TC100N Fixed Point Gas Detector
Negotiable /Piece
Min.Order:10 Pieces
Henan Greeenland Tech Industrial Co., Ltd
Fixed Gas Detector Description
TC100N is a fixed gas detector installed in a place where potential gas hazard exists to measure oxygen, toxic gas and combustible gas. With ATEX approval, it is suitable for explosive environment use. it communicates with the control panel through 4-20mA analog output or RS485 digital signal.
The fixed gas detector is uesd forSteelworks, Petrochemical plants, Shipyards, Water treatment plants, Mines. Power plants, Food industry etc.
Fixed Gas Detector Key Features
ATEX approved
4-20mA analog or RS485 digital output
2 relay output for 4-20mA type
Sensor module design, easy for replacement
Different sampling methods
Natural diffusion is that the gas in the detected area flows slowly into the instrument for detection with the free flow of air, and needs to be placed on site. This method is affected by the detection environment, such as ambient temperature, wind speed, etc., and is not suitable for gas sources with low pressure. The advantage is low cost.
The pump suction type is that the instrument is equipped with a gas sampling pump. Its working method is that the power supply drives the gas sampling pump to extract and sample the gas in the test area, and then the sample gas is sent to the instrument for detection.The characteristics are fast detection speed, long-distance measurement of dangerous areas, and safety of maintenance personnel. It is suitable for occasions where the gas detector cannot be placed on site and has special requirements for reaction speed, pressure difference, etc.
Fixed Gas Detector Specifications
Measuring gas | O2 | CO | H2S | Combustible |
Measuring range | 0-25%vol | 0-500ppm | 0-100ppm | 0-100%LEL |
Resolution | 0.1%vol | 1ppm | 1ppm | 1%LEL |
Sensor type | Electrochemical | Electrochemical | Electrochemical | Catalytic |
Sensor life | 1 year | 2 years | 2 years | 2 years |
Sampling method | Natural diffusion | |||
Response time | Toxic gas and O2: T90≤60s; Combustible: T90≤30s | |||
Working temperature | -20℃~50℃ for toxic gas -40℃~70℃ for combustible gas | |||
Signal output | 4-20mA/RS485 | |||
Alarm output signal | 2 programmable relays for 4~20mA type | |||
Conduit connection | G1/2 | |||
Cable required | ≥1.5mm2×3 core cable(4-20mA type) ≥1.5mm2×4 core cable(RS 485 type) | |||
Transmission distance | ≤1000m | |||
Mounting type | Wall mounted | |||
Working temperature | oxic gas:-20℃~50'C Combustible gas: -40℃~70℃ | |||
Working humidity | ≤95%RH(no condensation) | |||
Operation voltage | DC24V±25% | |||
Consumption | <2W | |||
Ingress Protection | IP65 | |||
Housing material | Chamber: Aluminum alloy Sensor cover: Stainless steel | |||
Dimension and weight | 196mm×186mm×68.5mm, about 1.2kg | |||
Approval | Ex Ⅱ 2G Ex db llC T6 Gb | |||
Cable / distance | 4-20mA type: 1.5 MM2, 3 wire, shielded,1000m (maximum) RS485 type: 1.5 MM2, 4 wire, shielded, 1000m (maximum) |