aluminium 11kv aerial bunched electric cable three phase
Covered line Wire is used primarily for 600v overhead secondary distribution lines. It is not an electrically insulated conductor and is treated as bare conductor when installed.
*CONSTRUCTION:
The conductors are 1350-H19 Aluminum Wire ,6201-T81 Aluminum Alloy or ACSR conductors, concentrically stranded and covered for weather proofing with polyethylene, high density polyethylene(HDPE) or cross-linked polyethylene(XLPE).
Duplex Service Drop---Aluminum Conductor
*CONSTRUCTION:
Conductors are concentrically stranded, compressed 1350-H19 aluminum.
Neutral messengers are concentrically stranded 6201, AAC, or ACSR.
Nominal cross section | Neutral core | Phase core | weight (kg/km) | Allowable ampacity (A) | ||||||||||
AAC | LBS | AAC | Insulation thickness(mm) | XLPE | PE | |||||||||
NO | diameter (mm) | NO | diameter(mm) | |||||||||||
1*6AWG+1*6AWG | 7 | 1.56 | 563 | 1 | 4.11 | 1.14 | 92 | 85 | 70 | |||||
1*6AWG+1*6AWG | 7 | 1.56 | 563 | 7 | 1.56 | 1.14 | 94 | 85 | 70 | |||||
1*4AWG+1*4AWG | 7 | 1.96 | 881 | 1 | 5.19 | 1.14 | 139 | 115 | 90 | |||||
1*4AWG+1*4AWG | 7 | 1.96 | 881 | 7 | 1.96 | 1.14 | 141 | 115 | 90 | |||||
1*2AWG+1*2AWG | 7 | 2.47 | 1350 | 7 | 2.47 | 1.14 | 216 | 150 | 120 | |||||
1*1/0AWG+1*1/0AWG | 7 | 3.12 | 1990 | 19 | 1.89 | 1.52 | 347 | 205 | 160 |
Triplex Service Drop---Aluminum Conductor
Used to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made.
*CONSTRUCTION:
Conductors are concentrically stranded, compressed 1350-H19 aluminum.
AWG or kcmil | Bare Neutral Messenger | Phase Conductor | Weight kg/km | Allowable Ampacities(A) | ||||||||||
AAC | Rated Strength lbs. | AAC | Insul. Thick. mm | XLPE | PE | |||||||||
NO. | Dia.mm | NO. | Dia.mm | |||||||||||
2*6AWG+1*6AWG | 7 | 1.56 | 563 | 1 | 4.11 | 1.14 | 146 | 85 | 70 | |||||
2*6AWG+1*6AWG | 7 | 1.56 | 563 | 7 | 1.56 | 1.14 | 150 | 85 | 70 | |||||
2*4AWG+1*4AWG | 7 | 1.96 | 881 | 1 | 5.19 | 1.14 | 219 | 115 | 90 | |||||
2*4AWG+1*4AWG | 7 | 1.96 | 881 | 7 | 1.96 | 1.14 | 224 | 115 | 90 | |||||
2*2AWG+1*2AWG | 7 | 2.47 | 1350 | 7 | 2.47 | 1.14 | 338 | 150 | 120 | |||||
2*1/0AWG+1*1/0AWG | 7 | 3.12 | 1990 | 7 | 3.12 | 1.52 | 544 | 205 | 160 | |||||
2*1/0AWG+1*1/0AWG | 7 | 3.12 | 1990 | 19 | 1.89 | 1.52 | 545 | 205 | 160 | |||||
2*2/0AWG+l*2/0AWG | 7 | 3.5 | 2510 | 7 | 3.5 | 1.52 | 671 | 235 | 185 | |||||
2*3/0AWG+l*3/0AWG | 19 | 2.39 | 3310 | 19 | 2.39 | 1.52 | 830 | 275 | 215 | |||||
2*4/0AWG+l*4/0AWG | 19 | 3.25 | 4020 | 19 | 3.25 | 1.52 | 1476 | 315 | 245 | |||||
2*336.4+1*336.4 | 19 | 3.38 | 6146 | 19 | 3.38 | 2.03 | 1649 | 420 | 325 |
*APPLICATIONS:
Used to supply 3-phase power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made.
*CONSTRUCTION:
Conductors are concentrically stranded, compressed 1350-H19 aluminum.
