Ethernet Remote I/O Module Supports Modbus RTU to MQTT with 1RS485 for PLC Devices
Ethernet Remote I/O Module Supports Modbus RTU to MQTT with 1RS485 for PLC Devices

Ethernet Remote I/O Module Supports Modbus RTU to MQTT with 1RS485 for PLC Devices

USD $151 - $171 /Piece

Min.Order:1 Piece

Supply Ability:
1000 Piece / Pieces per Month
Port:
SHENZHEN
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
Delivery Detail:
15 days

Quick Details View All >

Brand Name:
BLIIOT
Place of Origin:
China
Model Number:
M120E

Shenzhen Beilai Technology Co., Ltd.

Business license
Main Products: Industrial IoT Gateways

Product Details

The M Series Modbus Remote I/O Module is an industrial class, isolated designed, high reliability, high stability and high precision data acquisition module, embedded 32-Bit High Performance Microprocessor MCU, provides a RS485 interface.  It provides multi I/O, supports standard Modbus RTU, can be intergraded into SCADA, OPC server, HMI and other automation systems. It is design for working in the harsh industrial application environment, widely used in a variety of industrial automation, security monitoring system, automatically measurement and control system.

The M Series Modbus Remote I/O module provides different I/O ports for variety applications. Includes optical-isolated digital inputs, compatibles dry contact and wet contact, supports max 10MHz high speed pulse counter, the DIN1 can be used for encode, digital outputs supports 10Hz~300Khz high speed pulse output or relay outputs, the DO1 supports PWM high-speed pulse output, the output duty cycle from 10-90%; DO2 can be used to control the direction of the stepper motor, isolated 12bits analog inputs, supports 0~5V, 0~10V, 4~20mA, 0~20mA analog signal, 12bits analog outputs, supports 0~10VDC signal output, resistance thermal detector inputs compatibles 2/3 wires PT100 and PT1000. All of the I/O ports are high sampling frequency and special filtering strategy to ensure its reliability.

The M Series Modbus Remote I/O module can work at wide working voltage range, the range is 12 ~ 36VDC with anti-reverse protection design. Also, it provides 1channel 12~36VDC power output for external device to save wiring cost.


M Series Modbus Remote I/O Module Table

Model

Descriptions

DC Output

DC Input

Classic Power Consumption

M100

1 RS485, 2 DI, 2 AI, 2 DO(Sink) or Relay

1 DC

12~36VDC

0.84W-1.32W

M110

1 RS485, 4 DI, 4 DO(Sink) or Relay

1 DC

M120

1 RS485, 4 DI, 4 AI, 2AO, 4 DO(Sink) or Relay

1 DC

0.84W-1.32W

M130

1 RS485, 8 DI, 4 DO(Sink) or Relay

1 DC

12~36VDC

0.64W-1.84W

M140

1 RS485, 8 DI, 8 DO(Sink) or Relay

1 DC

M150

1 RS485, 8 DI, 4 AI, 4 DO(Sink) or Relay

1 DC

M160

1 RS485, 8 DI, 8 AI, 8 DO(Sink) or Relay

1 DC

M200

1 RS485, 2AO

1 DC

12~36VDC

0.84W-1.32W

M210

1 RS485, 4 DI

1 DC

0.84W-1.32W

M220

1 RS485, 4 DO(Sink) or Relay

1 DC

M230

1 RS485, 4 AI

1 DC

M240

1 RS485, 4 RTD, 2/3 wire PT100/pt1000

---

0.6W-0.84W

M310

1 RS485, 8 DI

1 DC

12~36VDC

0.64W-1.84W

M320

1 RS485, 8 DO(Sink) or Relay

1 DC

M330

1 RS485, 8 AI

1 DC

M340

1 RS485, 8 RTD, 2/3 wire PT100/pt1000

12~36VDC

0.6W-0.84W

M410

1 RS485, 16 DI

1 DC

0.74W-0.96W

M420

1 RS485, 16 DO(Sink) or Relay

0.6W-0.85W



 Mainly Features

Ø Embedded 32-Bit High Performance Microprocessor MCU, inbuilt watchdog;

Ø Power supply 12~36VDC with over voltage and phase-reversal protection;

Ø Optical isolated digital input(Compatible Dry or Wet type);

Ø DIN1 supports max 10MHz high speed pulse counter, can be used to encode measurement;

Ø Digital output(Sink) or relay output, supports 10Hz~300KHz high speed pulse output;

Ø DO1 supports PWM high-speed pulse output, the output duty cycle from 10-90%;

Ø DO2 can be used to control the direction of the stepper motor;

Ø Isolated analog input, 12-bit resolution, supports 0~20mA,4~20mA,0-5VDC, 0-10VDC;

Ø Analog output, 12-bit resolution, supports 0-10VDC;

Ø RTD input, supports PT100 and PT1000 resistance sensor, compatible 2 or 3 wires;

Ø High sampling frequency and special filtering strategy to ensure reliability;

Ø 1 RS485 Serial port, supports Modbus RTU slave;

Ø Provides 1 channel VDC power source output for external device, saving wiring cost;

Ø LED instructions work status, with reset button to reset, easy on-site installation and commissioning;

Ø Using metal shell, protection class IP30. Metal shell and system security isolation, especially suitable for industrial applications in the field;

Ø Small size, L105 * W88 * H30mm, compatible wall installation and DIN35mm industrial rail installation.

