Four fluorine spraying
Pipeline: 1Cr18Ni9Ti,316,PVC plastic, Four fluorine spraying
9. The sensor with explosion protection
Mark: dIIBT1-4
Protection class:IP65
The relationship between the explosion temperature and medium temperature:
temperature | T1 | T2 | T3 | T4 |
Medium temperature | 400 | 290 | 190 | 130 |
10 Structure and Name