ZYD high efficiency Transformer Oil Dewatering and Filtration unit
USD $13,600 - $25,500 /Set
Min.Order:1 Set
Chongqing Assen Power Equipment Co., Ltd.
ZYD high efficiency Transformer Oil Dewatering and Filtration unit
Specifications
Remove water content from the oil, can deal with the tiny water which cannot be seen by the eyes, the index reach 1-5 PPM.
This Transformer Oil dewatering Plant used in:
1, Remove water content from the oil, can deal with the tiny water which cannot be seen by the eyes, the index reach 1-5 PPM.
2, Remove the waste gas from the oil, which made the oil bad smelling and damage the oil specification.
3, The impurities after treat just 5um.
4, With the BZ oil regeneration system, can refine the oil color to colorless, like the water.
5, The breakdown voltage after treated, can be 65-75KV.
6, It is largely used in the area of electric factory, station and company, transformer industry, railway, petrochemical industry, metallurgy etc.
1. The Transformer Oil Dewatering Plant with the high efficiency.
2, The vacuum oil purification is portable and small size, so you can use it everywhere.
3, It is very suit to operate on line. Also it can be used to dry the electric equipment and input the oil into the electric equipment under the vacuum state.
4,The vacuum oil purification is automatic control.
5, With the alarm, when the temperature and pressure exceed the index, all the parts will stopped.
6. High vacuum limiting vacuum less than 5pa, working vacuum less than 35pa.
7. Environment friendly.
8, Power cost less.
9, Strong and stable.
10, With the engineer installation.
11, We can take the special order as the customer need.
ZYD series Transformer oil dewatering unit is mainly used to extend the lifetime of oils used in transformers, circuit breakers, mutual inductor, voltage regulators and switch gear, or to inject the insulating oil into the transformers. Equipped with regenerators, ASSEN transformer oil dewatering machine can improve the effect of de-acid, de-color and remove dielectric and acid more effectively. The value of breakdown voltage will increase from 15KV to 75KV. The performance and lifetime of insulating oil will improve and extend awfully after purification and regeneration.
Transformer oil dewatering unit's Technical Data:
Parameters | Unit | ZYD-30 | ZYD-50 | ZYD-100 | ZYD-150 | ZYD-200 | ZYD-250 | ZYD-300 | |
Flow | L/min | 30 | 50 | 100 | 150 | 200 | 250 | 300 | |
Working vacuum | MPa | 0.08 ~ 0.099 | |||||||
Working Pressure | MPa | ≤0.3 | |||||||
Breakdown Voltage | KV | ≥75 | |||||||
Water Content | PPM | ≤3 | |||||||
Gas Content | % | ≤0.01 | |||||||
Impurity Size | μ | ≤5 | |||||||
Temperature Range | °C | 20 ~ 80 | |||||||
Power |
| Three Phase 50HZ380V(as per the customer's requirements) | |||||||
Working Noise | dB(A) | 75 | 75 | 75 | 80 | 80 | 80 | 80 | |
Heating Power | kW | 30 | 30 | 45 | 60 | 75 | 90 | 120 | |
Total Power | kW | 35.5 | 37.5 | 52.5 | 71.4 | 86.5 | 102.5 | 135 | |
Inlet/Outlet | mm | φ25 | φ32 | φ42 | φ50 | φ50 | φ60 | φ60 | |
Weight | kg | 600 | 800 | 1050 | 1400 | 1800 | 2000 | 2200 | |
Overall | Length | mm | 1050 | 1100 | 1200 | 1450 | 1600 | 1800 | 1900 |
Width | mm | 750 | 800 | 950 | 950 | 1100 | 1200 | 1200 | |
Height | mm | 1350 | 1400 | 1500 | 1650 | 1800 | 1900 | 1900 |
Structure Chart:
The oil technical data after treatment:
Item | Guarantee indexes |
Moisture content | ≤3PPM |
Impurity size | ≤1 micron |
Gas content | ≤0.1% |
Breakdown voltage | ≥75 |
Transformer oil dewatering unit's Advantage:
1 Enhance the value of breakdown voltage of oil greatly.
2 Easy handling and maintenance. It is available that online work. The plant can provide the ability of injection oil into the transformers without extra accessory.
3 Lower maintenance and replacement expenses.
4 High efficiency and effectiveness while small size, light weight, and low noise.
Q: How can we achieve drying without elevated heating of the insulation material for transformers?
A: Drying of insulation materials can be achieved at low temperature and low pressure levels. The pressure levels and temperature levels for drying vary for distinct material. At low pressure or under vacuum the rate of water vapour evaporation is accelerated if sufficient heat is provided to the insulation material. Thus we can achieve a good drying of insulating material if the material is suitably heated and subjected to vacuum.
Chongqing Assen Power Equipment Co.,LTD, which is professional in design, manufacture, sale of oil purification equipment, relevant testing instruments and provide comprehensive filtering solution, owns advanced production lines and sophisticated detection equipment, first-class R & D staff , professional workers and High-quality sales and service teams
Our Product: Double Stage Transformer Oil Purification system, Vacuum Lubricating Oil Purification, Vacuum Turbine Oil Conditioner, Portable Oil Purifier, Singe Stage Insulating Oil Purifier, Water Oil Separator, Light fuel Oil Purifier, and Fully-auto Dielectric Oil Tester, Turn ratio Tester, Acid Tester, Moisture Detector, Interfacial Tension Tester, etc.
Our Service: special filter technology consulting and solutions sector; fast after-sale service feedback system, well-trained service engineer; hands-on training and large-scale equipments operation myrmidon; regularly visit system, CRM customer relationship management system; rapid Filter wearing parts and spare parts supply system.
We welcome new and old customers from all walks of life to contact us for future business relationships and mutual success!