ETCR4200A Intelligent Double Clamp Digital Phase Volt-Ampere Meter

ETCR4200A Intelligent Double Clamp Digital Phase Volt-Ampere Meter

USD $878.91 - $878.91 /Set

Min.Order:1 Set

Supply Ability:
0 per Month
Port:
QINGDAO
Payment Terms:
T/T Credit Card PayPal

Quick Details View All >

Place of Origin:
China
Brand Name:
ETCR
Model Number:
ETCR4200A

Qingdao Zhibohongyu Trading Co., Ltd.

Business Type: Trading Company
Qingdao Shandong China
Main Products: Thermometer ,Multimeter ,Distance Meter ,Gas Detector ,Sound Level Meter

Product Details

 

Product Description

 ETCR4200A Intelligent Double Clamp Digital Phase Volt-Ampere Meter

.Introduction
  
    ETCR4200A Intelligent Double Clamp Digital Phase Volt-Ampere Meter is a well-developed full-automatic, multi-functional, digital, intelligent meter specifically designed for field testing, which is a overall upgrade product based on mechanical knob phase volt-ampere meter, can simplify operation and reduce the possibility of misoperation, featuring high accuracy, high stability, low power consumption, easiness to use and so on. It can directly measure AC voltage and AC current without opening the measured circuit, phases between three voltages, three currents and phase between the voltage and current; in addition, the power factor and power of the circuit can be indirectly measured, it can also be used to distinguish three-phase sequence, transformer wiring group, inductive and capacitive circuits, test second circuit and bus differential protection systems, read the phase relationship between CTs of the differential protection, check the meter wiring right, repair lines and equipment, etc. Apply to electric power, petroleum chemical industry, metallurgy, railway, and meteorology, industrial and mining enterprises, scientific research institutions, measurement sector and so on. Especially for the electricity billing system and relay protection system, and electricity measurement, electricity check,  power inspection for power marketing department. Assembling, relay protection, differential detection, start experiment, substation overhaul, or power practical training, skills match for biotech department.

   

    ETCR4200A Intelligent Double Clamp Digital Phase Volt-Ampere Meter has well designed shell mould made of newest material, attach with shakeproof, skidproof, high insulation sheath, has a 240dots×160dots LCD screen, all the test data display on the screen simultaneously, vector diagram indication, and looks exquisite and comfortable. Meter equipped with USB-RS232 interface, can store 500 sets of data, through the system software upload stored data to the computer, implementing online real-time monitoring and historical inquires, dynamic display. Can read, save, report, print history data, etc. Its big round clamps are applicable to thick wire detection.
      
   

   

Technical Specifications 
   1Base Conditions and Working Conditions
   
Influence Quantity
Base Condition
Working Condition
Remark
Ambient Temperature
23C±1C
-10C~40C
----
Ambient Humidity
40%~60%
<80%
----
Signal Waveform
sine wave
sine wave
β=0.01
Signal Frequency
50HZ±1HZ
45HZ~65HZ
----
Meter Working Volt
9V±0.1V
9V±1.5V
----
Current Amplitude in Phase/Frequency/Phase Sequence Test
1A±0.2A
2mA~20A
----
Voltage Amplitude in Phase / Frequency/ Phase SequenceTest
100V±20V
10V~600V
----
Current Amplitude in Power / Power Factor Test
1A±0.2A
20mA~20A
----
Voltage Amplitude in Power / Power Factor Test
100V±20V
10V~600V
----
External Electric Magnetic Field
To be avoided
Measured Wire Position
Measured wire at approximately the geometric center of the clamp

   

2 Intrinsic Error and Performance Indicators under Base Conditions

CategoryMeasurement RangeResolutionIntrinsic Error
VoltageAC 0.0V~600V0.01V±(1.5%rdg+3dgt)
CurrentAC 0.0mA~20.0A0.1mA±(1.5%rdg+3dgt)
Phase0.0°~360°0.1°±1°
Active Power0.0W~12kW0.1W±(3%rdg+3dgt)
Reactive Power0.0VAR~12kVAR0.1VAR±(3%rdg+3dgt)
Apparent Power0.0VA~12kVA0.1VA±(3%rdg+3dgt)
Frequency45HZ~65HZ0.01HZ±(2%rdg+3dgt)
Power Factor-1~+10.001±0.03

