High temperature test chamber environmental equipment

Brand Name Zhongkemeiqi
Place of Origin Tianjin, China
Model Number MQ-T100F-2
Power Electronic
Usage High temperature testing

Product Features

 

 Product Show: 

 

High temperature test chamber environmental equipmentHigh temperature test chamber environmental equipmentHigh temperature test chamber environmental equipmentHigh temperature test chamber environmental equipmentHigh temperature test chamber environmental equipment

 

 Product Advantages: 

 

High temperature test chamber environmental equipment

 

 Product Process: 

 

High temperature test chamber environmental equipment

 

 Product Parameters: 

 

High and low temperature test chamber

Product Usage:

High and low temperature test chambers are widely used in aviation, aerospace, electronics, instrumentation, electrical products, materials, automotive parts, plastics and rubber products, chemicals, building materials, medical, photovoltaic and other industries.They test the temperature stress, temperature aging screening, reliability testing, performance testing, weathering test, high temperature storage of test pieces under high temperature and environmental conditions.

 

Implementation and meeting standards:

GB/T 10589-2008: cryogenic test chamber technical conditions

GB/T 10592-2008: high and low temperature test chamber technical conditions

GB/T 2423.1-2008: low temperature test method

GB/T 2423.2-2008 : high temperature test method

GB/T 2423.22-2008: temperature change rate test method

GJB 150.3A-2009: high temperature test method

GJB 150.4A-2009: low temperature test method

GJB 360B-2009: test methods for electronic and electrical components

JJF 1101-2003: environmental and test equipment temperature and humidity calibration specifications

GB/T 5170.2-2008: test method for environmental test equipment of electric and electronic products temperature test equipment

Product features:

New type of refrigeration: compressor refrigeration can achieve any temperature from -70°C to -170°C

Efficient and energy-saving: reduce power consumption by more than 30% during low temperature test

Excellent performance: performance indicators better than national and military standard requirements

Compact size: easy access to the laboratory within 500 liters, saving floor space

Optimize the air duct: based on the professional CFD fluid mechanics design, the air circulation is more reasonable

Simple operation: user-friendly operation interface, one-stop start-up, no professional training

Multiple Protection: ensure the safety of personnel, test pieces and equipment, worry-free use

 

Technical indicators:

product name

High and low temperature test chamber

Product number

MQ-T100F-2

MQ-T250F-2

MQ-T500F-2

MQ-T1000F-2

Nominal volume

unit/L

100

250

500

1000

Inner size

Width × depth × height (mm)

450×450×500

600×600×700

750×750×900

1000×1000×1000

External size

Width × depth × height (mm)

650×1000×1450

800×1200×1700

950×1400×1900

1200×1500×1950

Performance

Temperature range

A,-40℃~150℃   B,-70℃~150℃  C,-90℃~150℃  D,-120℃~150℃

Temperature fluctuation

±0.5℃

Temperature uniformity

≤2.0℃

Temperature deviation

≤±2.0℃

Heating rate

≥2.0℃/ Min

Cooling rate

≥2.0℃/ Min

Linear temperature control

0.5~1.0℃/Min

Refrigeration method

Compressor refrigeration

Cooling method

Air-cooled

The main components

Control System

Siemens programmable controller + touch screen + independent development program

Heating system

Fully independent system, high efficiency stainless steel finned tube heater

Cooling System

Importer-type scroll compressor

Circulatory system

Temperature and low noise motor, stainless steel centrifugal impeller

Use materials

Carton material

High-quality carbon steel plate, phosphating electrostatic spray treatment

Inner box material

International standard SUS304# stainless steel mirror treatment

Insulation material

Hard flame retardant polyurethane foam

Sealing material

High and low temperature environment-friendly silicone rubber seal

voltage

380±10% VAC,50Hz,3L+N+G

Communication Interface

RS232 communication interface, USB data interface

Standard configuration

Sample holder 1 set, test lead hole 1 set

Optional accessories

Recorder, Remote Control Software, Insulated Sample Holder, Split Manipulator, Dry Air Purge

safety devices

Leakage, short circuit, motor overheating, heater overheating, compressor overpressure, overload, multiple overtemperature protection

Environmental requirements

Ambient temperature: 5~35°C, relative humidity: ≤85%RH, no strong vibration, electromagnetic radiation, no dust and corrosive substances around

Note:

1.temperature performance parameters are in the ambient temperature of 25 °C, studio no load conditions, in accordance with GB/T5170.2-2008 test;

2. according to the specific requirements of users customized non-standard high and low temperature test box;

3. This technical information is subject to change without notice.

 

High and low temperature test chamber common fault solution

 

1, the temperature drops below the preset value or can not cool down

(1) The compressor is damaged or not opened, replace the compressor and check the compressor circuit and control components for damage.

