ETCR4800 oil pumping Multimeter / Patrol Tester / petroleum special instruments
USD $659.18 - $659.18 /Set
Min.Order:1 Set
Qingdao Zhibohongyu Trading Co., Ltd.
Function | Simultaneous measurement of electrical parameters field : between AC current , voltage, frequency , voltage and current phase , pass off resistance , maximum current pumping up and down stroke , stroke ratio, up and down stroke time , strokes per minute |
Power source | DC7.2V ( section 1.2V 6 5 number can be rechargeable battery ) |
Jaw size | Round lip current clamp : 35mm × 40mm |
Range | Voltage : AC 0V ~ 700V |
Current : AC 0.0mA ~ 300A | |
Phase : 0 ~ 360 | |
Resistance : 0.00Kohm ~ 20.0Kohm | |
Frequency : 10.0Hz ~ 70.0Hz | |
Resolution | Voltage : AC 1V |
Current : AC 0.1mA | |
Phase : 1 | |
Resistance : 10ohm | |
Frequency : 0.1Hz | |
Accuracy | Voltage : (1.5% rdg + 3dgt) |
Current : (1.5% rdg + 3dgt) | |
Phase : 3 | |
Resistance : (2.0% rdg + 3dgt) | |
Frequency : (2.0% rdg + 3dgt) | |
Measured phase frequency amplitude | Voltage : 30V ~ 700V |
Current : 30mA ~ 300A | |
The number of wells No. | No. 100 |
Data Storage | 1000 group |
RS232Interface | RS232 interface , uploading computer stored data to facilitate analysis and management of data through software editing pound |
Communication lines | 1.8 m RS232 communication lines , long |
Well number setting | 15 code , you can edit the PC software instrument or pound sign |
Clock function | There is |
Password Settings | There , six digit password |
Backlight function | There are , for dark places and at night, do not operate the instrument backlighting turns off automatically after 3 minutes |
Automatic shutdown | Within 15 minutes after boot does not operate the meter will automatically shut down |
Power consumption | The maximum power consumption of 50mA backlight turned on |
30mA backlight off power meter | |
Display Mode | LCD display , 240dots × 160dots |
Meter size | Long generous : 196mm × 92mm × 54mm |
DetectionRate | About 2 seconds / time |
Battery voltage | Meter time display battery voltage, when the battery voltage is lower than 6.5V, low battery symbol appears , please charge |
Instrument Quality | About 1kg ( including attachments ) |
Test line length | 1.5m |
Current Clamp Cable Length | 2m × 5mm |
Working temperature and humidity | -20 ~ 40 ; 80% Rh or less |
Storage Temperature and Humidity | -10 ~ 60 ; 70% Rh or less |
Input impedance | Test voltage input impedance is : 2M |
Resistance to pressure | Meter line and shell tolerance between 1000V / 50Hz sine wave AC voltage lasted 1 minute |
Insulation | 100M meter line between the shell and jacket |
Structure | Double insulation , vibration-proof jacket with insulation |
For Safety | IEC61010-1 CAT 600V, IEC61010-031, IEC61326, pollution degree 2 |
Random Accessories | Host: 1 ; current clamp : 1 ; test line : 4 ; RS232 data lines : 1 ; Software CD : 1 ; meter box : 1 ; Charger: 1 ; Rechargeable Battery : 6 ( 1.5 V 5 numbers) |