Product Details

Gold Testing Machine Price XRF Analizador

Brand Name Drawell
Place of Origin Shanghai, China

Product Features

Product Description
Instruction
DW-NP-5010A energy dispersive XRFhas very wide application. It can do qualitative, quantitative and no sample analysis. Such as block sample, powder or liquid samples, from the 4th element in the periodic table beryllium (Be) to the 92rd element uranium (U), almost all of the elements can be accurately analyzed. The analytical concentration range can be from 0.1 PPM to 100%, and even up to 100% of the elementconcentration can be directly measured without dilution.XRF analysis method has the advantages of simple sample preparation, wide determination range of elements, high determination accuracy, good reproducibility, fast measurement speed (30s-900s), no environmental pollution and no destruction of samples.

Working principle The original X-ray produced by X-ray tube and high voltage is irradiated on the sample after being properly filtered by the optical filter. The characteristic X-ray (called X-ray fluorescence) of the elements contained in the sample is stimulated. X-ray fluorescence spectra were obtained by using X-ray detectors with high energy resolution. Different elements formed different spectral peaks on the spectra.The strength of the spectral peak is directly proportional to the content of elements in the sample. The energy spectrum detected by the detector is analyzed by the computer. The types of elements contained in the sample are qualitatively analyzed by the position and shape of the spectral peak.

Application DW-NP-5010A energy dispersive X-ray fluorescence spectrometer (XRF) is widely used in environmental protection, geology, mineral, metallurgy, cement, electronics, petrochemical, polymer, food, medicine and high-tech materials and other fields, playing an important role in product research and development, production process monitoring and quality management.In addition, the instrument can be used in archaeology, building materials, RoHS directive and other industries. It is the enterprise quality control ideal choice.
Features
Main component and technical parameters
1. Si(PIN) or SDD detector The resolution of detector is one of the main indexes to evaluate the performance of energy dispersive XRF spectrometer.   Resolution<  145eV (The lower the resolution, the higher the sensitivity.) Counting rate>  1000/S Crystal area>  15mm2 Beryllium window thickness  =  0.025mm Detector power<  1.2W   2.  Multi-channel analyzer Number of channels: 2048 channels   3 Power controller System power control: +5 VDC at 250 mA (1.2 W) Constant cooling control: 400 VDC   4.  X ray tube The X-ray tube, specially treated with embedded lead inside is shielded in full range, leaving only the side window for the x ray outlet. The canned insulating oil is used for high voltage insulation and cooling, 0.005 inch Beryllium window, rated consumption power 50W, rated power 50kV. Designed service life >15000h.   5.  High voltage generator Input:  85~265VAC,47~63Hz,Power factor correction. 1kV~5kVcomply to UL85~250VAC input standard   Voltage variation: 0.01% of output voltage from no load to full load Current variation: 0~rated power, 0.01% of output current   Ripple: Peak - peak of output voltage 0.25%   Temperature variation: voltage or current setting, 0.01%/oC   Stability: 0.05%/8h after warming-up for half an hour

6.  Automatic filter conversion system Filters are automatically selected and converted(filter function:The energy spectrum component of the excitation line can be improved to suppress the strong X-ray fluorescence of high content components and improve the measurement accuracy of the elements to be measured.)   7.  Radiation shielded system Ø Newly designed and specially treatedX-ray tube with low-radiation Ø Fully enclosed lead plate double shield design Ø Automatic filtering device for lead plate Ø X - ray interrupters in case of sample unexpected cover opening Ø Delay testing and X-ray warning system   8.  The detection limit of harmful elements Cd, Pb, Cr, Hg and Br is restricted according to ROHS instruction Detection limit (Cd、Pb、Cr、Hg、Br): 2ppm   9.  Powerful analysis software workstation   One-touch operation software, simple and easy to use, user does not need professional knowledge.   Ergonomic human-machine interface   Operators do not need to set various test parameters, powerful customized report function..   Test data is automatically stored with historical query function   The most advanced qualitative and quantitative analysis method.   Dozens of elements can be analyzed simultaneously.

Specification
Model
DW-NP-5010A
Analysis principle
Energy dispersive X-ray fluorescence analysis
Element measuring range
Any element from Na(11)-U(92)
Min. measuring limit
Cd/Hg/Br/Cr/Pb≤2 ppm
Sample shape
Arbitrary size, any irregular shape
Sample type
Plastic/metal/film/powder/liquid etc
X ray tube
Target
Mo
Tube voltage
5─50KV
Tube current
1─1000uA
Sample exposure diameter
2, 5, 8mm
Detector
Si-PIN or SDD detector, high speed pulse height analysis system
High voltage generator
Special HV generator for X fluorescence
ADC
2048 channels
Filter
6 filters are automatically selected and converted.
Sample observation
200×color CCDcamera
Analysis software
Patented software products, free upgrade for life
Analysis method
Theoretical α coefficient method,basic parameter method, empirical coefficient method
Analysis time
30-900seconds, adjustable
Operating system software
WINDOWS XP
Dataprocessing system
Host
PC business model
CPU
≥2.8G
Memory
≥2g
CD-ROM
8xDVD
Hard disk
≥500G
Display
22’’ or 24’’ LCD display
Working environment
Temperature 10-35С,humidity 30-70%RH