558320C.J20A Insocoat bearings
USD $1 - $10000 /Piece
Min.Order:1 Piece
LUOYANG MONTON BEARING SCIENCE & TECHNOLOGY CO.,LTD.
A-ARX60X320X756P Tandem Thrust Bearings for Twin Extruder Gearbox
ARX70X320X960-1PX1 Tandem Thrust Bearings for Twin Extruder Gearbox
01-17065-A 70X270X855 Tandem Thrust Bearings for Twin Extruder Gearbox
M2CT420900519 420X900X519Tandem Thrust Bearings for Twin Extruder Gearbox
UNITEC 181.0527 M5CT1565130Thrust Bearings for Twin Extruder Gearbox
NU330ECM/C3VL2071 150*320*65mm Insocoat bearings
Bearing | Dimension | Basic Dynamic Load Rating | Fatigue Limit Load | rated speed | ||||
dynamic | static | Reference speed | Limiting speed | |||||
d[mm] | D[mm] | B[mm] | C[kN] | C0[kN] | Pu[kN] | [r/min] | [r/min] | |
558320C.J20A | 100 | 215 | 60 | 900 | 965 | 100 | 2200 | 2600 |
Electric motors, generators and associated equipment are at risk when an electric current passes through their bearings. This can damage the contact surfaces of rolling elements and raceways in the bearings (electrical erosion) and rapidly degrade the grease. An additional risk in electric motors and generators comes from high frequency currents caused by the inherent stray capacitance.
The risk of damage increases where the application uses a frequency converter.
Insulated Insocoat bearings are designed to prevent electric current from passing through the bearing
have the external surfaces of either their inner or outer ring coated with an insulating aluminium oxide layer, by applying a sophisticated plasma-spray process for an outstanding quality finish
are a very cost-effective solution compared with other insulation methods.
Electrical pitting often occurs in the use of rolling bearings in high power electromotor, wind turbine generator and rail vehicles motor systems and cause sparks that damage the rolling contact surface, ultimately lead to bearing failure.
Electric insulated bearings therefore have been created and take the place of non-insulated bearings. we applies advanced surface modification process overlay a ceramic coating on the bearing ring, to insulate the electrical current flow into bearing substrate, so the electrical pitting is prevented and bearing's service life is extended.
It is significantly more cost-effective to provide for the use of electrically insulated bearings at the planning stage. As a result, customer benefit is increased through reduced maintenance costs and higher machine availability.
SAT series are the electrically insolated bearing products developed and marketed by us The insulation has a guaranteed breakdown resistance of at least 1000V AC or DC. We can also develop tailored modes for customer on types and precision levels, as well as higher electrical insulation.