BLIIOT S270 Cellular IoT RTU 2DI 2DO 2AI 1TH for Barrier Lighting Solutions

BLIIOT S270 Cellular IoT RTU 2DI 2DO 2AI 1TH for Barrier Lighting Solutions

USD $89 - $149 /Piece

Min.Order:1 Piece

Supply Ability:
1000 Piece / Pieces per Month
Port:
SHENZHEN
Payment Terms:
T/T PayPal
Delivery Detail:
15 days

Quick Details View All >

Brand Name:
bliiot
Place of Origin:
China
Model Number:
S270

Shenzhen Beilai Technology Co., Ltd.

Business license
Main Products: Industrial IoT Gateways

Product Details

Cellular IoT RTU S270 is a wireless industrial IoT data monitoring and remote control unit, which is an ideal solution for remote data monitoring, data acquisition, remote control, and real time alarm. The RTU features 2 digital inputs, 2 analog inputs, 2 relay outputs, 1 temperature and humidity input. 
It is a cost effective IoT solution for Oil, Gas, Water, Weather, River, Flood, Energy, and other automatic monitoring system.



Key Features:

1) ARM® Cortex™-M4 32 Bit RISC Core, RTOS system;

2) Quadband 850/900/1800/1900Mhz GSM GPRS Module inside, 3G UMTS/HSDPA Modules are optional.

3) Widely Rated voltage range, 9~36VDC, Inbuilt large capacity rechargeable backup battery;

4) Large internal memory to save 200 historical records, USB port for configuration and upgrade firmware;

5) 2/4 analog inputs, 12bits resolution, supports 0-5V, 0-20mA, 4-20mA output transducers;


6) 2/4 solid relay outputs, rated capacity is 5A/30VDC,5A/250VAC;

7) 2/4 digital inputs, compatible to dry contact or wet contact inputs. Logic level: 0~0. 5V or short circuit treated as close, +3~30V or open circuits treated as open. One of the input can be used as counter, sampling frequency is 1Khz;

8) 1 temperature & humidity sensor input for monitoring onsite environment, the sensor model is AM2301, Measures temperatures from -40-80°C,0.5°C accuracy, Relative Humidity from 0-99RH%, accuracy is 3%;

9) All of the I/O ports with electromagnetic isolation protection;

10) 2 IP data centers, supports Modbus TCP,TCP/IP protocol over GPRS/3G network;

11) Automatically resend the data while GPRS/3G communication interrupt or failure, GPRS/3G failure will alert by SMS text to users.

12) Supports remotely restart the RTU, and configure& operate it by SMS commands remotely;

13) Supports over voltage protection and phase-reversal protection, provide DC power sources for external transducers or sensors to save wiring cost.

14) 10 SMS Alert and auto dial numbers for receiving alarm message, can program to receive specified alarm message. The authorized numbers also can dial to open the door or turn on/off machine with a free charge call at the specified time.


Technical Parameters:


Item

Reference Scope

DC Power supply

Standard adapter: DC 12V/1.5A  Range 9-36VDC

Power consumption

Standby:12V/70mA;  Working Max.: 12V/300mA

GSM/3G Frequency

850/900/1800/1900Mhz/3G (UMTS/HSDPA)

Transmit power

Class 4 (2W) at EGSM 900 and EGSM 850

Class 1 (1W) at GSM 1800 and GSM 1900

GPRS connectivity

GPRS multi-slot class 10

GPRS Data Transmission

GPRS data downlink transfer: max. 85.6 kbps

GPRS data uplink transfer: max. 42.8 kbps

Coding scheme: CS-1, CS-2, CS-3 and CS-4

TCP/IP stack

TCP,UDP

SIM interface

Supporting 3V SIM Card

External antenna

SMA Antenna interface, 50 Ohm

Alarm Phone Numbers

10 telephone numbers for SMS Alert and Dial while alarm.

Serial Interfaces

1 USB Port with ±15KV ESD Protection.

Protocols

SMS, GPRS UDP,TCP, Modbus TCP

Digital Inputs

2/4 Digital inputs, dry contact or wet contact. Logic level: 0~0. 5V or short circuit treated as close, +3~30V or open circuits treated as open. One of the input can be used as counter, sampling frequency is 1Khz;

Analog Inputs

2/4 analog inputs, 12bits resolution, supports 0-5V, 0-20mA, 4-20mA output transducers;

Temp.&Hum Inputs

AM2301, Range: Temperature: -40°C to +80°C, Humidity: 0~100%RH;

Relay Outputs

2/4 Solid Relay outputs, Rated Capacity: 5A/30VDC,5A/250VAC

Power Outputs

1 Port, for external device (Transducers or detectors or sensors).

Memory Capacity

Internal Memory inside, can save 200 historical events.