AWG or kcmil | Bare Neutral Messenger | Phase Conductor | Weight kg/km | Allowable Ampacities(A) | ||||||||||
ACSR | Rated Strength lbs. | AAC | Insul. Thick. mm | XLPE | PE | |||||||||
No. | Dia. mm | No. | Dia. mm | |||||||||||
3*6AWG+1*6AWG | 1,6 | 1.68 | 1190 | 1 | 4.11 | 1.14 | 221 | 75 | 60 | |||||
3*6AWG+1*6AWG | 1,6 | 1.68 | 1190 | 7 | 1.56 | 1.14 | 227 | 75 | 60 | |||||
3*4AWG+1*4AWG | 1,6 | 2.12 | 1860 | 1 | 5.19 | 1.14 | 331 | 100 | 80 | |||||
3*4AWG+1*4AWG | 1,6 | 2.12 | 1860 | 7 | 1.96 | 1.14 | 338 | 100 | 80 | |||||
3*2AWG+1*2AWG | 1,6 | 2.67 | 2850 | 7 | 2.47 | 1.14 | 511 | 135 | 105 | |||||
3*1/0AWG+1*1/0AWG | 1,6 | 3.37 | 4380 | 19 | 1.89 | 1.52 | 824 | 180 | 140 | |||||
3*2/0AWG+l*2/0AWG | 1,6 | 3.78 | 5310 | 19 | 2.13 | 1.52 | 1015 | 205 | 160 | |||||
3*3/0AWG+l*3/0AWG | 1,6 | 4.25 | 6620 | 19 | 2.39 | 1.52 | 1254 | 235 | 185 | |||||
3*4/0AWG+l*4/0AWG | 1,6 | 4.77 | 8350 | 19 | 2.68 | 1.52 | 1554 | 275 | 210 | |||||
3*336.4+1*336.4 | 1,18 | 3.47 | 8680 | 19 | 3.38 | 2.03 | 2321 | 370 | 280 | |||||
3*336.4+l*4/0AWG | 1,6 | 4.77 | 8350 | 19 | 3.38 | 2.03 | 2221 | 370 | 280 |
ASTM B-230 - Aluminum Wire 1350-H19 for Electrical Purposes
ASTM B-231 - Concentric-Lay-Stranded Aluminum Conductors
ASTM B-232 - Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR)
ASTM B-399- Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors
ICEA S-61-402-: Thermoplastic-insulated Wire And Cable For The Transmission And Distribution Of Electrical Energy
ICEA S-66-524-XLPE Insulated Wire and Cable For the Transmission and Distribution of Electrical Energy
Product name: | Iec Compact ABC conductor Cable | ||||||
Voltage:
| U0/U=0.6/1KV | ||||||
Technical data: |
1. Maximum operating temperature 90 degrees. 2. Maximum short circuit temperature 250 degrees | ||||||
Application field: | 1. Areas where underground networks are expensive. 2. Electrification of rural areas | ||||||
Road conductor type: | 1 AAC: all aluminum bare wire. Bare conductor of ASC: aluminum strand. 2 AAAC: all aluminum alloy bare conductor. Bare conductor of AASC: aluminum alloy stranded wire. 3 ACSR: steel core aluminum wire |
People's Cable Group Co., Ltd.
Our mainly products as follow:
2.PVC insulated power cable and xlpe insulated power cable with or without armor upto 35kv.
3.Rubber cable like welding cable, mining cable, control cable and so on.
4.Aerial bundled cable(ABC cable) up to 10kv, like Duplex ABC cable, Triplex ABC cable, Quadruplex ABC cable and so on.
5.Bare conductor like AAC, AAAC, ACSR, AACSR, ACAR, ACSR/AW, aluminum clad steel wire, galvanized steel wire and so on.
Q1:When can I get the price?
We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please call us or tell us in your email so that we
will regard your inquiry priority.
Q2.How can I get a sample to check your quality?
After price confirmation, you can require for samples to check our quality. Sample is free, but the freight charge should be paid.
Q3.How long can I expect to get the sample?
After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7 days.
The samples will be sent to you via express and arrive in 3~5 days.
Q4.What about the lead time for mass production?
Honestly, it depends on the order quantity and the season you place the order.The best record we keep is delivering 10 kilometers cable within a week. Generally speaking, we suggest that you start inquiry two months before the date you would like to get the products at your country.
You May Like
- Electric Three Phase 10mm Aluminium Wire XLPE Cable Prices
- 25mm2 50mm2 240mm2 Overhead Aluminum Aerial Bundle Power Line Conductor Cable
- Aluminum 11kv 3 core Lepas Triplex Service Drop ABC cable from China
- 3x25mm2 XLPE Insulated 11kv ABC Aerial Bundle Cable
- ASTM Standard Overhead Sizes Cable abc
- Aluminum Overhead ABC Aerial Bundle Cable
- Prices 630mm 185mm 3 Core Aluminium XLPE ABC Cable
- 22kv Overhead Xlpe Power Aerial Bundle Electric Cable Size
- power kabel acsr 9515mm2 overhead messenger cable
- 15mm aluminum xlpe overhead abc cable
Popular Searches
Find Similar Products By Category
You May Like
- 33kv 11kv 500mm2 Aerial Bundled Electric Cable Aluminum Overhead ABC Cable
- 3x25mm2 Aluminum Conductor Overhead ABC Cable
- prices 6 awg duplex phase wire acsr conductor 4 core 95mm abc cable
- ABC Cable Triplex Wire Sizes Aluminium Cable 35mm2 3 Phase 5 Core Cable
- 3x35546 16mm2 185mm aluminum conductor abc aluminium cable 4 mm
- Manufacturer 33 KV ACSR /AW-OC XLPE Insulated Electric Cable
- 110kv XLPE Insulated Overhead ABC Power Cable
- XLPE Insulated Overhead 33kv ABC Aerial Bundle Power Cable
- 300mm2 XLPE Insulated Electrical Overhead ABC Power Cable
- XLPE Insulated Cable Price List 11kv Overhead ABC Cable Sizes
- 11kv XLPE Aerial Bunched ABC Cable Price Street light Overhead Cable
- 70mm Waterproof Electrical Wire High Voltage Electric PVC Cable For House
- Electric Wire 5.5 mm 1.0mm Multicore Flexible Electrical Cable 4x35mm
- Supplies House Electric Cable 1.25mm Electrical Soft 5 Wires
- 1.25mm 1.60mm 2.0mm 2.5mm 16mm 25mm2 PVC Electrical Cables Wire For Household