gold testing machine price xrf analyzer
USD $13,600 - $14,150 /Piece
Min.Order:1 Piece
Chongqing Drawell Instrument Co., Ltd.
Ø Performance Features
1. Small, light and easy to carry.
2. High-speed processing chip, advanced algorithm and high-responsive software, resulting in even faster analysis.
3. High-performance X-ray Tube, Ultra-high Resolution Detector combined with Digital Multi-channel Processing Technology, yielding super-high detection resolution.
4. Indicator lights flash on both sides for safety purposes during measurement, i.e., the built-in double beam technology will automatically sense whether there is a sample at the measurement window.
5. Industrial resistive touch screen, superior to capacitor screen in back-light and clearer against sunlight in the field. At the same time, people don't need to take off gloves when they are opreating machine in some particular environment.
6. TrueX utilizes anti-slip, abrasion resistance and streamlined design, which is light and easy to carry. It also integrates the new high speed digital multi-channel technology, the new library grade base identification system and the super-FP algorithm. These features allow it to measure elements faster, with higher accuracy and greater repeatability.
7. Intelligent battery management exerts a real-time monitoring of the residual capacity of battery and backup battery through MSBUS bus.
8. Automatic switch to standby mode when not used and recovery after the machine is picked up, which saves power and extends working time; moreover, TrueX has a gravity sensing system which shuts down instrument automatically when it accidentally falls down, another safety consideration; TrueX will also give out alarm when ambient temperature or humidity exceeds the scope of application.
9. TrueX adjusts air pressure factor automatically based on altitude it has detected. This function increases excitation effect of light elements by 40% and that of rare earth elements by 30%.
10. On TrueX, users can customize the reports by adding their company logos, addresses, test results, spectrum and others (such as product description, origin of products and batch number).
11. TrueX is built with double beam technology which can automatically sense whether there is a sample at the measurement window. This is also a safety and protection feature. The brightness of the display of TrueX is automatically regulated according to environment brightness.
12. TrueX can be configured and maintained in a remote way via Internet.
13. TrueX can build a three dimensional element content distribution graph allowing for a fast estimate of mineral reserves or the extent of geological disaster with the built-in GPS for latitude and longitude reading combined with a 3rd party GIS analysis software.
14. TrueX's new algorithm optimizes the spectral resolution, so lower detection limits can be achieved, which are comparable with even large-scale lab instruments.
15. TrueX Ultra-short optical™ path design can significantly improve light element excitation effects,
without the fall/fill condition.
Radiation Safety Guarantee
Low power (4W) X-ray tube, mini collimator reduce radiation quantity effectively;
X-ray tube radiation protection shield avoids X-ray escape;
The structure producing radiation is all in equipment interior, you don't need to align or calibrate X ray, then ensure not detect any measurable radiation in equipment operation process;
X ray indicator light alarms user the radiation produciton;
Independent safe circuit and DoubleBeam interlock tool can protect user safety effectively;
Conform to dosage limit requirement in <Radiation protection standards for X-ray diffraction and fluorescence analysis equipment> (GBZ115-2002);
Conform to valid annual dosage limit requirement for workers and public in<Ionizing Radiation Protection and Safety of Radiation Sources basic standards> (GB18871-2002);
Monitoring results:
Point No. |
Point Discription |
Testing Results (μSv/h) |
Device State |
|||||
1 |
2 |
3 |
4 |
5 |
Average |
|||
1 |
5cm above the surface of the device |
0.10 |
0.11 |
0.12 |
0.10 |
0.09 |
0.10 |
Turn On |
2 |
5cm the surface left of the device |
0.10 |
0.12 |
0.10 |
0.11 |
0.12 |
0.11 |
Turn On |
3 |
5cm the surface right of the device |
0.10 |
0.12 |
0.10 |
0.11 |
0.13 |
0.11 |
Turn On |
4 |
5cm below the surface of the device (holding place) |
0.12 |
0.10 |
0.10 |
0.11 |
0.12 |
0.11 |
Turn On |
5 |
5cm back the surface of the device |
0.09 |
0.08 |
0.10 |
0.12 |
0.08 |
0.09 |
Turn On |
6 |
Operation place |
0.10 |
0.09 |
0.11 |
0.08 |
0.09 |
0.09 |
Turn On |
7 |
Public Distance Zone |
0.09 |
0.05 |
0.07 |
0.08 |
0.06 |
0.07 |
Turn Off |
Note: the testing result doesn’t deduct radiation background value.