Master series water purification system
Features and functions
Control system | Microprocessor, multi-menu operating. |
Display system | 240×128 graphical LCD display, real-time cartoon type working mode display. |
Quality monitor | 3-way on-line sensor, detecting the quality of feed water, RO water and ultrapure water respectively |
Visual and auditive alarm | Multiple alarm-including inlet water over standard, no water, full water, outlet water over standard, consumables’ life-span ends, malfunction auto-detect, guaranteeing safety. |
Recirculation system | The system circulates to maintain ultrapure water’s quality when the system is not in use |
Safety system | With factory and clients’ two kinds of password, every system setting can be protected, avoiding unauthorized operation. |
Consumable-replacing remind | The life-span can be set and the time used and left can be displayed, replacing auto-reminding, avoiding the decline of water quality. |
Sanitization system | Ultrapure water pipeline can be regularly disinfected to keep a high quality water. |
RO membrane flush | Self-maintenance of the reverse osmosis membrane. |
“On-off duty” mode | On duty means the display is working, off duty means the display is not working. |
Water tank | Different tanks to meet every need and assure ample water-supply. |
Machine case | Human engineering design, streamline case. Molding process, high-strength plastic shell |
Pipeline and adaptor | Pipeline with NSF authorization to assure high quality ultrapure water, new easy-inserting adaptor to make convenience of cartridge maintaining and replacing. |
Pretreatment cartridge | Ultra long-life pre-cartridge, 6-8 times of normal active carbon (expect PP filter), the life-span is 1 year, reducing the working cost furthest. |
RO membrane | Manufactured by DOW or FCS, realize the combination of long-life and high-quality. |
Ultra purification cartridge | 4 cartridges of ultra purification, using famous nuclear resin to assure best quality. |
UV module | Built-in 185 and 254 nm UV lamp, ensure the water is free of TOC (Optional). |
UF module | MWCO 5000D PES UF module, effectively eliminating endotoxin, can be used for precise cell cultivating and IVF (Optional) |
Terminal filtration | high-speed and large flux (0.45+0.1) µm polyether alternative compound filter terminal disinfection filter, assuring the quality absolutely axenic |
Master series products
n Master-Q deionized pure water system (Tap water inlet)
n Master-S ultra pure water system (Tap water inlet)
n Master-D ultra pure water system (pure water inlet)
n Master-Q series deionized pure water system (Tap water inlet) | |||||
Model | Deionized water purification system | ||||
Master-Q | Master-Q UT | Master-Q plus | Master-Q plus UT | ||
Flow procedure | PF+KDF+AC+RO+AC+DI | PF+KDF+AC+RO + UV+AC + DI +TF | PF+KDF+AC+RO+AC+DI | PF+KDF+AC+RO + UV+AC + DI +TF | |
Application | Ware washing, Agricultural expe, General biological expe, Aquatic products feeding, Inlet water for Ultra pure water machine, Inlet water for sterilizer/T&H chamber, Buffer disposing, Aseptic drinking water, Physical and chemical analysis, Fine chemistry industry, Inlet water for Ultra pure water machine, GC/HPLC, Pharmacy research, Medicine examining | ||||
DI water quality | Resistivity | 16-18.2MΩ.cm | |||
Heavy metal ions | 0.1ppb | ||||
TOC | 30 ppb | ||||
Bacteria | - | 1CFU/ml | - | 1CFU/ml | |
Particle(>0.22μm) | - | 1/ml | - | 1/ml | |
RO water quality | < TDS(ppm, mg/l) of tap water×5% | ||||
Technical specification | Output(25℃) | 15 Liters/hour* | 30 Liters/hour | ||
Flow rate | 2 Lliters/min(with pressure tank) | ||||
Pure water outlet | RO water, deionized water | ||||
Dimension/weight | Length×Width×Height:50×36×54cm / 20-30Kg | ||||
Electric requirements | AC110-220V,50/60Hz,120W | ||||
Control system | Mode display | Power on, program, inlet rinse, producing, full, circle, regular outlet, disinfection, consumables replacing remind | |||
Safety | Low pressure and full water alarm, password, auto-reset, outlet forbidden when alarm or disinfection | ||||
System monitor | Display quality of feed water, RO water and ultrapure water, temperature, used and left time of consumables | ||||
Feed water requirements | Tap water, inlet TDS<200 ppm,5-45℃,1.0-4.0kgf/cm2 (if inlet TDS>200ppm, extra pretreatment is recommended) | ||||
Purification system | Pretreatment unit | 5μm spun fiber filter×1+Kinetic degradation fluxion filter×1+Granular active carbon filter×1 | |||
RO unit | 100 GPD RO membrane×1 ( Plus model: 100 GPD RO membrane×2) | ||||
Subsequent unit | Post active carbon filter×1+Mixed bed resin cartridge×3{Plus model: Mixed bed resin cartridge×4} UT model:+254nm wavelength UV lamp cartridge×1+(0.45+0.1) μm terminal filter×1 | ||||
Standard configuration | Main body(including:1 set cartridge)+4 gallon tank+ accessory box |
n Feed water :TDS=200ppm, 25℃, 50psi and 15% recovery rate.
n GPD=gallon per day, 1gallon=3.78L.
n The quality of feed water will influence outlet water quality and cartridge’s life.
n PF: Pretreatment, KDF: Kinetic degradation fluxion, AC: Active carbon, RO: Reverse osmosis, DI: Deionization, UV: UV lamp, TF: Terminal filter