Application
Measuring the volume of cold (hot) water passing through the pipeline.
Note
This water can be used for a remote reading transmission system as equipped with a built-in sensor.
Feature
a)Removable element structure,easy installation and maintenance,registerfor universal use within this range detachable without removing the meter from the pipeline;
b)Dry-dial,magnetic driven,with sensitive action,small pressure loss;
c)Vacuum sealed register ensures the dial face keep free from fog and reading clearly in a long time;
d)High quality materials for steady and reliable characteristic;
e)echnical data conform to ISO 4064 Class B,and ISO4064-1:2005.
Working condition
Water temperature:0.1℃~50℃(cold water meter) 0.1℃~90℃(hot water meter)
Water pressure:≤1.0MPa(1.6MPa)
Maximum permissible errors
From Q1 to Q2:±5%
From Q2 to Q4:±2%(±3% for water meter)
MAIN TECHNICAL SPECIFICATIONS
Type | Size(mm) | Q3/Q1 | Overload Flow | Permanent Flow | Transitional Flow | Min. Flow | Min. Reading | Max. Reading |
m3/h | M3 | |||||||
LXLC-50 | 50 | 50 | 31.25 | 25 | 2 | 0.5 | 0.0005 | 999,999 |
LXLC-65 | 65 | 50 | 40 | 3.2 | 0.8 | 0.0005 | 999,999 | |
LXLC-80 | 80 | 78.75 | 63 | 5.04 | 1.26 | 0.002 | 999,999 | |
LXLC-100 | 100 | 125 | 100 | 8 | 2 | 0.002 | 999,999 | |
LXLC-125 | 125 | 200 | 160 | 12.8 | 3.2 | 0.002 | 999,999 | |
LXLC-150 | 150 | 312.5 | 250 | 20 | 5 | 0.002 | 999,999 | |
LXLC-200 | 200 | 500 | 400 | 32 | 8 | 0.002 | 999,999 | |
LXLC-250 | 250 | 787..5 | 630 | 50.4 | 12.6 | 0.02 | 9,999,999 | |
LXLC-300 | 300 | 1250 | 1000 | 80 | 20 | 0.02 | 9,999,999 |