Product Details

19/3.18 Mulberry Aaac Conductor All Aluminum Alloy Concentric Cable Factory Direct Price

Product Features


19/3.18 Mulberry Aaac Conductor All Aluminum Alloy Concentric Cable Factory Direct Price
Products Description
KINGYEAR Cable is one of the leading cable products production enterprise in China,our mainly products are electric wire,power cable, control cable,bare conductor (AAC/AAAC/ACSR),ABC overhead cable.
AAAC-Aluminum Alloy Overhead Bare Conductor is mainly used as bare overhead transmission cable and as primary and secondary distribution cable. It is also suitable for laying across basins, rivers and valleys where special geographical teatures exist.
Product parameters
Duplex service drop
Code Name
Phase conductor
Bare Neutral Message
Nominal Weight ( kg/km )
Allowable Ampacity
Size & No.of wires
Insulation Thick(mm)
Nominal Diameter (mm)
Size & No.of wires
Rated Strength (kg)
XLPE
Aluminum
( A )
Bare
OD
AAC
Pekingese
6-Solid
1.14
4.1
6.4
6-7
255
20.8
72.9
78
Collie
6-7
1.14
4.6
6.9
6-7
255
23.8
72.9
78
Cocker
6-7
1.52
4.6
7.7
6-7
255
32.7
72.9
78
Dachshund
4-Solid
1.14
5.2
7.5
6-7
400
26.8
114.6
103
Spaniel
4-7
1.14
5.9
8.2
6-7
400
29.8
116.1
103
Cairn
4-7
1.52
5.9
8.9
6-7
400
40.2
116.1
103
Doberman
2-7
1.14
7.4
9.7
2-7
612
38.7
184.5
136
Airedale
1-19
1.52
8.4
11.5
1-7
-
56.5
233.6
158
Basset
1/0-7
1.52
9.3
12.4
1/0-7
903
64
294.7
182
Malemure
1/0-19
1.52
9.4
12.5
1/0-7
903
64
294.7
182
AAAC
Chihuahua
6-Solid
1.14
4.1
6.4
6-7
499
20.8
72.9
78
VIzsla
6-7
1.14
4.6
6.9
6-7
499
23.8
72.9
78
Harrier
4-Solid
1.14
5.2
7.5
4-7
798
26.8
116.1
103
Whippet
4-7
1.14
5.9
8.2
4-7
798
29.8
116.1
103
Schnauzer
2-7
1.14
7.4
9.7
2-7
1270
38.7
184.5
136
Afghan
1/0-7
1.52
9.3
12.4
1/0-7
2023
64
296.1
182
Hocler
1/0-19
1.52
9.4
12.5
1/0-7
2023
64
296.1
182
ACSR
Setter
6-Solid
1.14
4.1
6.4
6/6/01
540
20.8
72.9
78
Shepherd
6-7
1.14
4.6
6.9
6/6/01
540
23.8
72.9
78
Retriever
6-7
1.52
4.6
7.7
6/6/01
540
32.7
72.9
78
Eskimo
4-Solid
1.14
5.2
7.5
4/6/01
844
26.8
114.6
103
Terrier
4-7
1.14
5.9
8.2
4/6/01
844
29.8
116.1
103
Yorkshirc
4-7
1.52
5.9
8.9
4/6/01
844
40.2
116.1
103
Chow
2-7
1.14
7.4
9.7
2/6/01
1293
38.7
184.5
136
Labrador
1-19
1.52
8.4
11.5
1/6/01
1610
56.5
233.6
158
Bloodhound
1/0-7
1.52
9.3
12.4
1/0-6/1
1987
64
294.7
182
Bull
1/0-19
1.52
9.4
12.5
1/0-6/1
1987
64
294.7
182
Applications of Duplex ABC cable
To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75°C maximum.
Applications of Triplex ABC cable
To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volt or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene insulation 90°C maximum for crosslinked insulation.
Applications of Quadruplex ABC cable
Used to supply 3 phase power, usually from a polemounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulation 90°C maximum for crosslinked polyethylene(XLPE) insulated conductors
IEC 61089
Code Name
Nominal
No./Nominal
diameter of
wires
Approximate
Overall
Diameter
Approximate
Weight
Nominal
Breaking
Load
Nominal DC
Resistance
at 20°C
mm2
No./mm
mm
kg/km
KN
ohm/km
10
10
7/1.35
4.05
27.4
2
2.8633
16
16
7/1.71
5.13
43.8
3
1.7896
25
25
7/2.13
6.39
68.4
4.5
1.1453
40
40
7/2.70
8.1
109.4
6.8
0.7158
63
63
7/3.39
10.17
172.3
10.4
0.4545
100
100
19/2.59
12.95
274.8
17
0.2877
125
125
19/2.89
14.45
343.6
21.3
0.2302
160
160
19/3.27
16.35
439.8
26.4
0.1798
200
200
19/3.66
18.3
549.7
32
0.1439
250
250
19/4.09
20.45
687.1
40
0.1151
315
315
37/3.29
23.03
867.9
52
0.0916
400
400
37/3.71
25.97
1102
64
0.0721
450
450
37/3.94
27.58
1239.8
72
0.0641
500
500
37/4.15
29.05
1377.6
80
0.0577
560
560
37/4.39
30.73
1542.9
89.6
0.0515
630
630
61/3.63
32.67
1738.3
100.8
0.0458
710
710
61/3.85
