Product Details

6VDC; 250VAC 3A Electronic Components HK4101F-DC12V-SHG

Brand Name HONGFA
Place of Origin China
Model Number HK4101F-DC12V-SHG
Size Miniature
Usage General Purpose
Contact Load Low Power
Protect Feature Epoxy
Theory Electromagnetic Relay

Product Features

Mfr. #: HK4101F-DC12V-SHG

 

Safety Standard: C-UL CQC TUV

 

Contact Specification:

 

Contaact Gap: 0.3mm Minimum

 

Contact Resistance:

Maximum 100mΩ at initial value. Test Current: 1A, Open Circuit Test Voltage: 6VDC. By using Voltage Drop Metho

 

Contact Capacity:

3 Amps at 250VAC Cosφ=1. 3 Amps at 30V

 

Coil Specification at

20 °C:

Rated Voltage: 12VDC.

Nominal Current: 12.5/16.7/30

Rated Power

Consumption:  0.15W/0.2W0.36W

 

Coil Resistance: 960/720/400

 

Pull In Voltage:

≦ (Contact operating voltage when voltage is gradually applied. It is 80%

of the Rated Voltage) V DC

 

Drop Out Voltage: ≧ (Contact breaking voltage when rated voltage is gradually reduced. It is

10% of the Rated Voltage) VDC

 

Max. Allowable

Voltage:

(130% of the Rated Voltage) V DC

 

Operate Time: 6 milliseconds Maximum when rated Voltage is applied.

 

Release Time: 4 milliseconds Maximum when rated Voltage is suddenly cut off.

 

Coil Temperature

Rise: 40℃ Maximum. Maximum Allowable Voltage is applied to Coil while no load should be applied

to Contacts, then the temperature should be measured when the value is

stabilized. Environment temperature should not be included in.

 

Electrical

Characteristics:

 

Life Expectancy:

 

Electrical Life: 100,000 operations Minimum at 3A/250VAC Cosφ=1. 100,000 operations Minimum at3A/30VDC

Rated Voltage is applied.

 

Mechanical life: 10,000,000 operations Minimum at No Load condition.

 

Maximum

Operating

Frequency: Electrical: 30 operations/minute. Mechanical: 300 operations/minute.

 

Dielectric Strength:

Between

Contacts: 500VAC at Test Frequency 50/60 Hz, Leakage Current: 1mA for 1 minute.

 

Between Coil &

Contact: 1,000VAC at Test Frequency 50/60 Hz, Leakage Current: 1mA for 1 minute.

 

Insulation

Resistance: ≧100 MΩ Minimum. A Voltage of 500VDC should be applied after which measurement shall be

made.

 

Vibration:

Endurance I:  The Coil shall be maintained under not energized condition, double amplitude

1.5 mm, the entire frequency range changes from 10 to 55 Hz then returns to

10 Hz shall be made in 1 minute. This motion shall be applied for a period of

2 hours in each of 3 mutually perpendicular axis (a total of 6 hours) There

should not be any deformations in construction and in appearance, while the

Electrical Specifications should be fulfilled after the test.

 

Endurance II

(Error

Operation): The Coil shall be maintained under energized condition, double amplitude 1.5

mm, the entire frequency range changes from 10 to 55 Hz then returns to 10

Hz shall be made in 1 minute. This motion shall be applied for a period of 5

minutes in 3 mutually perpendicular axis. Malfunction is not allowed during

the test (contact breaking time should be less than 1 millisecond) In addition,

there should not be any deformations in construction and in appearance while

the Electrical Specifications should be fulfilled after the test.

 

Shock:

 

Endurance I:

 

Peak Acceleration: 1000m

The Coil shall be maintained under not energized condition, 5 successive

shocks shall be applied in 3 mutually perpendicular axis. There should not

be any deformations in construction and in appearance while the Electrical

Specifications should be fulfilled after the test.

 

Endurance II

(Error

Operation): Peak Acceleration: 100m/s²

 

The Coil should be maintained under energized condition, 2 successive

shocks shall be applied in 3 mutually perpendicular axis. Malfunction is not

allowed during the test (contact breaking time should be less than 1

millisecond) In addition, there should not be any deformations in construction

and in appearance while the Electrical Specifications should be fulfilled after

the test.

 

Environmental

Characteristics:

 

Temperature Range:

 

Operating

Temperature

Range:

  Operating temperature range is the range of ambient temperature of which the

Relay can be operated continuously within operative voltage range of coil (no

condensation of water drops under low temperature condition)

 

Storage

Temperature

Range: Storage temperature range is the range of ambient temperature of which the

Relay can be stored without damages (no condensation of water drops under

low temperature condition). Conditions are as specified elsewhere in these

specifications

 

Humidity Range: 35~85% RH.

 

Cold Resistance:

Cold

Resistance in

Use: Relay should be kept in temperature chamber at -30 ± 2°C for two hours that

no current or voltage shall be supplied to Relay. Such condition shall be

maintained while the rated voltage is supplied to Relay, then the Relay shall

operate normally. (No condensation of water drops under low temperature

condition)

 

Storage Cold

Resistance:  Relay should be kept in temperature chamber at -40 ± 2°C for 72 hours. Then the Relays shall be maintained at standard atmospheric condition for 1

to 2 hours after which measurement shall be made. Construction, Relay

operation, Insulation Resistance and Dielectric Strength shall satisfy the

specification requirements. (No condensation of water drops under low

temperature condition)

 

Heat Resistance:

Heat

Resistance in

Use: Relay should be kept in temperature chamber at 70 ± 2°C for two hours that

rated Voltage should be supplied to Coil while rated Current should be

supplied to Contacts. Such condition shall be maintained while the rated

voltage is supplied to Relay, then Relay shall operate normally.

 

Storage Heat

Resistance: Relay should be kept in temperature chamber at 70 ± 2°C for 16 hours. Then

the Relays shall be maintained at standard atmospheric condition for 1 to 2

hours after which measurement shall be made. Construction, Relay

operation, Insulation Resistance and Dielectric Strength shall satisfy the

specification requirements.

 

Moisture

Resistance: Relay should be kept in temperature chamber at 40 ± 2°C (90~95% RH) for 48

hours. Then the Relays shall be maintained at standard atmospheric

condition for 1 to 2 hours after which measurement shall be made. Construction, Relay operation, Insulation Resistance, Dielectric Strength shall

satisfy the specification requirements.

 

Terminal Strength: A load of 300g should be applied to the Terminal for one minute in horizontal

direction. There should not be any looseness or bending of Terminals.

 

Soldering Dip Test: The front 3 mm of Terminal should be immersed for 3 ± 0.5 seconds at 230 ±

5°C. Soldered area must be minimum 90% of the soldering surface.

 

Soldering Heat Resista

Approx.10gnce: When the Terminal are immersed into soldering bath at 350 °C for 3 seconds,

the Relay shall satisfy all electrical and mechanical specifications and must

not have excessive change in outside appearance.

 

Weight: Approx.3.5g

 

Sample Test Method: GB2828-2000 Level – General II, AQL 0.4

 

Factory Pack Quantity: 25

 

Price: 0.4-0.5