Small Business Fire Security 2 Zone Alarm Fire Alarm Control Panel
Negotiable /Piece
Min.Order:1 Piece
Vedard Foreign Trade (Quanzhou) Co.,Ltd.
4-16 Zones Alarm Conventional Fire Alarm Control Panel Security Controller
Fire Alarm And Fire Fighting Gas Extinguish Security Control Fire Controller
64 Point Addressable Fire Alarm Control Panel Wireless Fire Alarm System
2 Wire 255 Point 1 loop Addressable Fire Alarm Control Panel
Gas H2S Alarm Explosion Proof Toxic Gas Detector Environment Security
Perimeter Security Infrared Beam Intruder Detector Wireless Alarm Solar Power Photoelectric Beam
Small business fire security alarm system.
CP-1002 Mini size designed conventional fire alarm 2 zone panel is used for family hotel fire security, restaurant fire security, store or shop fire security alarm.
Automatic fire alarm system is a device that automatically detects, displays and sends out fire alarm when fire occurs to the protected object. It is widely used in modern factories, material warehouses, high-rise buildings, computing centers and other buildings, to ensure the safety of people's lives and property plays a huge role.
Automatic fire alarm system is composed of trigger device, fire alarm device, fire alarm device, power supply and linkage device with other auxiliary control function.
Conventional 2-zone multi-wire fire alarm controller, equipped with any 2-wire smoke, temperature, alarm button and alarm bell, sound and light. At the same time can be equipped with security alarm equipment.
More fire alarm systems with free technical support at conventional fire alarm
Description:
1. The Mini fire alarm control master panel and slave panel each has 2 zones and each zone can equip Max.30 detectors and call points.
2. It should be installed, commissioned and maintained by suitably qualified service personnel with reference to IEE regulations and any statutory requirements.
3. The 2 zones alarm panel has 1 alarm sound output zones (bell zones), which can equip max.16 sounders for total max. 1A/24V power supplied.
4. The panel (master or slaver) has 24V auxiliary power output supply 2A/24V with fire 1, fire 2 relay output and fault relay output.
5. It is external DC24V power supplied with backup battery.
6. It supports detector head removal and easy for repair or maintenance.
7. It has Test/reset, silence alarm and Evacuate button for easy panel operation.
8. It has indicators of zone1 alarm /fault, zone2 alarm /fault, Sound alarm, and sound fault LED. That clearly showed detectors and sound circuit staturs.
9. There is one master fire alarm control panel and it can work with Max.31 same slaver panel.
10. The master fire control panel will communicate slaver panel one by one and fault will be showed if no response is received.
11. Alarm and fault events of panel No. and zone No. will be showed one by one on Master fire control panel.
Specification:
1. System Power Supply: It is external 22-26VDC power supplied. (With upgrade version with internal power supply available)
2. Standby current:<50mA
3. Alarm current(not include the others):<150mA
4. Detector Voltage (VDC): 24V
5. Number of sensor zones: 2 zones
6. Max. number of detectors per zone: 30
7. Alarm Voltage: 24V
8. Number of alarm zone: 1
9. Max. Alarm current per zone: 300mA
10. Max. number of sounders per zone: 16
11. Max. sounder supply current in fire: 1A/24V
12. Fire fault relay contacts loads: 2A/24V
13. Panel weight without battery: 520g
14: Diameter: 108mm*143mm*40mm
upc code: 782123753055
ean code: 0782123753055