CIT-01 Charpy and Izod Impact Tester
Application
Impact testing is a crucial method in materials science and engineering, used to assess a material’s ability to withstand sudden loading or impact forces. Among the various impact tests, the Charpy and Izod tests are widely employed to evaluate a material’s toughness and resistance to fracture. Both tests provide insights into the extent of plastic deformation the material can endure before facing failure.
While they share similarities, they also have key differences in their specimen configurations and testing procedures. Below are the main differences between the Izod and Charpy impact tests.
Differences Charpy Impact Testing Izod Impact Testing
Materials Tested Metal, plastics, and composites
Types of Notches U-notch and V-notch V-notch only
Specimen Position Horizontally, notch facing away from pendulum Vertically, notch facing toward the pendulum
Striking Point Middle of the sample Upper tip of the sample
Specimen Dimensions 55*10*10mm 64*12.7*3.2mm (plastic) or 127*11.43mm round bar (metal)
CIT-01 Charpy and Izod Impact Tester is a touch screen type impact testing machine mainly used to measure the impact toughness of non-metallic materials such as hard plastics, reinforced nylon, fiberglass, ceramics, cast stone, electrical insulation materials, etc. It is an ideal choice for the chemical industry, scientific research institutions, and colleges Ideal testing equipment for colleges, quality inspection and other sectors.
Technical Features
● Both Charpy and Izod tests combined.
● PLC control and touch screen operated.
● Chinese and English language switch.
● 5 sample data storage and calculation of the average impact energy.
● Simple operation and stable performance.
Standards
Charpy: ISO 179-1,GB/T 1043, GB/T 21189, JB/T 8762
Izod: ISO 180,GB/T 1843, GB/T 21189, JB/T 8761
Main Parameters Charpy Parameter Izod Parameter
Impact Velocity 3.8 m/s 3.5 m/s
Impact Energy "7.5, 15, 25, 50J
(choose one)" "1, 2.75, 5.5, 11J, 22J
(choose one) "
Impact Angle 160° 160°
Radius Of Striking Edge R=2±0.5mm R=0.8±0.2mm
Radius Of Curvature Of Anvils R=1±0.1mm R=1±0.1mm
Span Between Supports "40 mm, 62 mm
70 mm, 95mm" vice jaw
Angle Of Striker Tip 30°±1° 75°±1°
Energy Absorbed 0.50% 0.50%
Dimension 550*350*850mm