electrical power fault indicator
electrical power fault indicator

electrical power fault indicator

Negotiable /Set

Min.Order:1 Set

Supply Ability:
5000 Set / Sets per Month

Zhuhai City Snova Technology Co., LTD

Business license
Business Type: Manufacturer
Zhuhai Guangdong China
Main Products: Earth Fault Indicator ,Cable Fault Indicator ,Overhead Line Ground Fault Indicator ,Short Circuit and Earth Fault Indicator ,Cable Temperature and Faults Sensor ,Industrial Dehumidifier ,Temperature and Humidity Controller ,Fault Passage Indicator ,Remote communication terminal ,Smart grid system

Product Details

Function description:

 

1. The data acquisition part,

 

1) three-phase current, collected and displayed from time to time

 

2) three-phase temperature, acquisition and display from time to time

 

3) grounding current, acquisition and display from time to time

 

2. The current signal part,

 

1) permanent open circuit fault, when the collected current value is greater than the current threshold value, * when the high current continues, it is greater than the reaction.

 

Time (Response time), * and the on-line current is cut off within the maximum fault time (longest Fault time) (that is, current)

 

When = 0), * and after the reclosing setting time, the current is still 0A, that is to say, it is a permanent open circuit fault.

 

Display mode: corresponding to A, B, C, led lamp, red flash once per second;

 

2) temporary open circuit fault, when the collected current value is greater than the current threshold value, * when the high current continues, it is greater than the reaction.

 

Time (Response time), * and the on-line current is cut off within the maximum fault time (longest Fault time) (that is, current)

 

When = 0), * and after the reclosing set time, the current value is not 0 A, that is, the temporary open circuit fault.

 

Display mode: correspond to A, B, C, light-emitting diode (led) lamp, and the red light flashes twice a second;

 

3) grounding fault, when the collected grounding current value is greater than the grounding current threshold setting value, it is grounding fault.

 

Display mode: corresponding to ground E, light-emitting diode (led) lamp, and the red light flashes once per second;

 

3. Part of the temperature signal,

 

Temperature fault alarm, when each phase collects the temperature value, which is greater than the temperature threshold setting value, that is, the temperature is too high to alarm.

 

The temperature LED lamps, flashing, and red flashing once a second, shall be provided.

 

4. Battery low voltage alarm, indication function,

 

When the battery voltage is lower than the chip operating voltage 0.1 volts, the electric alarm indication lamp shines. Flash every 3 seconds.

 

5. Input and remote control functions.


Contact Supplier

Mr. Andrewmao CEO Chat Now
Telephone
86-13570657698-8621065
Mobile
86-13570657698
Fax
86-13570657698-8618303
Address
Xiangzhou district Zhuhai,Guangdong
Whatsapp
8613570657698

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Electronic & Instrument Enclosures
Categories
Hi~