PACKAGED REVERSE OSMOSIS + ELECTRODEIONIZATION FOR PURIFIED WATER
USD $10000 - $100000 /Set
Min.Order:1 Set
SHANGHAI CHONGYANG WATER TREATMENT EQUIPMENT CO.,LTD
Purified Water Systems:
*For purified Water Systems, microbiological specifications are not as clear. US Pharmacopeia, USP XXII specifications, as it complies with Federal Environmental Protection Agency regulations for drinking water, are recognized as being minimal specifications. There have been attempts by some to establish meaningful microbiological specifications for purified water. The CFTA proposed a specification of not more than 500 organisms per ml. The USP XXXII has an action guideline of not greater than 100 organisms per ml. Although microbiological specifications have been discussed, none (other than EPA Standards) have been established. Agency policy is that any action limit over 100 CFU/ml for a purified water system is unacceptable.
The purpose of establishing any action limit or level is to assure that the water system is under control. Any action limit established will depend upon the overall purified water system and further processing of the finished product and its use.
Functions Specification:
1.Adopt PLC+ Touch Screen automatic control mode ,stable &relible ,elegant appearance,one-click start ,simply operation.
2.Humanized 3D Design,in line with human engineering ,Designed height of touch screem,switches ,instrument meet average highth of people to conveniently operation.
3.There is dynamic monitoring screen for actions of any components Such as :water pump ,valve ,tank level .(you can upgrade remote monitoring if necessary.
4.Manual & Automatic mode conversion is convenient ,with special reminders to prevent misoperation.
5.It is important to the return water of purified water circulating pipe network are monitored on line ,in order to ensure the turbulence of the pipe network,the water return shall be kept at least 1m/s to reduce microbial growth of purified water pipe network.
6.Humanized alarm record and prompt function:There are some records in records of touch screen when filter material change cycle ,full water ,shortage water ,low pressure ,exceed pressure ; It appear abnormal sound light alarm when water quality ,pressure ,flow take place fault .
7.Set water quality correction function,with minimun waterquality warning function,there will be no sudden emergency.
8.Producing and supply water system are controlled separately ,for example ,don’t stop to produce or supply water if you’d like to replace consumables .
9.The Data of system runs can been saved, such as the abnormal record of the system running .
Company Name: Shanghai ChongYang Water Treatment Equipment CO.,LTD
Email : Sales@cy-waterequipment.com
Phone:+86 15900488030
Http://