High Performance Distributed I/O Module BL201 with Profinet for S7-1500 PLC
USD $92.48 - $126.35 /Piece
Min.Order:1 Piece
Profinet Distributed I/O Module BL201 OEM ODM Manufacturer Compatible with Codesys /S7-1200 PLC
Distributed EtherCAT I/O Module BL202 for TwinCAT PLC Master Input/Output
EtherCAT Compact I/O Module BL202 OEM ODM Manufacturer for C200HS PLC
Distributed I/O System OEM ODM Manufacturer BL202 with EtherCAT for TwinCAT PLC
Modbus TCP I/O Module OEM ODM Manufacturer BL200 for DVP-ES2 PLC
Distributed Ethernet/IP I/O Module BL203 for KV-7000 PLC Compatible with EtherNet/IP Master
The BL201 coupler is a data acquisition and control system based on a powerful 32-bit microprocessor design with a Linux operating system.
The BL201 distributed I/O system consists of 3 parts: Coupler, I/O modules and terminal modules.
The communication between the node and the field devices (eg PLC) takes place via the Ethernet interface of the fieldbus coupler, and the communication between the fieldbus coupler and the I/O modules takes place via the local bus. The two Ethernet interfaces are internally integrated with a switch function, which can establish a linear topology without the need for additional switches or hubs.
The system needs to use the power module to provide 24VDC system voltage and 24VDC field voltage. Since two independent power supplies are used, the field voltage input interface and system voltage input interface of BL200 series couplers are electrically isolated from each other.
When assembling fieldbus node modules, each I/O module can be arranged in any combination, and it is not required to be grouped by module type.
A terminal module must be plugged into the end of a fieldbus node to ensure correct data transmission.
High reliability, easy expansion, easy setting, and convenient network wiring, these capabilities let users efficiently adapt the BL201 I/O system to a variety of industrial application.
Description | Model | Channel | Type |
Modbus-TCP I/O Coupler | BL200 | / | / |
Profinet I/O Coupler | BL201 | / | PROFINET |
EtherCAT I/O Coupler | BL202 | / | / |
Ethernet/IP I/O Coupler | BL203 | / | / |
OPC UA EdgeIO Controller | BL205 | / | / |
MQTT EdgeIO Controller | BL206 | / | / |
MQTT+OPC UA+Modbus TCP | BL206Pro | / | / |
BACnet/IP I/O Coupler | BL207 | / | / |
BACnet/IP+MQTT+OPC UA | BL207Pro | / | / |
8CH DI | M1081 | 8 | NPN (low level trigger) |
8CH DI | M1082 | 8 | PNP (high level trigger) |
16CH DI | M1161 | 16 | NPN (low level trigger) |
16CH DI | M1162 | 16 | PNP (high level trigger) |
4CH DO | M2044 | 4 | Relay |
8CH DO | M2081 | 8 | PNP |
8CH DO | M2082 | 8 | NPN |
16CH DO | M2161 | 16 | PNP |
16CH DO | M2162 | 16 | NPN |
4CH AI Single-Ended | M3041 | 4 | 0-20mA/4-20mA |
4CH AI Single-Ended | M3043 | 4 | 0-5V/0-10V |
4CH AI Differential | M3044 | 4 | 0-5V/0-10V |
4CH AI Differential | M3046 | 4 | ±5V/±10V |
4CH AO | M4041 | 4 | 0-20mA/4-20mA |
4CH AO | M4043 | 4 | 0-5V/0-10V |
4CH AO | M4046 | 4 | ±5V/±10V |
2CH RTD | M5021 | 2 | 3Wire PT100 |
2CH RTD | M5022 | 2 | 3Wire PT1000 |
2CH RTD | M5023 | 2 | 4Wire PT100 |
2CH RTD | M5024 | 2 | 4Wire PT1000 |
4CH TC | M5048 | 4 | TC(B/E/J/K/N/R/S/T) |
2CH RS485 | M6021 | 2 | RS485 |
2CH RS232 | M6022 | 2 | RS232 |
1CH RS485, 1CH RS232 | M6023 | 2 | RS485+RS232 |
Power module | M7011 | / | / |
Terminal module | M8011 | / | / |
Name | Description |
24V | System Power 24VDC |
0V | System Power 0VDC |
+ | Connections Field Supply 24 VDC |
+ | Connections Field Supply 24 VDC |
- | Connections Field Supply 0 VDC |
- | Connections Field Supply 0VDC |
PE | Grounding |
PE | Grounding |