(2) Refrigerant leakage, use nitrogen leak detection method to find the leak point, weld, vacuum, add refrigerant, re-commission

(3) Solenoid valve is abnormal, replace the solenoid valve, check the solenoid valve control circuit

(4) Capillary clogging, replacing the capillary, replacing the dry filter, blowing the condensing system impurities with nitrogen, adding refrigerant debugging

(5) The condenser freezes, heats up the moisture in the tank, and then cools down.

2, the temperature rises below the preset value or can not heat up

(1) The heating tube is damaged, and the heating tube is replaced.

(2) Solid state relay is damaged, replace solid state relay

3, the humidity does not reach the preset value or can not humidify

(1) The humidification pipe is damaged, and the humidification pipe is replaced.

(2) The water level float that controls the humidification does not float

(3) Humidification solid state relay is damaged, replace the humidification solid state relay

4, humidity always shows 100% RH

(1) Abnormal gauze, change gauze

(2) Failure of the refrigeration system, check the refrigeration system

(3) Abnormal water supply in the waterway system, check the water system

5, the main power switch trip

(1) The total power of the equipment exceeds the total current of the power switch, and the appropriate power switch is replaced.

(2) Leakage of equipment, check compressor, motor, heating pipe, humidification pipe, condenser, fan, transformer, switching power supply, water pump and other components, insulation resistance and leakage current

6, leaking water

(1) Check whether the water pipe, water cup, humidifying bucket and water tank are normal. If there is any abnormality, use the raw material tape for inspection or seal with high temperature resistant neutral glass glue.

(2) Check whether the seal inside the box is normal, if there is abnormality, seal with high temperature resistant neutral glass glue.

(3) Check whether the refrigeration system is normal. If there is any abnormality, use insulation cotton to wrap the insulation.

7. Frost or ice in the box

(1) Long-term operation of low temperature causes the temperature to cool after drying at high temperature

(2) When the test is carried out, the door is often opened, and the door is not opened or opened as much as possible during the test.

(3) The circulating motor is damaged or the wind wheel is removed, the circulating wind wheel is replaced and the wind wheel is tightened.

8, the equipment is noisy

Detect the motor, wind wheel, condenser, fan, compressor, casing cover, etc.

 

 Related Products: 

 

 

Click the pictures for detail product info

 

High temperature test chamber environmental equipment

 

 Packing & Delivery: 

 

High temperature test chamber environmental equipment

 

 About Us: 

 

Zhongkemeiqi (Tianjin) Technology Co., Ltd, which is a high-tech enterprise specializing in the research, development, production and sales of many kinds’ climatic chambers.

We have passed the ISO9001 quality management, and our team consists of several senior experts who have been engaged in the development, manufacture and maintenance of environmental test equipment for many years.

Temperature and Humidity test chamber,
Rapid Temperature Change test chamber,
Thermal Shock test chamber,
Temperature and Low-Pressure test chamber,
Temperature Humidity and Vibration test chamber;
Ultra-Low Temperature Chamber /Solution,
Aging test chamber (UV, Xenon lamp, Ozone) ,
Rain / Sand Dust test chamber,
Vacuum drying oven, …

High temperature test chamber environmental equipment

 

 Factory Display: 

 

High temperature test chamber environmental equipmentHigh temperature test chamber environmental equipment

 

 Our Certificates: 

 

High temperature test chamber environmental equipment

 

 FAQ: 

 

Q1: How can i get a quotation?

A1: Kindly provide us your details request (inner chamber size, temperature range, humidity range, power supply, product, etc.), leave us an inquiry or email and we will response promptly!

Q2: What's your temperature & humidity range?
A1: Our standards temperature range is -70℃~+180℃, 20%~98%RH.
We also can do Ultra low temperature to -190℃ .

Q3: What's your rate of heating & cooling?
A3: Our standards rate is average 3℃/min for heating, 2℃/min for cooling.
3℃/min,5℃/min,8℃/min,10℃/min,15℃/min linear or non-linear speed is available for us.

 

Q4: What's your warranty?
A4: 12 Months (Noted: free spares parts can be offered during warranty period, exclude consumables and man-made damages), life-time technical service

 