IS220PDIAH1B control system
Negotiable /Bag
Min.Order:1 Bag
[The content of this link is sourced from brand manufacturers]
Phoenix PHOENIX Safety Module PSR-SPP-24DC/TS/S
Product Overview:
The freely configurable safety module has 20 safety inputs and 4 safety outputs, 4 signals, 2 clocks, and 2 grounding switch outputs, which can be diagnosed through the bus gateway and meet SIL 3, Cat Category 4/PL e, SIL 3 safety level, EN 50156, pluggable direct plug-in terminal blocks
Product specifications:
Product Type: Safety Equipment
Number of available expansion modules: 1 (maximum continuous current through PSR-TBUS: 4 A)
Overvoltage category: III
Pollution level: 2
Response time: maximum 30 ms (plus response time of PSR-TS-SDOR4)
Recovery time:<10 seconds
Maximum power consumption under rated conditions: 6372mW (at a=20, b=2, c=4, e=2, Iclock=100mA, Isignal=100mA, IOut/GND=2A, IOut/Out=2A)
Rated operating mode: 100% meets the conditions
Interface: USB
TBUS DIN rail for expansion modules and bus couplers
Rated control circuit power voltage US: 18 V DC 30 V DC (including all tolerances, including residual voltage)
Rated control circuit power voltage US: 24 V DC (A1/A2)
Rated control power supply current IS: typical value 110 mA
Limit continuous current: maximum 6 A (for loop current paths A1/A1 and A2/A2)
Delay time: typical value of 20 ms (depending on load, in case of voltage drop of US)
Contact information: 15359293870
WhatsApp:+86 15359293870
Contact person: KELLY
Email: geabbdcs@gmail.com 386353502@qq.com
Official website: http://www.geabb.com
Mechanical life: 10000000 operations
Installation: DIN rail quick installation according to EN 60715
Terminal connectors: hard or flexible
Screw terminal M20 x 1.5
Cable cross-section: 0.25 mm ²
Cable cross-section: 2.5 mm ²
Tightening torque of clamp: 0.6 Nm
Width: 22.5 mm
Height: 100 mm
Depth: 121 mm
Shell protection level: IP40
Gap protection level: IP54
Protection level of clamp and terminal: IP20
Ambient temperature: -25+ 60 ℃
Storage and transportation temperature: -40 ℃
Storage and transportation temperature:+85 ℃ MAX
Vibration resistance according to EN 60068-2-6:10 55 Hz, amplitude 0.35 mm, ± 15%
Impact resistance: 30 g/11 ms
Rated impulse withstand voltage: 4 kV
Conduction resistance: 40 Ω
Voltage, application category DC-12:24 VDC
Current, application category DC-12:0.1 A
Related models:
SRB211AN (V.2)
SRB211ST/CC (V.2)
SRB219IT-24VAC/DC