Product Features:
· Complies with GB4706.1 general requirements for the safety performance of household and similar electrical appliances, GB4706.2-GB4706.16, GB5956 special inspection requirements for household and similar electrical appliances, and national testing standards for household appliances.
Overall Specifications:
· Model BC9640: AC Withstand Voltage, Ground Resistance, Leakage Current, Power
· Model BC9650: AC Withstand Voltage, Ground Resistance, Leakage Current, Power, Insulation Resistance
· Model BC9660: AC Withstand Voltage, Ground Resistance, Leakage Current, Power, Insulation Resistance, Start Performance
Power Supply:
· AC 220V±10%, 50HZ±5%
Operating Environment:
· Temperature: 0-40℃, Humidity: 20-80%RH
Idle Power Consumption:
· Approximately 30W
Display Method:
· 5-inch LCD screen
Overcurrent Protection:
· Fuse, Circuit Breaker
Type of Test Instrument:
· Single-phase appliance
Alarm Method:
· Audible and visual alarm: Buzzer for pass/fail during testing
Test Groups:
· 20 memory groups, each with 6 test steps
External Dimensions (mm):
· Without base: W450xD565xH180
· With base: W450xD565xH220
Weight:
· Approximately 20Kg
AC Withstand Voltage Test:
· Output Voltage: AC 200~5000V
· Output Voltage Error: ± (Set Value × 2% + 3V)
· Breakdown Current Measurement Range: 0.02~10.00mA
· Breakdown Current Measurement Accuracy: ± (Measured Value × 2% + 0.03mA)
· Time Setting Range: 1~300S
Ground Resistance Test:
· Output Current: AC 10-25A
· Output Voltage Error: ± (2% of Reading Value)
· Breakdown Current Measurement Range: 10A gear, 5—600mΩ
· Breakdown Current Measurement Accuracy: ± (2% of Reading Value + 3mΩ)
· Time Setting Range: 1~300S
Leakage Current Test:
· Output Voltage: 1.06 or 1.11 times the input voltage (output by isolation transformer)
· Output Voltage Error: ± (2% of Reading Value + 3V)
· Leakage Current Measurement Range: 0.05~20.00mA
· Leakage Current Measurement Accuracy: ± (Measured Value × 2% + 0.03mA)
· Time Setting Range: 2~300S
Power Test:
· Output Voltage: 1.0 times the input voltage (output by isolation transformer)
· Voltage Measurement Accuracy: ± (Reading Value × 2% + 3V)
· Current Measurement Range: 0.1A~20.00A
· Current Measurement Accuracy: ± (Measured Value × 2% + 0.03A)
· Power Measurement Range: 0~6000W (or 2000W, 4000W)
· Power Measurement Accuracy: ± (Measured Value × 2% + 3W)
· Time Setting Range: 1~300S
Insulation Resistance Test (BC9650, BC9660):
· Output Current: DC 200~1000V
· Output Voltage Error: ± (Set Value × 2% + 3V)
· Insulation Resistance Measurement Range: 1.0~49.9MΩ~1000MΩ
· Insulation Resistance Measurement Accuracy: Below 50MΩ ± (Measured Value × 5% + 0.5MΩ)
· Above 50MΩ ± (Measured Value × 10% + 10MΩ)
· Time Setting Range: 1~300S
Start Test (BC9660):
· Output Voltage: 0.80 or 0.85 or 0.9 times the input voltage (output by isolation transformer)
· Voltage Measurement Accuracy: ± (Measured Value × 2% + 3V)
· Current Measurement Range: 0.1A~20.00A
· Current Measurement Accuracy: ± (Measured Value × 2% + 0.03A)
· Time Setting Range: 1~300S