DESCRIPTION

The RPS6U rack power supplies are designed for use in the series of machinery protection systems and condition and performance monitoring systems.

A RPS6U rack power supply is installed in the front of a ABE04x system rack (19″ system racks with a standard height of 6U) and connects via two high-current connectors to the bus of the rack’s backplane. The RPS6U power supply provides +5 VDC and ±12 VDC to the rack itself and all installed modules (cards) in the rack via the rack’s backplane.

Either one or two RPS6U rack power supplies can be installed in a ABE04x system rack. A rack with one RPS6U power supply (330 W version) supports the power requirements for a full rack of modules (cards) in applications with operating temperatures up to 50°C (122°F).

Alternatively, a rack can have two RPS6U power supplies installed in order to either support rack power supply redundancy or in order to supply power to the modules (cards) non-redundantly over a wider range of environmental conditions.

A ABE04x system rack with two RPS6U power supplies installed can operate redundantly (that is, with rack power supply redundancy) for a full rack of modules (cards). This means that if one RPS6U fails, the other will provide 100% of the rack’s power requirement so that the rack will continue to operate, thereby increasing the availability of the machinery monitoring system.

Note: This is known as a redundant RPS6U rack power supply configuration.
A ABE04x system rack with two RPS6U power supplies installed can also operate non-redundantly (that is, without rack power supply redundancy). Typically, this is only necessary for a full rack of modules (cards) in applications with operating temperatures above 50°C (122°F), where RPS6U output power derating is required.

Note: Even though two RPS6U rack power supplies are installed in the rack, this is not a redundant  RPS6U rack power supply configuration.


Sumset International Trading Co., Limited

Parent company: Xiamen Hongxinhe Trading Co., Ltd. 

Levi (Sales Manager/Technical Consultant)

Mobile (WhatsApp/Wechat): +86 18030030532

Email: sales13@htechplc.com

Website: /

Address: Room 1904, Building B, Diamond Coast, No. 96 Lujiang Road, Siming District, Xiamen, Fujian, China 361001


You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now