Aerial Bounded Cable ABC Copper/ Aluminium Conductor PVC/PE/XLPE/HDPE Insulated Cable Quality Choice
USD $8.00 - $8.00 /Meter
Min.Order:100 Meters
Chongqing Yufeng Wire & Cable Co., Ltd.
Type:Low/Medium Voltage
Color: Black
Certification:CE,CCC,ISO9001,ISO14001,ASG CNAS
Aerial Bounded Cable ABC Copper/ Aluminium Conductor PVC/PE/XLPE/HDPE Insulated Cable
Aerial Bouned Cables with rated voltage up to and including 1kv
Standard
The product is manufactured according to the standards of GB12527-2008 <<Aerial insulated cables of rated voltage up to and including 1kv>>
<<Extruded solid dielectric power cables for rated voltage from 1kv to 30kv>>.
Operating characteristics
Rated voltage U./U:1kv
Max.permissible continuous temperature:
PVC,PE insulated aerial cables:70C;
XLPE insulated aerial cables: 90C
Max.short-circuit temperature of the conductor shall not exceed:
PVC insulated aerial cables:160C;
PE insulated aerial cables: 130C;
XLPE insulated aerial cables:250C.
The installation ambient temperature should not below -20C.
The bending radius of cables are recommend as follows:
When the diameter of cables less than 25mm: not less than 4 times the diameter of cables;
When the diameter of cables not less than 25mm; not less than 6 times the diameter of cables.
When the cables use in alternating current system, rated voltage of cables should be at least equal the rated voltage of the system; When the cables use in direct current system, rated voltage of the system should be not greater than 1.5 times of the rated voltage of the cables.
Aerial Bouned Cables with rated voltage 10kv and 35kv
Standard
The product is manufactured according to the standards of GB/t14049-2008
Operating characteristics
Rated voltage : 10KV,35KV
Max.permissible continuous temperature:
HDPE insulated aerial cables:75C;
XLPE insulated aerial cables: 90C
Max.short-circuit temperature of the conductor shall not exceed:
HDPE insulated aerial cables:150C;
XLPE insulated aerial cables:250C.
The installation ambient temperature should not below -20C.
The bending radius of cables are recommend as follows:
Single cable: not less than 20 times the diameter of cables;
Multi-core cables: not less than 15 times the diameter if cables.
Type | Designation | Main Application | |||||||
JKV-0.6/1 | Cu core PVC aerial insulated cable with rated voltage 0.6/1kV | Aerial fixed laying and leading wire | |||||||
JKLV-0.6/1 | Al core PVC aerial insulated cable with rated voltage 0.6/1kV | ||||||||
JKY-0.6/1 | Cu core PE aerial insulated cable with rated voltage 0.6/1kV | ||||||||
JKLY-0.6/1 | Al core PE aerial insulated cable with rated voltage 0.6/1kV | ||||||||
JKYJ-0.6/1 | Cu core XLPE aerial insulated cable with rated voltage 0.6/1kV | ||||||||
JKLYJ-0.6/1 | Al core XLPE aerial insulated cable with rated voltage 0.6/1kV | ||||||||
JKLGYJ-0.6/1 | Al conductor (steel-reinforced) XLPE aerial insulated cable with rated voltage 0.6/1kV | ||||||||
|