Backup Battery

3.7V 1200mAH, standby 8-16hours.

Temperature range

-10-+70 °C

I/O Isolation

Electromagnetic

Power input/Out

Over voltage protection and phase-reversal protection

Humidity range

Relative humidity 95% (condensation free)

Exterior dimension

168mm*113mm*26mm(external Maximum size)

Net Weight

1000 g

LED Indicator Definition

Power

RTU status indicator, LED ON when switched RTU on. OFF when switched RTU off.

Alarm

Alarm Indicator, alarm will ON and flick quickly. Normally is OFF;

Arm

Arm/Disarmed Indicator, Arm is ON, disarmed is OFF.

Run

RTU running status indicator, ON or OFF stands for RTU halted, flicks slowly stands for RTU running.

GSM/3G module indicator. Flicks quickly(less than 1second per time) stands for searching GSM/3G Network or no SIMCard inside or SIMCard connection is not good or cannot register to GSM/3G network successful. Flicks slowly (about 1sencond per time)stands for GSM/GPRS/3G stands for registered successful and GSM/3G Module standby.

Power Connector Definition

DC IN+

External DC Power input port, Connect to 1.5A@9~36V DC power, positive electrode.

DC IN-

External DC Power Input port, contact to negative electrode

DC Out+

Power source output port, positive electrode. Provides power from RTU to external transducers or sensors or detectors. The output voltage and current is the same as the power from DC IN inputs.

DC Out -

Power source output port, Negative electrode.

DIP Switch Definition

For S270, 2 and 3 switches are useless.

SET/RUN

For setting the RTU Mode is in Configuration Mode or Run mode.

Switch it to upside is Set Mode, under this mode, the user can use PC Configurator via USB cable to configure the RTU Parameters or Read Parameter settings.

Switch it to Downside is Run Mode, under this mode, the RTU is in Running mode.

0/V/mA

The 1st channel of analog input type switch. If not use this channel then no matter is upside or downside.

Switch it to upside stands for the 1st analog input should connect to 0~5V voltage output transducer.

Switch it to Downside stands for the 1st analog input should connect to 0~20mA or 4~20mA current output transducer.

1/V/mA~3/V/mA

The 2nd ~4th channel of analog input type switch. If not use this channel then no matter is upside or downside.

Switch it to upside stands for the related analog input should connect to 0~5V voltage output transducer.

Switch it to Downside stands for the related analog input should connect to 0~20mA or 4~20mA current output transducer.

Analog Input Definition

Analog inputs, 12bits resolution, supports 0-5V, 0-20mA, 4-20mA output transducers, please refer to abovementioned DIP Switch Definition to connect the correct transducers.

For S270, 2+/2- and 3+/3- ports are useless.

0+/0-

The 1st Channel Analog input. + stands for positive electrode, - stands for negative electrode.

1+/1- ~ 3+/3-

The 2nd ~4th Channel Analog input. + stands for positive electrode, - stands for negative electrode.

Digital Input Definition

Dry contact or wet contact. Logic level: 0~0. 5V or short circuit treated as close, +3~30V or open circuits treated as open. One of the input can be used as counter, sampling frequency is 1Khz.

For S270, 2/3 and GND ports are useless.

0

The 1st digital input, positive electrode. 

1~3

The 2nd ~ 4th digital input, positive electrode.

GND

GND for digital inputs, negative electrode.

ATN Port Connector Definition

ATN

GSM/3G Antenna connector, 50Ohm, SMA female.

USB Port Connector Definition

USB

USB port, for configuration and upgrading firmware and exporting historical data;

Temperature&Humidity Sensor Port Definitions

T/H

Temperature & Humidity sensor AM2301 inputs. Measurement Range: Temperature: -40°C to +80°C, Humidity: 0~100%RH.

Digital Solid Relay Output Connector Definition

Solid Relay inside for outputs, Rated Capacity: 5A/30VDC,5A/250VAC.

For S270, 2+/2- and /3+/3- ports are useless.

0+/0-

The 1st Channel Solid Relay Output. + stands for positive electrode, - stands for negative electrode.

1+/1- ~ 3+/3-

The 2nd ~ 4th Channel Solid Relay Output. + stands for positive electrode, - stands for negative electrode.

Model

GSM/3G

Precision

DIN

AIN

PT100

DO

T/H

Register

Record

Port

S270

V

12bit

2

2

0

2

1

X

200

USB


Contact Supplier

Ms. Echo Wu Chat Now

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Telecommunications > Communication Equipment > Wireless Networking Equipment