SPRAY-319 particle size distributions & concentration ratio analysis analyzer
USD $1000 - $20000 /Set
Min.Order:1 Set
Gold APP Instruments Corporation Limited
SPRAY-319 Industrial laser particle size analyzer is a specially designed and developed bench-top laser particle size analyzer for spray droplet size testing. This instrument adopts laser diffraction & Fraunhofer diffraction principles, with parallel light path design, equips high-performance and high-power laser which working lifetime>25000 hours, guarantee the requirements of spray droplet test easily. The testing range can be adjusted according to the customers requirement.
SPRAY-319 can be applied to fire control, forest, pesticide spray test, medicine nebulizer droplet test, aircraft engine, spray prilling, nozzle research and aerosol etc., it is especially suitable for laboratories of enterprises, universities, and research institutes.
SPRAY-319 particle size distributions & concentration ratio analysis analyzer Advantages
1. Exclusive Patent Technology
It adopts representative Parallel optical testing technology and Spectrum amplification technique, can realize the wide range expansion in limited space. Besides, it adds several auxiliary integration photoelectric detectors, which can effectively collect scattering light from every angle in the testing range, realizing the testing accuracy and reliability in the whole range.
2. Unique Airflow Protection Device
It has airflow protection device, which can effectively protect the lens and avoid droplet pollution to lens in testing process.
3. Split-type Structure Design
Split-type structure and adjustable testing area can meet the needs of the spray test in any conditions and it has many specialties, such as non-contact measurements, non-interfering etc.
4. Stable Automatic Optical Path Alignment System
The optical path alignment system can be corrected by one click, avoid adjustment difficulties caused by the optical path movement.
5. Multiple Size Distribution Models
Offer free choice standard model, RR distribution and Lognormal distribution. Can convert the volume distribution and individual number distribution freely.
SPRAY-319 particle size distributions & concentration ratio analysis analyzer Specifications
SPRAY-319A | SPRAY-319B | SPRAY-319C | ||
Standards | ISO13320-1 :1999, GB/T19077.1-2008, Q/0100JWN001-2013 | |||
Principle | Fraunhofer diffraction principle | |||
Instrument Structure | Split-type | |||
Testing Range | 1μm-500μm | 1μm-1000μm | 1μm-2000μm | |
Number of Channels | 50 pcs | 51 pcs | 58 pcs | |
Accuracy Error | <1% (Reference to CRM D50) | |||
Repeatability Error | <1% (Reference to CRM D50) | |||
Reproducibility | <1% (Reference to CRM D50) | |||
Data Acquisition Rate | ≧2KHZ | |||
Laser | LD Pump Laser; λ=532nm, p>40mw, life time>25000 hours | |||
Laser Safety | Class 3B | |||
Air Purging System | Equipped with airflow protection device, can effectively protect the lens, and avoid droplet pollution to lens in testing process. | |||
Sampling Mode | open style | |||
Optical Alignment System | automatic | |||
Working Temperature | 10-40°C | |||
Humidity | ≤75% | |||
PC System | Windows 7/8/10/11 (64 bits) with Office | |||
Output Parameters | Particle volume distribution curve, D10-D100 any parameters | |||
Testing Area Length | 0.1-10m/adjustable | |||
Lens Protection | Double gas episodic | |||
Outer Dimension | Pkg 1: L369*W295*H360mm, pkg 2: L858*W295*H360mm | |||
Power Supply | 220V, 50HZ | |||
Weight | 68 KG |
Operation Interface:
After the background testing, click on “energy spectrum test” in "test view", the system will display "test view". Observe the spectral curve and concentration, after the test result becomes stable, click the “save the results”. The system will automatically save the test result at the pre-set time intervals.