tiandi shouhe online methylamine alarm td-95h-ch3nh2-a
Negotiable /Unit
Min.Order:0 Unit
Beijing Qizhi Haotian Technology Co., Ltd.
Online Methylamine AlarmTD-95H-CH3NH2-AFeatures
Uses German *** methylamine sensor
Standard with three-wire 4 - 20mA analog signal output; Relay output, RS485 output (optional)
**** Infrared remote control function, enabling non-contact operation and maintenance of the instrument
Compatible with various control alarms, PLC, DCS and other control systems, enabling remote monitoring,
Explosion-proof ****, fast, ***, stable; Explosion-proof grade is Ex dⅡCT6
Full software automatic calibration function, the machine is equipped with three buttons to achieve single-person single-point on-site maintenance
Online Methylamine AlarmTD-95H-CH3NH2-ACharacteristics
Monitors and alarms the concentration of methylamine in the environment or pipeline
Full software automatic calibration function, zero calibration function, making gas monitoring ***, ***
With temperature compensation, it can realize the compensation of gas concentration in different temperature environments
Two-level sound and light alarm, and the alarm point can be set by itself
Infrared remote control can remotely and non-open-cover to achieve functions such as setting the alarm point, zero calibration, and modifying the address
Can output one or two switching signals, which can drive external devices such as exhaust fans or solenoid valves
Operating voltage: 12 - 36V DC power supply
Housing material: Die-cast aluminum + Stainless steel (alarm light)
Detected Gas | Methylamine (CH3NH2) | ||
Detection Principle | Electrochemical principle | ||
Installation Method | Wall-mounted, Pipeline-mounted, Flow-through (related to the monitoring environment) | ||
Measurement Range | 0 - 99ppm, 0 - 500ppm, 0 - 990ppm (Optional range, custom range not listed) | ||
Resolution | 0.01ppm, 0.1ppm (Resolution is related to the selected range) | ||
Precision | 2%FS | ||
Output Signal | 4 - 20MA, 0 - 5V, RS485, RS232, Relay, Wireless Digital (optional) | ||
Response Time | ≤10S | Recovery Time | ≤10S |
Repeatability | ≤±1% | Linearity Error | ≤±1% |
Zero Shift | ≤±1% (F.S/Year) | Display **** | High-brightness digital tube display |
Connection Mode | G1/2 Male Thread Explosion-proof Hose | Gas Unit | PPM |
Operating Temperature | -40℃ to 70℃ | Operating Humidity | 0 - 95%RH |
Explosion-proof Grade | Ex dⅡCT6 | Degree of Protection | IP65 |
Alarm Mode | Sound and light dual alarm | Operating Time | 24-hour operation |
Dimensions | 180×150×90mm | Weight | ≤1.6kg |
Online Methanamine AlarmTD-95H-CH3NH2-A***:
The product is guaranteed for free repair for one year from the delivery date for non-human damage, and lifetime maintenance service.