   

3 General Specification

FunctionSimultaneous measurement of two AC voltage, current, phase between voltage, phase between current, phase between voltage and current, frequency, phase sequence, active power, reactive power, apparent power, power factor, distinguish transformer wiring group, inductive and capacitive circuits, test second circuit and bus differential protection systems, read the phase relationship between CTs of the differential protection, check the meter wiring right, repair lines and equipment, etc.
PowerDC9V alkaline batteries(1.5V AA×)
ConsumptionAbout 70mA at most with enabled backlight, battery working continuously for about 14 hours
About 40mA with disabled backlight, battery working continuously for about 20 hours
Display ModeLCD display, 240dots×160dots
Meter SizeLength, Width, Height:196mm×92mm×54mm
Clamp Sizeround current clamp:35mm×40mm
Measurement Range
           
(automatic shift)
AC Voltage:0.00 V~600V (automatic shift)
AC Current:0.0mA~20.0A (automatic shift)
Phase:0~360°
Frequency:45.00Hz~65.00Hz
Active Power:0.0W~12kW
Reactive Power:0.0W~12kVAR
Apparent Power:0.0W~12kVA
Power Factor:-1~+1
ResolutionVoltage:AC 0.01V
Current:AC 0.1mA
Phase:0.1°
Frequency:0.01Hz
Active Powe:0.1W
Reactive Power:0.1VAR
Apparent Power:0.1VA
Power Factor:0.001
Sample RateAbout 2 times/second
Data HoldPress HOLD key to keep data, "DH" symbol appears
Data Storage1500 sets
RS232 InterfaceUSB-RS232 interface, download data to computer for analysis and management
Automatic ShutdownAutomatic shutdown about 15 minutes later after launching to reduce battery consumption
BacklightingSuitable for dark place and nightly use
Voltage DetectionLow battery symbol “     " appears to remind the replacement of battery when the battery voltage drops below 7.2V.
WeightMain Unit about 550g(with battery),acuminate current clamp about 170g×3, round current clamp about 185g×3, test line about 250g
Test Line Length1.5m
Current Clamp Length2m×φ5mm
Working Temperature and Humidity-10C40C; below 80%Rh
Storage Temperature and Humidity-10C~60C; below 70%Rh
Input ImpedenceTesting voltage the input impendence is 2MΩ
Withstand VoltageWithstand 1000V/50Hz sine wave AC voltage for 1 minute between the meter lines and shell; Withstand 500V/50Hz AC voltage sine wave for 1 minute between the two voltage inputs
Insulation≥100MΩ between meter lines and shell or between the two voltage inputs
StructureDouble insulation, with insulation vibration-proof sheath
Safety SpecificationsIEC61010-1 CAT III 600V, IEC61010-031, IEC61326, 2 class of pollution
AccessoriesMain Unit: 1 pc; Meter Box: 1 piece; Current Clamp: 3 pcs; Test Line: 4 pcs(2 yellow, 2 black); RS232 Data Line: 1 pc; Disk: 1 pc; Battery: 6 pcs(alkaline drybattery: 1.5V AA); User Manual: 1 pc ; Guarantee Card: 1 pc; Certification: 1 pc.

 

 

Packaging & Shipping

 ETCR4200A Intelligent Double Clamp Digital Phase Volt-Ampere Meter

 

Company Information

 ETCR4200A Intelligent Double Clamp Digital Phase Volt-Ampere Meter

 

 

 

Contact Supplier

Ms. Ada ZIBOO Director Chat Now
Telephone
0086-532-88900998
Mobile
18653223561
Address
HongKong East road Qingdao,Shandong