TRICONEX 9566 7400150-370 3000540-380
Negotiable /Piece
Min.Order:1 Piece
HONG KONG SAUL ELECTRICAL LIMITED
TRICONEX 9566 7400150-370 3000540-380
TRICONEX 9566 7400150-370 3000540-380
Triconex is primarily used for emergency shutdown (ESD), fire protection and gas protection (F&G), burner management (BMS), High Integrity pressure protection (HIPPS), and turbomachinism control (TMC).
Triconex 8110 module rack, Triconex8111 expansion chassis, Triconex8121 expansion chassis rack. Power module 8310,8311,8312. Main processor module Triconex3008, Tricon Communication module (TCM), Ethernet (802.3) and the serial port (RS - 232 / RS - 485) Triconex4351A, Triconex4352A, Triconex4351B, Triconex4352B, Triconex4353, Triconex4354. Remote expansion module, interface module, digital input module.
I/O modules:
The digital input module receives discrete signals at these nominal voltages :115 VAC/VDC, 48 VAC/VDC and 24 VAC/VDC. The TMR module provides all voltages. Non-tmr modules are available only in 24vdc and 48vdc. Speed input and accumulation modules are also available.
The supervised digital output module generates discrete output signals of these nominal voltages, with diagnostic coverage of field circuits and load devices :115 VAC, 120 VDC, 48 VDC and 24 VDC.
The digital output module generates discrete output signals at these nominal voltages :115 VAC, 120VDC, 24 VDC and 48 VDC. Dual output modules are also available.
Interface module:
The HART analog input interface module acts as an interface to the 4-20 mA analog input point between the field HART smart device and the HART host software running on the PC.
The HART analog output interface module acts as the interface between the HART smart device in the field and the 4-20 mA analog output point where the HART host software runs on the PC.
Optical Fiber Remote Expansion Module (RXM) :
The extension chassis can be operated up to 7.5 miles (12 km) from the main chassis, with excellent anti-static and electromagnetic interference capabilities.
Processor Modules: The function of the processor module is to execute various instructions and process data. It can be divided into three modules: control unit, operation unit, and storage unit. Its role is to process instructions, execute operations, control time and process data, which directly affects the operation effect of the entire system
3008 Main Processor, 16 megabytes DRAM Triconex3008
Communication Hardware and Software
Tricon Communication Module (TCM), Ethernet (802.3) and serial (RS-232/RS-485) ports
Triconex4351A, Triconex4352A,
Triconex4351B, Triconex4352B
Triconex4353, Triconex4354