Accuracy Class:
0.5

Acrel Electric Co., Ltd

Business license
Business Type: Manufacturer
Shanghai China
Main Products: Hall Sensor ,Split Core Current Transformer ,AC Energy Meter ,DC Energy Meter ,IoT Wireless Power Meter ,PV/Solar Inverter Energy Meter ,Data Center Power Meter ,Wireless Temperature Monitoring System and Sensors ,Medical IT Products ,City Utility Tunnel Moter Protector ,Electrical Insulation Safety Products ,Energy Quality Improvement

Product Details

AMC seres meters adopt AC sampling technology, which can measure the curent yvoltace,power, power factor and electric energy parameters in the power grioseparately. t can set the magnification through the panel membrane switch. The meters have RS485 communication interface, adopt Modbus protocol also canconvert the power signal into a standard DC analog signal.

Technical parameters
Value
Input
Connection
Single phase-2-wire,3-phase-3-wire,3-phase-4-wire
Frequency
45-65Hz
Voltage
Rating:single-phase:AC100V、400VT
hree-phase:AC3×57.7V/100V(100V)、3×220V/380V(400V)、3×380V/660V(660V)(96sizeonly)
Note:72 profile not suitable for high voltage applications
Overload:1.2foldrating{continuous):2foldratingfor1second
Power consumption:<0.5VA
Current
Rating:ACIA、5A
Overload:1.2 fold rating(continuous);10fold rating for 1second
Power consumption:<0.5VA
Output
Electric energy
Output mode:open-collect or photo-coupler pulse
Pulse constant:10000 imp/kWh(settable),see wiring diagram for details;
Communication
RS485 port,Modbus-RTU protocol, DLT645 protocol (versions 07 and 97),baud rate1200~38400
Function
Switching input
Dry contact input,built-in power supply;
Switching output
Output mode:Relay normally open contact output
Contact capacity:AC250V/3A、DC30V/3A
Analog output
1-5V,4-20mA
Accuracy class
Frequency:0.05Hz,Current,Voltage:0.2class,Reactive power:l.0class,Reactive Electric energy:l.0class, active power:0.5class, active
electric energy:0.5class,2-31th harmonic measurement:±1%
Power supply
AC/DC85-265V
power consumption≤10VA
Security
Powerfrequencywithstandvoltage
Between Power supply// Switching Output// Current Input// voltage Input and Transmitting// Communication// Pulse Output//
switching input AC2kV 1min;Between Power supply、switching output、Current Input、voltage Input AC2kV1min;Between
Transmitting、Communication、Pulse Output、switching inputAC1kV1min;
Insulationresistance
Input、Output end to machine enclosure>100MΩ
Environment
Temperature
work:-25°C~+65°C storage:-40°C~+80°C
Humidity
≤93%RH Non-condensing
Altitude
≤2500m

Contact Supplier

Ms. Shelly Zhang sales manager Chat Now
Telephone
86-21-18702111813
Mobile
86-18702111813
Fax
86-21-69155906
Address
No.253 Yulv Road, Jiading District, Shanghai
Whatsapp
86-18702111813

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Electrical Instruments > Energy Meters
Categories
Hi~