ADL300-EY Three Phase Prepaid Postpaid Electric Energy Meter 3x1(6)A AC via CTs Communication RS485 For Commercial Center
USD $84 - $90 /Kilogram
Min.Order:1 Kilogram
ADL300-EY Three-phase DIN Rail Prepaid Energy Meter
ADL100-EY single-phase pre-paid meters with intro-control, and ADL300-EY three-phase pre-paid meters with intro-control are used for calculating the single and three-phase active energy respectively on the frequency of 50/60 Hz The meter has functions of pre-paid, load controlling and RS485 communication, etc. meet the related technical requirements of electronic power meter in the IEC62053-21, IEC62053-22 standards.
Picture | Specification | Optional |
●Application:Prepaid&Postpaid ●Measurement:3-phase kWh, kVarh, Active Power, Reactive Power, Current, Voltage and etc ●Rated Voltage:3x380~456Vac L-L & 45~65Hz ●Rated Current:3x10(80)A AC (via direct connect); 3x1(6)A AC (via CTs) ●Communication:RS485 (MODBUS-RTU); Infrared ●Auto Control:Built-in Holding Relay for Switch On-off Control ●Standard&Certificate:CE | ● Multi-rate/tariff: 4 Tariff Rates and etc ● Secondary RS485 (MODBUS-RTU) |
Auto&Remote Switch Control ● Meter Supports Prepaid Mode & Postpaid Mode ● Auto Tripping when Balance Credit is below Zero (Prepaid Mode) ● Before Auto Tripping, Power Users can receive a Low Balance Alarm by SMS ● Remote Switch Control by using Prepaid System (Prepaid&Postpaid Mode) ● Prepaid&Postpaid Mode of Meters can be set using the Prepaid System | |
Local&Online Topping Up ● Topping up by RFID Card (Local) ● Topping up by Mobile APP (Online) ● Topping up by Prepaid System (Online) ● Low Balance Credit Alarm by sending SMS | |
Multi-rate&Multi-tariff ● 4 Tariff Rates (Spike, Peak, Flat, Valley kWh Unit Price) ● 14 Time Intervals by Day ● Set Unit Price of Electricity Consumption for different Time Periods of 1 Day |
Parameter | Description&Value | |
Measurement | kWh&kVarh | Total active kWh (bidirectional --positive and negative in total) |
Electrical Parameters | U (Voltage), I (Current), P (Active Power), Q (Reactive Power),S (Apparent Power), PF (Power Factor), F (Frequency) | |
Function Mode | Prepaid Mode | Meter will shut down the power once the credit balance is below zero. (Data like credit balance is saved in the meter) |
Postpaid Mode | Meter won't shut down the power once credit balance is below zero. (Can remotely control the meter to shut down the power by using Prepaid System) | |
Mode Change | Meter can change the mode between prepaid and postpaid by receiving the command from prepaid system | |
Control | Auto-tripping Control | Auto-tripping control is processed by the built-in high-capacity holding relay of the meters to realize on-off control of circuits breaker, also, this type of control will only be triggered when meter is in Prepaid Mode |
Remote Control | Remote control will be commanded by prepaid system. When users give the command of switch on-off to a certain meter, this command will be send to meters through wireless communication and finally meter will shut down or recover the power after receiving the command. This type of control can be done when meter is in Postpaid Mode | |
Multi-rate Multi-Tariff | Optional Function | 4 tariff rates (spike, peak, valley, flat); 14-time intervals by day |
Input Voltage | Rated Voltage | 3x380~456Vac L-L (Voltage signal input will be also served as power supply for meters) |
Frequency | 45~65Hz | |
Consumption | <4VA (each phase) | |
Input Current | Rated Current | 3x10(80)A AC (direct connection); 3x1(6)A AC (connected via CTs) |
Starting Current | 0.004 Ib (direct connection); 0.002 In (connected via CTs) | |
Accuracy | Measurement | Class 0.5s |
Clock | ≤0.5s/d | |
Pulse | Pulse Width | 80ms±20ms |
Pulse Constant | 6400imp/kWh (direct connection); 400imp/kWh (connected via CTs) | |
Communication | RS485 Interface | MODBUS-RTU Protocol |
Infrared | Used for Meter Reading | |
HMI | LCD Display | 8 bits section LCD display |
Keypads Programming | Setting of communication, current ratio and etc. | |
Mechanical Feature | Outline Dimension | 72mm*88mm*70mm |
Max Wiring Ability (with Flexible Cable) | 25mm2 | |
Environment | Operating Temperature | -25℃~+55℃ |
Storage Temperature | -40℃~+70℃ | |
Humidity | ≤95% (No condensation) | |
Altitude | <2000m |
ADL300-EY Three-phase four lines connect via CT | ADL300-EY Three-phase four lines direct connect |
connect via CT | direct connect |