34.65
1959.1
113.6
0.0407
800
800
61/4.09
36.81
2207.4
128
0.0361
900
900
61/4.33
38.97
2483.3
144
0.0321
1000
1000
61/4.57
41.13
2759.2
160
0.0289
1120
1120
91/3.96
43.56
3093.5
179.2
0.0258
1250
1250
91/4.18
45.98
3452.6
200
0.0231
1400
1400
91/4.43
48.73
3866.9
224
0.0207
1500
1500
91/4.58
50.38
4143.1
240
0.0193
ASTM B 399/B 399M
Code Name
Total Area
1350 Grade Equivalent
No./Dia.
of Wire
Approx. Overall Diameter
Approx. Weight
Calculated Breaking
Load
Max.DC Resista-nce at 20° C
AWG or MCM
mm2
(Approx.)
AWG or MCM
No. / mm
mm
kg/km
kN
Ohm/km
Akron
30.6
15.5
6
7/1.68
5.04
43
4.9
2.1588
Alton
48.7
24.7
4
7/2.12
6.36
68
7.8
1.3557
Ames
77.5
39.2
2
7/2.67
8.01
108
12.4
0.8547
Azusa
123.3
62.4
1
7/3.37
10.11
171
18.9
0.5365
Anaheim
155.4
78.6
2/0
7/3.78
11.34
216
23.8
0.4264
Amherst
195.7
99.3
3/0
7/4.25
12.75
272
30
0.3373
Alliance
246.9
125.1
4/0
7/4.77
14.31
343
37.8
0.2678
Butte
312.8
158.6
266.8
19/3.26
16.3
435
46.5
0.2112
Canton
394.5
199.9
336.4
19/3.66
18.3
548
58.6
0.1676
Cairo
465.4
236.4
397.5
19/3.98
19.9
649
69.3
0.1417
Darien
559.5
283.6
477
19/4.36
21.8
778
83.1
0.1181
Elgin
652.6
331
556.5
19/4.71
23.55
908
97
0.1012
Flint
740.8
374.5
636
19/3.59
25.13
1028
107.4
0.0894
Greeley
927.2
469.6
795
19/4.02
28.14
1289
134.6
0.0713
AAAC conductor-ASTM B 399B 399M
Nominal Area
Stranding
Overall Diameter
Weight
Rated Strength
Electrical Resistance
Current Rating*
AWG&MCM
mm^2
No./mm
mm
kg/km
KN
Ω/Km
A
6
13.2
7/1.55
4.65
36.2
4.18
2.5361
69
4
21.1
7/1.96
5.88
57.9
6.69
1.586
93
2
33.5
7/2.47
7.41
92
10.6
0.9987
123
0
53.5
7/3.12
9.36
146.8
17
0.62592
165
2/0
67.3
7/3.50
10.5
184.8
20.4
0.49738
190
3/0
84.9
7/3.93
11.79
233
25.7
0.3945
219
4/0
107
7/4.42
13.26
294.7
32.5
0.31188
253
250
126
19/2.91
14.55
346.7
38.8
0.26509
280
300
152
19/3.19
15.95
416.7
46.6
0.22059
313
350
178
19/3.45
17.25
487.3
52
0.1886
345
400
203
19/3.69
18.45
557.5
59.5
0.16486
375
450
228
19/3.91
19.55
626
66.8
0.14683
402
500
253
19/4.12
20.6
695
74.2
0.13224
429
550
279
37/3.10
21.7
766.2
83.9
0.11995
455
600
303
37/3.23
22.61
831.9
91
0.11049
478
650
330
37/3.37
23.59
905.5
94.9
0.1015
504
700
354
37/3.49
24.43
971.2
101
0.09464
525
750
381
37/3.62
25.34
1045
109
0.08796
549
800
404
37/3.73
26.11
1109
116
0.08285
569
900
456
37/3.96
27.72
1250
131
0.07351
612
1000
508
37/4.18
29.26
1393
146
0.06597
653
1250
631
61/3.63
32.67
1732
179
0.05306
743
1500
759
61/3.98
35.82
2082
215
0.04414
827
1750
886
61/4.30
38.7
2431
251
0.03781
904
Company Profile
Exhibition
Certificate
Transport
FAQ
Q:I didn't find the Aaac Conductor All Aluminum Alloy Concentric Cable which I need in this page? A:If you didn't find the species of cables you need, please contact us directly, we will reply you quickly.
Q:What's your minimum order quantity? A:It is not so sure, you can confirm it with us. Normally, it will be 1000 meters.
Q:What's your delivery time? A:It depends on whether we just has the stock for your type.Normally,it takes about 7-15days to achieve production.
Q:How can I get a sample from your company? Is the sample free? A:If you need the sample to check the quality, please contact us, we will send you the free sample, but the freight charge should be paid.
Q:How to ensure quality ? A:For any quality problems, we will arrange the technical personnel to solve or return the goods as soon as possible, and bear the corresponding customer losses.
Q:What if the cable which we need have some differences on specifications from yours? A: Any difference, we can design and produce according to your requests, which include cable, color, material, processing requirement etc.

You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now