Factory sales co2 supercritical extraction machine for lab and industrial use
Negotiable
Min.Order:1
Shanghai Genyond Technology Co., Ltd.
Grape Seed Oil Extraction with Mini CO2 Extraction Machine with Supercritical Extraction
Hemp Essential oil processing mini supercritical fluid co2 extraction extractor machine for oil
CHINA Essential Oil Distiller extraction machine Essential Oil Distillation Equipment extractor
CHINA GENYOND ultrasonic plant essential oil extraction equipment extraction machine
GENYOND Industrial essential oil distiller distillation extraction plant equipment for essential oil
CO2 extraction is suitable for extraction of fat-soluble and heat sensitive substances with high boiling point, and is suitable for fine seperation of different components.
The Super Critical fluid technology is a new-type separation technology in modern chemical seperation.The Super Critical extaction takes CO2 as the solvent.As CO2 fluid under Super Critical state has larger density and dielectric constant,large dissolvability against substances,which can change abruptly when pressure and temperature chnage therefore it has not only the selection of dissolvability against some substances,the separation of the solvent with the extracted substances is also easily.The super critial CO2 extraction is specially suitable for extraction of fat-soluble and heat sensitive substances with high boiling point,and is suitable for fine separation of different components,i.e.Super Critical fine distillation.
Take CO2 as the solvent to make extraction and purification upon a lot of products such as biological products,foodstuff and medicines.
This device usually be used for material extraction under the high pressure and suitable temperature (solid or fluid), Changing conditions in the separator to parse out dissolved substances in order to achieve the purpose of separation. The device is mainly composed of : extractionkettle, Separate kettle, CO2 high-pressure pump, entrainer pump, cooling system, CO2 basin, exergy transfer system, purification system, flowmeter, temperature-controlled system, safety protection device and so on. Attached device and the system can meet the needs of the main system of supercritical extraction and flow chart of requirements
Commonly, Supercritical fluid extraction device adopts CO2 as the extracting media. The advantages as follows:
1) Convenient in operation. Can be used widely.
2) With an excellent optional function. Extracts can be gained optionally by controlling the pressure and temperature.
3) Low operation temperature. Can be extracted near to the room temperature, especially fit for the extracting of thermo-sensitive elements. The possibility of oxidation when contact with oxygen and reaction when meet rays are eliminated. The natural flavor of the extracts can be kept.
4) Extracting media and extracts can be separated easily. No leftover of CO2 on the extracts after extracting operation.
5) CO2 is a nontoxic, flavorless, noncombustible and cheap compound and can be recycle used.
Type | Specification | Pressure | Combined type |
SFE120-50-01 | 1L | 50MPa | one extracting pot-two separating pot |
SFE120-50-02 | 2L | 50MPa | one extracting pot-two separating pot |
SFE121-50-01 | 1L | 50MPa | one extracting pot-two separating pots-one column |
SFE121-50-02 | 2L | 50MPa | one extracting pot-two separating pots-one column |
SFE121-50-05 | 5L | 50MPa | one extracting pot-two separating pots-one column |
SFE121-40-10 | 10L | 50MPa | one extracting pot-two separating pots-one column |
SFE121-40-24 | 24L | 50MPa | one extracting pot-two separating pots-one column |
SFE221-50-06 | 5+1L | 50MPa | two extracting pot-two separating pots-one column |
SFE221-40-11 | 10+1L | 50MPa | two extracting pot-two separating pots-one column |
SFE221-40-20 | 10+10L | 50MPa | two extracting pot-two separating pots-one column |
SFE221-50-48 | 24+24L | 50MPa | two extracting pot-two separating pots-one column |
SFE221-40-200 | 100L+100L | 50MPa | two extracting pot-two separating pots-one column |
SFE420-50-96 | (24+24)*2L | 50MPa | four extracting pot-two separating pot |
SFE420-40-200 | (50+50)*2L | 50MPa | four extracting pot-two separating pot |
APPLICATION | TYPE OF DESXRIPTION |
Agriculture Food | Extraction of pesticides and soil contaminants. Separation of fats and contaminats, flavors. |
Pharmaceutical | Extraction of active components, preparation of natual products, viamins. |
Cosmetic | Extraction of fragrances and oils. |
Laundry | Dry cleaning of garments. |
Mechanical | Degreasing parts, precision cleaning of high-value componets. |
A wide range of industries for the extraction of natural products for the food additives(such as ginger, large bolt, cinnamon, anise, hops, pepper, cumin,etc.), drugs(such as artemisia annua vegerarian, magnolia, angelia, etc.), health care(such as sea buckthorn, samara, pomegranate, lycopene, etc.) |
High quality of machine | Low price | Good after sale service | Warranty |
From the raw material, we just buy the top quality product. For motor, electronic part, we use top quality brand in the world. | For we buy high quantity raw material and spare part, we can get low price from our cooperated suppliers. So it reduce a lot cost. | Before the machine is ship, it will test well. We will send our engineers for installation within 10 days after the goods reach your factory. | We can offer 2 years warranty for free. Any problem for our machine, we can provide the spare parts for free. |
1 | 2 | 3 | 4 |
Contact us for more details michael - Genyond