Automotive Cables Testing Bench Top(Table)
8000 - 9000 /Piece
Min.Order:1 Piece
Shanghai Cleanknow Mechanical & Electronic Equipment Co., Ltd
Product Name | High Voltage Wire Harness Testing Bench Top |
Power | Electricity |
Type | OEM/Customized |
Brand Name | Cleanknow/Customized |
Model Number | |
Display | Monitor Size on demand |
Interface | USB Interface/Manual |
Overview:
The High Voltage Testing system has been specially developed for testing of high-voltage and data sensor cables. It conforms to international standards and is widely used in the cable assembly of automotive industry,etc.
Function and brief characteristics:
1: Equipped with over voltage protection, over current protection, leakage protection, which can greatly protect the safety of operator;
2. Arbitrary point to point testing;
3. Humanized software operation interface to help administrators to edit quick test procedures;
4. With administrator and operator double password , effectively ensure the control and security of the test program;
5. Synchronous recording of test data helps customers promptly understand product quality;
6. Printer function, freely to edit printing content;
7. Bar code scanning automatically loads test file and scan code test;
8. Voice broadcasting of test results.
Technical Specifications and Data:
AC | Output Voltage | |
Output | 0.05-5Kv | |
Measurement Accuracy | 1% + 5v | |
Display Accuracy | 2 V | |
Frequency | 50Hz/60Hz | |
Power | 150VA Max. | |
DC | ||
Output | 0.05-6Kv | |
Measurement Accuracy | 1% + 5v | |
Display Accuracy | 2 V | |
Power | 60 VA Max. | |
IR | Output | 0.05-1Kv |
Measurement Accuracy | 1% + 5v | |
Display Accuracy | 2 V | |
Insulation Resistance | ||
IR | Voltage | DC range: 0.05 - 1kV, voltage accuracy: 1.5% ± 5V |
Measurement Range | 1MΩ-50GΩ | |
Measurement Display Accuracy | 0.1MΩ | |
Measurement Accuracy | ≥500V: 1MΩ-1GΩ :±5%±10 counts, | |
1GΩ-10GΩ :±10%±10 counts, | ||
10GΩ-50GΩ :±15%±10 counts; | ||
≤500V:0.1MΩ-1GΩ:±10%±10 counts | ||
Arc Test | ||
Setting method | Programmable | |
The range of cutting off current | AC:1mA-15mA, DC: 1mA-10mA | |
Detection time | 10µs approx | |
Precision Resistance Test | ||
Continuity | Setting Range 0.1-500K | |
Resistance | 0.1-100KΩ; ±3%±0.1 | |
100K-1MΩ; ±5% | ||
0.01-75Ω; ±3%±0.01 | ||
ICR Test | ||
Frequency | 50Hz-1MHz optional | |
Test Signal Level | 0.1V-2V | |
Bias Current | Internal: 0-1A optional | |
External: 0-120A optional |