8KVA single in/single out power frequency UPS(single phase UPS)
USD $50 - $2,000 /Piece
Min.Order:1 Piece
Shenzhen Goter Power Technology Co., Ltd.
Single in/out power frequency UPS
1. Product presentation:
HR8108 series single in/out UPS is the excellent performance sine wave online UPS which aims at high reliability power supply requirement of Chinese grid environment and network system, designed for financial, telecommunications, insurance, transportation, taxation, military, securities, energy, education, government, enterprises the network computer rooms and small smart devices, precision instruments etc. particularly for the poor grid environment.
HR8108series single in/out power frequency on-line UPS with Chinese grid environment design concept which should be the best partner for ensuring network system to run steadily. There is also optional harmonic suppression filters, isolation transformers, and SNMP adapter etc for users.
2. Technical characteristics:
With Chinese grid environment design concept, improve system usability.
High reliable design concept, ensure network system to run steadily.
Intelligent battery management technology, to effectively extend the battery life.
Perfect protection function and guarantee the system stability and reliability
Human-based machine operation interface and network management function which make operation more easily.
3. Technical data:
Input voltage | Single phase 160~275VAC |
Output frequency | 50(60) Hz ±5% |
Output voltage | Single phase 220VAC |
Output frequency | 50(60) Hz |
Voltage stability | ±1% |
Frequency stability | ±0.5% (mains power failure) |
Power factor | 0.8 (lag) |
Waveform | SPWM sine wave |
Distortion | <3% (linear load) |
Transient response | Voltage change ≤4%(100% load on or take off) |
Output current crest value | 3:1 (Max.) |
Overload | Overload ((120—150%)automatically turn to bypass after 60s, resume after load is normal. |
Over temperature | When UPS inner temperature >85°C, automatically turn to bypass. |
Short circuit | Limit current, automatically turn off, miniature circuit breaker protection |
LCD screen | Display UPS running status, input/ output voltage, input/output frequency, output power(%)l inverter temperature |
Environment temp. | 0~40°C |
Environment humidity | no condensation |
Frequency | >85% |
Communication interface | RS232 interface, can external build SNMP card; optional RS485,DB9 stem nodes |
Max. elevation | Less than 1000m |
Noise | <58dB (1m to cabinet) |
4. Models
Models | Capacity | Dimension L*W*H (mm) | Weight | Max. output current (A) |
HR8101 | 1KVA | 250×580×700(standard ) 250×580×540(Long time)
| 60 | 6 |
HR8102 | 2KVA | 70 | 12 | |
HR8103 | 3KVA | 80 | 18 | |
HR8104 | 4KVA | 250×580×700 | 68 | 24 |
HR8106 | 6KVA | 75 | 34 | |
HR8108 | 8KVA | 310×590×850 | 110 | 45 |
HR8110 | 10KVA | 115 | 56 | |
HR8115 | 15KVA | 410×680×1020 | 200 | 82 |
HR8120 | 20KVA | 230 | 112 |
5. The pictures of single in/out power frequency UPS
6. Pictures of factory:
7.certification