Thermal Camera PCE-TC 31
Negotiable /Set
Min.Order:1 Set
TC 31 also enables accurate positioning in the investigation or when shooting during maintenance. The stored thermal imaging can be transferred via the respective connecting cable to a PC or laptop. The internal 64 MB memory can store about 1,000 radiometric images for later analysis on a PC. An analysis software is also in the delivery.
-160 x 120 Pixel - 60Hz Frame frequency - Hot Spot and Cold Spot - automatic temperature range adjusting | - ≤ 0.1 °C thermal sensitivity - 1.3 mrad spatial resolution - 2.5 ” color LCD - PC-Reporter Software included | |
Technical specifications of the themal-camera PCE-TC 31 | ||
Detector Performance | ||
Type | Uncooled focal plane | |
Resolution | 160 x 120 Pixel | |
Range of λ | 8 ...14 μm | |
Thermal sensitivity | ≤0.1 °C @30 °C | |
Image Performance |
| |
Frame frequency | 60 Hz | |
LCD | High resolution 2.5 ” color LCD | |
Lens parameter |
| |
Field of view | 18° × 13 ° | |
Focusing | 0,3 m ... ∞ | |
Focus type | Manual | |
Spatial resolution | 1.9 mrad | |
Measurement analysis |
| |
Measurement range | -20 ... +350 °C | |
Measurement accuracy | ±2°C | |
Palette | 3 | |
Measurement calibration | Auto/Manual | |
Measurement mode | Spot temperature measurement and area temperature measurement (Maximum, minimum and mean value) | |
Quantity of measurement spot | 1 | |
Quantity of measurement area | 1 | |
Measurement analysis mode | Isothermal temperature, Temperature difference, Temperature alarm (voice, color) | |
Setting function | Date/Time, Temperature unit °C / °F / K, Language | |
Emissivity revise | Range: 0.01 ... 1.0 or revise according the pre-defined emissivity table. | |
Background temperature revise | Auto, based on the background temperature | |
Image storage |
| |
Medium type | Internal Flash | |
Capacity | 64 MB | |
Store Type | Manual single frame image save | |
File format | JPEG, 14 bits data | |
File size | 60 KB (typical value) | |
Laser |
| |
Laser indicator | Second class,2,1 mW/ 635 nm Red | |
Power system |
| |
Battery type | Rechargeable lithium battery | |
Battery working time | ≥3 h | |
Power save mode | Yes | |
Environment parameter |
| |
Ambient temperature | -15 ... +50 °C | |
Humidity | ≤90 % r.H. (Non-condensable) | |
Preventive class | IP54 | |
Appearance |
| |
Size | 250 mm x 100 mm x72 mm | |
Weight (exclude battery) | 0,6 kg | |
nterface |
| |
USB | Standard Mini USB interface |
1x Thermal camera PCE-TC 31
1x Reporter software
1x USB cable
1x Lithium batteries
1x Battery charger
1x Lens cap
1x Adumbral cover
1x Manual PCE-TC 31
1x Manual Reporter Software