4. Technical Specifications

• Digital Input

Sensor Type

Wet Contact (NPN or PNP), Dry Contact

I/O Mode

DI or Event Counter

Dry Contact

• On: short to GND, logic=1
• Off: open, logic=0

Wet Contact (DI to COM)

• On: 10 to 30 VDC,logic=1
• Off: 0 to 3 VDC,logic=0

Counter Frequency

Only the 1st Channel can be used as pulse counter, Compatibles DI and counter simultaneously. Counter value will save after power off.

High Speed Mode: Max. 10Mhz(Default);

Low Speed Mode: Max. 10KHz (Optional, can open the cover to choose low speed mode.)

Digital sampling frequency

500Hz

Digital filtering strategy

Continues 3 times

Isolation

Optical Isolated,3k VDC or 2k Vrms

• Digital Output

Type

Sink or Relay(DC 5A/30V,5A/250VAC)

I/O Mode

DO or Relay or Pulse Output

Pulse Output Frequency

10Hz~300KHz(Only the 1st Channel is Sink type can be used as high speed pulse output, DO1 supports PWM high-speed pulse output, the output duty cycle from 10-90%; DO2 can be used to control the direction of the stepper motor.)

Over-Voltage Protection

50 VDC

Over-Temperature Shutdown

175°C (typical), 150°C (min.)

Load Current

Max.500 mA per channel

Digital sampling frequency

500Hz

Isolation

If DO is Sink type, then no isolation. If it is Relay, then is electrical isolation.

• Analog Input

Type

Differential input

Resolution

12 bits

I/O Mode

Voltage / Current (backside switch selectable)

Input Range

0~5VDC , 0~10VDC, 0~20 mA, 4~20mA,

Accuracy

±0.1% FSR @ 25°C
±0.3% FSR @ -10 and 60°C
±0.5% FSR @ -40 and 75°C

Sampling frequency

20Hz

Isolation

Electrical isolation

• RTD Input

Sensor Type

PT100 or PT1000

Measurement Range

-120~+420

Resolution

0.1°C or 0.1 ohm

Input Connection

2- or 3-wire

Accuracy

±0.1% FSR @ 25°C
±0.3% FSR @ -40 and 75°C

Sampling frequency

20Hz

Isolation

No

• Analog Output

Type

Differential input

Resolution

12 bits

Output Range

0 to 10 VDC

Drive Current

1A (max.)

Accuracy

±0.1% FSR @ 25°C
±0.3% FSR @ -10 and 60°C
±0.5% FSR @ -40 and 75°C

Isolation

No

• Working Power Requirements

Input Voltage

12~36VDC for no-AO output model,

24`36VDC for AO output model;

Peak Voltage:+40VDC, Power consumption: Less than 1.7W,

If equipped relay output, then each Relay action: 0.15W.

Input Current

139 mA @ 24 VDC

• Power Output

Output Voltage

12~36VDC, equal to the input voltage.

Output Current

139 mA @ 24 VDC

• Serial Port

RS485

MODBUS RTU Slave.

Protection

15KV ESD Protection

Modbus Slave address

1~247

Response Time

10mS

Baud Rate

1200,2400,4800,9600,19200,38400,57600,115200Bps;

• Physical Characteristics

Wiring

I/O cable max. 14 AWG

Dimensions

105 x 88 x 30 mm

Weight

Under 205 g

Mounting

DIN rail or wall

• Environmental Limits

Operating Temperature

Standard Models: -10 to 60°C (14 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)

Storage Temperature

-40 to 85°C (-40 to 185°F)

Ambient Relative Humidity

5 to 95% (non-condensing)

Altitude

Up to 3000 m


Special instructions for ordering

1) If the model provides digital input, the DIN default type: wet contact, optional: dry contact. The input type cannot be changed after manufacturer delivered. The DIN1 default is high-speed count mode; it can be changed to low-speed count mode by open the shell and change the internal jumper. If require dry contact input, please note when ordering, if DIN1 require high-speed pulse count mode then must be wet contact.

2) If the model provides digital output, the DO default type: SINK, optional: Relay. The output type cannot be changed after manufacturer delivered. The DO1 supports PWM high-speed pulse output, the output duty cycle from 10-90%; DO2 can be used to control the direction of the stepper motor. If require relay output, please note when ordering, if DO1, DO2 used for high-speed pulse output then must be Sink.

3) The model number: M240, M340 support thermal resistance temperature transmitter default type: PT100, optional: PT1000, if you need PT1000 type of thermal resistance, please note when ordering.

4) The valid number of I / O ports corresponding to the model number is described in the Model List, the not included I/O port in the model is invalid, although in the hardware reserved them.


Contact Supplier

Ms. Echo Wu Chat Now

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Telecommunications > Communication Equipment > Wireless Networking Equipment
Categories
Hi~