Online Circulation mobile type transformer oil treatment plant
USD $16,800 - $22,500 /Set
Min.Order:1 Set
Chongqing Assen Power Equipment Co., Ltd.
Save operation costs type Insulation oil purifier machine,Insulation oil purification
ZYD type transformer oil purifier machine with good performance
On-Site Transformer Oil Purification system,ZYD Oil Purifier,Oil Reconditioning Plant
oil filled transformer oil purifier,HV transformer oil filtering plant
ZYD high efficiency Transformer Oil Dewatering and Filtration unit
Online Circulation mobile type transformer oil treatment plant
According to fieldwork requirement, ZYD-M Mobile transformer oil treatment equips the car wheels, which can be easy to move to any work point by traction. It is special suitable for purifying the transformer oil which locate in different fields. This machine can recover the seriously transformer oil. The treated transformer oil can reuse again in transformer.
ZYD-M mobile transformer oil treatment plant is used for transformer oil dehydration and transformer oil degasification and vacuum filling oil to transformer, remove impurities from oil as well as other electrical insulating liquids such as silicone fluids. The ZYD-M Process is able to increase and maintain the oil's dielectric strength and includes the removal of free and soluble water, free and dissolved air and gases and particulate matter. The standard ZYD-M system is designed for processing oils in workshops, in storage tanks or directly in transformers (energized or de-energized transformers).
1.To remove free, soluble water, carbon, free and dissolved gases and particulate matters from insulating oil effectively and rapidly.
2.Enhance the value of breakdown voltage greatly.
3.Easy handling and maintenance.
4.Inject oil into the transformers
5.Online work
6.Lower maintenance and replacement expenses
7.High efficiency and effectiveness
8.Available in mobile or stationary options.
9.Small size, light weight, low noise
10.Various sizes and configurations (alloy shield) available.
Even after years of apparent trouble-free operation, transformer oil can start to degrade. Overheating of the oil and other conditions accelerate this problem causing formation of sludge. Any sludge that develops deposits itself on the windings, which causes the transformer to operate less efficiently and speeds up the degradation of the oil.
ASSEN ZYD-M Mobile Transformer Oil Treatment plant cleans oil, transformer windings, and paper insulation, allowing for years of safe and continued use of electrical equipment.
Mobile transformer oil treatment's Technical Data:
Parameters | Unit | ZYD-30 | ZYD-50 | ZYD-100 | ZYD-150 | ZYD-200 | ZYD-250 | ZYD-300 | |
Flow | L/min | 30 | 50 | 100 | 150 | 200 | 250 | 300 | |
Working vacuum | MPa | 0.08 ~ 0.099 | |||||||
Working Pressure | MPa | ≤0.3 | |||||||
Breakdown Voltage | KV | ≥75 | |||||||
Water Content | PPM | ≤3 | |||||||
Gas Content | % | ≤0.01 | |||||||
Impurity Size | μ | ≤5 | |||||||
Temperature Range | °C | 20 ~ 80 | |||||||
Power |
| Three Phase 50HZ380V(as per the customer's requirements) | |||||||
Working Noise | dB(A) | 75 | 75 | 75 | 80 | 80 | 80 | 80 | |
Heating Power | kW | 30 | 30 | 45 | 60 | 75 | 90 | 120 | |
Total Power | kW | 35.5 | 37.5 | 52.5 | 71.4 | 86.5 | 102.5 | 135 | |
Inlet/Outlet | mm | φ25 | φ32 | φ42 | φ50 | φ50 | φ60 | φ60 | |
Weight | kg | 600 | 800 | 1050 | 1400 | 1800 | 2000 | 2200 | |
Overall | Length | mm | 1050 | 1100 | 1200 | 1450 | 1600 | 1800 | 1900 |
Width | mm | 750 | 800 | 950 | 950 | 1100 | 1200 | 1200 | |
Height | mm | 1350 | 1400 | 1500 | 1650 | 1800 | 1900 | 1900 |
Structure Chart:
The oil technical data after treatment:
Item | Guarantee indexes |
Moisture content | ≤3PPM |
Impurity size | ≤1 micron |
Gas content | ≤0.1% |
Breakdown voltage | ≥75 |
Mobile transformer oil treatment's Advantage:
Comparing with the single-stage type, this machine adopts the double stages vacuum system, which can improve the machines working vacuum value highly, so it can dewater, degas and remove the impurity more deeply and effectively. The dielectric value of treated oil is higher than 75 KV. It is very suitable for the large electric & insulation equipments
Q: How can we achieve drying without elevated heating of the insulation material for transformers?
A: Drying of insulation materials can be achieved at low temperature and low pressure levels. The pressure levels and temperature levels for drying vary for distinct material. At low pressure or under vacuum the rate of water vapour evaporation is accelerated if sufficient heat is provided to the insulation material. Thus we can achieve a good drying of insulating material if the material is suitably heated and subjected to vacuum.
Chongqing Assen Power Equipment Co.,LTD, which is professional in design, manufacture, sale of oil purification equipment, relevant testing instruments and provide comprehensive filtering solution, owns advanced production lines and sophisticated detection equipment, first-class R & D staff , professional workers and High-quality sales and service teams
Our Product: Double Stage Transformer Oil Purification system, Vacuum Lubricating Oil Purification, Vacuum Turbine Oil Conditioner, Portable Oil Purifier, Singe Stage Insulating Oil Purifier, Water Oil Separator, Light fuel Oil Purifier, and Fully-auto Dielectric Oil Tester, Turn ratio Tester, Acid Tester, Moisture Detector, Interfacial Tension Tester, etc.
Our Service: special filter technology consulting and solutions sector; fast after-sale service feedback system, well-trained service engineer; hands-on training and large-scale equipments operation myrmidon; regularly visit system, CRM customer relationship management system; rapid Filter wearing parts and spare parts supply system.
We welcome new and old customers from all walks of life to contact us for future business relationships and mutual success!