Product Details

OEM sizes electrical cable wire 10mm, 2.5mm electrical wire cable

Brand Name ZLRC
Place of Origin Beijing, China
Model Number ZLRC-6-35kv
Type Medium Voltage
Application Construction
Insulation Material XLPE
Jacket PVC
Conductor Material Copper

Product Features

Product Description

OEM sizes electrical cable wire 10mm, 2.5mm electrical wire cable

Product Description Of 50mm2 Rubber 2.5mm electric cable wire 10mm

This product is suitable for AC rated voltage 450/750 V and below voltage. It is often used as copper core rubber insulated flexible cable in home appliances, power tools, and all kinds of movable electric equipment. The long-term allowable working temperature of cable shall not exceed 60 ℃.

1. 50mm2 Rubber 2.5mm electric cable wire 10mm Execution standard: GB/T50 13-2008 JB/T8735-2011

2.50mm2 Rubber 2.5mm electric cable wire 10mm Models and name:

YZ, YZW types are medium-sized rubber flexible cables. They are used for all kinds of movable electrical equipment and tools.

YC, YCW types are heavy duty rubber soft cables. They are used for various kinds of movable electrical equipment, and can bear heavier machine force.

* Cables are derived from 'W' type cable, possess ability of climate and oil resistance, and is suitable for outdoor use or oil pollution applications.

3. Application:

These cables are designed for the connection of mobile equipment and machines under very high mechanical loads in dry and damp areas, outdoors and in explosion hazard areas, particularly in mining and industry, quarries and building sites.

4. 50mm2 Rubber 2.5mm electric cable wire 10mmTechnical Parameters:

1) 300/500v YZ, YZW type medium sized rubber flexible cable.


Characteristics

Normal area
(mm2)
Structure
(mm)
Insulated
thickness
(mm)
Overall dia.
(mm)
Normal area
(mm2)
Structure
(mm)
Insulated
thickness
(mm)
Overall (mm2)
dia. (mm)
2x0.50
28/0.15
0.50
5.20
4x1.00
32/0.20
0.60
8.00
2x0.75
24/0.20
0.50
6.40
4x1.50
30/0.25
0.70
9.20
2x1.00
32/0.20
0.60
6.60
4x2.50
49/0.25
0.80
10.90
2x1.50
30/0.25
0.70
7.60
4x4.00
56/0.30
0.80
12.80
2x2.50
49/0.25
0.80
9.40
4x6.00
84/0.30
0.80
15.40
3x0.50
28/0.15
0.50
5.50
4x10.00
126/0.32
1.00
17.60
3x0.75
24/0.20
0.50
6.80
4x16.00
126/0.40
1.00
21.10
3x1.00
32/0.20
0.60
7.20
5x1.50
48/0.20
0.70
10.70
3x1.50
30/0.25
0.70
8.50
5x2.50
49/0.25
0.80
12.80
3x2.50
49/0.25
0.80
10.00
5x4.00
56/0.30
0.80
14.50
3x4.00
56/0.30
0.80
11.70
5x6.00
84/0.30
0.80
16.40
3x6.00
84/0.30
0.80
13.00
5x10.00
126/0.32
1.00
20.10
3x10.0
126/0.32
1.00
16.10
5x16.00
126/0.40
1.00
24.40
3x16.0
126/0.40
1.00
19.40
Type
Designation
Applications
VV
Copper conductor,PVC insulated, PVC sheathed power cable
For laying indoors,in tunnel or cable  trench, unable to bear external  mechanical forces. Single core cable is not  allowed to laid in magnetic duct.
VLV
Aluminum conductor,PVC insulated, PVC sheathed power cable
VY
Copper conductor, PVC insulated, PE sheathed power cable
VLY
Aluminum conductor, PVC insulated, PE sheathed power cable
VV22
Copper conductor,PVC insulated, steel tape armoured, PVC sheathed power cable


For laying indoors,in tunnel in cable trench, or direct in ground,able to bear external  mechanical forces. Single core cable is not  allowed to laid in magnetic duct.
VLV22
Aluminum conductor,PVC insulated, steel tape armoured,PVC sheathed power cable
VV23
Copper conductor,PVC insulated, steel tape armoured,PE sheathed power cable
VLV23
Aluminum conductor,PVC insulated, steel tape armoured,PE sheathed power cable
VV32
Copper conductor,PVC insulated, steel wire armoured,PVC sheathed power cable



For laying indoors,in tunnel cable trench, well or direct in ground, able to bear external mechanical forces and certain pulling force.
VLV32
Aluminum conductor,PVC insulated, steel wire armoured,PVC sheathed power cable
VV33
Copper conductor,PVC insulated, steel wire armoured,PE sheathed power cable
VLV33
Aluminum conductor,PVC insulated, steel wire armoured,PE sheathed power cable

Application:

    This product is applicable to power lines with rated voltage of 1kV and below and 3KV and below.Suitable for laying in hotels, stations, chemical industry, oil platforms, mines, power stations, subways, tunnels, high-rise buildings, etc.

1. Long term working temperature for the cable with PVC insulated is 70℃;
    Long term working temperature for the cable with XLPE insulated is 90℃
2. Short circuit temperature
     For PVC insulated cable ,the highest conductor temperature is not more than160℃. (lasting time not over 5 seconds).
     For XLPE insulated cable ,the highest conductor temperature is not more than250℃. (Lasting time is not over 5 seconds).
3. Laying temperature not less than 0℃ and the drop height is out of consideration.
4. The cable with chemical stability, anti- acid, anti-alkali, anti-oil, anti-organic solvent, not easy to be burning.
5. Easy for installation, easy bending and light.

Detailed Images
Packing & Delivery
Certifications
Our Service
FAQ

1. Q: Are you trading company or manufacturer ?

     A: We are factory.

2. Q: Do you provide samples ? is it free or extra ?
    A: Yes, we could offer the sample for free charge but do not pay the cost of freight.

3. Q: How long is your delivery time?
     A: Generally it is 10 days if the goods are in stock. or it is 30 days if the goods are not in stock, it is according to quantity.

4. Q: What is the regular shipping port?                                  

    A: Tianjin Port.

5. Q:What is your terms of payment ?                                      

     A: Payment<=5000USD, 100% in advance. Payment>=5000USD, 50% T/T in advance, the balance should be paid before shippment.

You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now