Medical Vaccine 2~8℃ Pharmacy Refrigerator NBC-5L416
Negotiable /Set
Min.Order:1 Set
Medical Vaccine 2~8℃ Pharmacy Refrigerator NBC-5L416
Introduction
Safer Storage Superior Temp. uniformity& Precise control
●Microcomputer temperature control.
●Dual display, temperature & Humidity.
●Temperature accuracy 0.1℃
●Temperature variation ≤2℃.
●Temperature uniformity ± 1℃
●USB port, temp. record traceable.
●Backup battery.
●Audible & visual alarm systems.
Reliable & stable performance
●International brand compressor.
●Forming technology. Micro-channel condenser .
●D+ heat exchange technology,
●High efficiency. and energy saving.
Humanized Design Friendly for daily use
●Electric heating glass door.
●Door self-close.
●Adjustable shelves with label holder.
●Porthole.
●Adjustable LED light.
●Wide voltage range design.
Features
Top cooling system
Strong cooling airflflow from the top to the bottom, works as an air curtain to block the external hot air from entering the refrigerator when door is opening, so as to prevent the temperature in the cabinet from rising rapidly, also contributes better temperature uniformity performance.
●Improves temperature uniformity performance by 40%.
●Max interior temperature difffference ±1℃.
●Prevent temperature rising rapidly when door is opening.
●Energy consumption 47% lower than similar sized normal pharmacy refrigerator .
DC Turbo Fan
●Decrease noise level by 8%.
●Integrated DC Turbo Fan works with smaller vibration and higher efficiency.
●Safer for daily use.
●No strong electric component in chamber, safer & more reliable.
Built-in air duct
Increase the effective interior space by 10%.
Less interior space occupancy.
Built-in air duct plus the Top cooling design, ensure temperature in the top of chamber is cool enough for storage.
Forming Technology
The fourth generation foaming agent More uniform density, Better insulation, more energy-saving. More reasonable foaming layer design, larger interior storage space.
Specification
NBC-5L416 | |
Storage Volume(L) | 416 |
Climate Class | N |
Temperature Range(°C) | 2~8 °C |
Cooling Type | Forced air coling |
Defrost Mode | Auto |
Voltage/Frequency(V/Hz) | 220-240V/50.60Hz |
Voltage/Frequency(V/Hz) | 110V/60Hz |
Cabinet Type | Upright |
Door Type | LOW E glass with Electrical heating door |
Refrigerant | R600a |
External dimension (W*D*H mm) | 690*653*1920 |
Internal dimension (W*D*H mm) | 595*514*1343 |
Model selection
Series | Under counter | 2nd Generation | 2nd Generation | 2nd Generation | 2nd Generation | |
Item | Model No. | NBC-5L126 | NBC-5L316 | NBC-5L416 | NBC-5L756 | NBC-5L1006 |
Dimensions | Load capacity (40HQ) | 48/162 | 71 | 47 | 38 | 21 |
Fridge Storage Volume(L) | 126 | 316 | 416 | 756 | 1006 | |
Product Dimensions (mm)(wxdxh) | 595*615*810 | 595*603*1920 | 690*653*1920 | 970*808*1920 | 1220*808*1920 | |
Interior Dimensions (mm)(wxdxh) | 505*467*620 | 500*464*1343 | 595*514*1343 | 880*634*1354 | 1130*634*1354 | |
Net/Gross Weight | 43/48 | 78/90 | 88/100 | 140/170 | 220/260 | |
Technical data | Cooling Type | Forced air cooling | Forced air cooling | Forced air cooling | Forced air cooling | Forced air cooling |
Defrost type | No frost | No frost | No frost | No frost | No frost | |
Climate Class | N | N | N | N | N | |
Refrigerant/Amount(g) | R600a/26g | R600/36g | R600/36g | R600a/48g | R600a/60g | |
Compressor type | Fixed frequency | Fixed frequency | Inverter | Inverter | Inverter | |
Sensor Qty | 3 | 6 | 6 | 6 | 6 | |
Product Performance | Temperature Range | 2 ~ 8℃ | 2 ~ 8℃ | 2 ~ 8℃ | 2 ~ 8℃ | 2 ~ 8℃ |
Temperature uniformity/°C | 2 | 2 | 2 | 3 | 3 | |
Temperature volatility/°C | 2 | 2 | 2 | 2 | 2 | |
Temperature Accuracy | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | |
Control | Controller | Microprocessor | Microprocessor | Microprocessor | Microprocessor | Microprocessor |
Display | LCD display | LED (Temperature&Humidity) | LED (Temperature&Humidity) | LED (Temperature&Humidity) | LED (Temperature&Humidity) | |
Electrical data | Rated Current(A) | 1 | 1.5 | 1.5 | 1.8 | 2.1 |
Rated Power(W) | 75 | 190 | 260 | 320 | 350 | |
Alarms | Power Failure Alarm | Y | Y | Y | Y | Y |
Sensor Failure Alarm | Y | Y | Y | Y | Y | |
Environment Temperature Alarm | N | Y | Y | Y | Y | |
Door ajar Alarm | Y | Y | Y | Y | Y | |
High Temperature Alarm | Y | Y | Y | Y | Y | |
Low Temperature Alarm | Y | Y | Y | Y | Y | |
Remote Alarm | Y | Optional | Optional | Optional | Optional | |
Accessories | Shelves/Drawers Qty | 2/1 | 5 | 5 | 10 | 10 |
Anti-condensation Door | LOW-E glass | Electrical heating | Electrical heating | Electrical heating | Electrical heating | |
Self-lock | Y | Y | Y | Y | Y | |
Label Card Holder | Optional | Y | Y | Y | Y | |
Cable Port | Y | Y | Y | Y | Y | |
Castors/type | N | 4/Omni-directional | 4/Omni-directional | 4/Omni-directional | 4/Omni-directional | |
USB | Optional | Y | Y | Y | Y | |
RS-485 Port | N | Y | Y | Y | Y | |
Printer | N | Optional | Optional | Optional | Optional | |
Backup Battery | Y | Y | Y | Y | Y | |
Backup Battery endurance | 24h | 24h | 24h | 24h | 24h |