Three phase in 1 output online UPS
USD $300 - $5,000 /Piece
Min.Order:1 Piece
Shenzhen Goter Power Technology Co., Ltd.
Technical Data
Size | GTHR8300 |
capacity | 10K-40KVA |
AC input | |
voltage | Three phase input 380VAC±20% |
Frequency | 50(60) Hz ±5% |
Maximum current | 56A |
AC output | |
voltage | Single phase 220VAC |
Frequency | 50(60) Hz |
Voltage stability | ±1% |
Frequency Stability | ±0.5% (Mains power failure) |
Waveform | SPWM Sine wave |
Power factor | 0.8(Hysteresis) |
Distortion | <3%(Linear load) |
Transient response | Voltage variation ≤ 4% (100% load into or cut out) |
Output current crest factor | 3:1 (Max.) |
Battery | |
Voltage | 192VDC |
Type | Maintenance-free lead-acid batteries |
Charging time | Completed 90% capacity within 8-10 hours |
Warning devices | |
Mains power | The buzzer beeps once every 4 seconds |
Mains abnormal | The buzzer beeps once every four seconds, mains mode indicator flashes |
The battery will run out | The buzzer beeps once every second, the battery mode indicator flashes, battery low voltage lights |
Overload | Overload indicator light, buzzer sounding |
UPS Abnormal | Malfunction indicator light, buzzer sounding |
Internal protection | |
Battery | Low battery automatic shutdown, automatic restart utility power is restored, miniature circuit breaker protection |
Overload | Go to bypass automatic overload (120-150%) after 60 seconds, after the resumption of normal load |
Over Temperature | UPS internal temperature> 85 °C automatically go to bypass |
Output short circuit | Limiting, automatic shutdown, mini circuit breaker protection |
UPS Abnormal | Automatically go to bypass the mains load |
Clutter filter | 10~100KHz at 40dB; 100KHz~100MHz at 70dB |
Control Panel | |
LCD Display | UPS operating status display, input, output voltage; input and output frequency; battery voltage; Output Power (%); inverter temperature |
Low battery indicator | When the battery voltage is low light |
Overload indicator | Overload light |
Fault indicator | Failure light |
UPSStatus Indicator | AC mode; battery mode; inverter power supply; bypass supply; UPS abnormal |
Safety standand | |
Safety | GB4943 |
EMI | IEC62040-2,GB7260.2 |
EMS | IEC61000-4-2~5,GB/T 17626.2~5 |
Environment | |
Temperature | 0~40°C |
Humidity | 20~90% Non-condensing |
Elevation | Less than 1000m (above sea level for each additional 500m, UPS output derating 5%) |
Noise | <58dB (at 1 m from the box) |
Appearance | |
Input and output wiring | Terminal Blocks |
Weight (without battery)Kg | 350 |
Size W×D×H (mm) | 725×430×1180 |
Others | |
conversion time | >87% |
Mains power conversion time | 0ms |
Inverter / bypass transfer time | ≤1ms |
Communication Interface | S232 interface for direct external SNMP card; RS485, DB9 dry Node Optional |