0.6/1kV XLPE Insulated LSOH Fire Resistant Shipboard Power
0.5 - 10 /Meter
Min.Order:200 Meters
Shanghai Nanyang Cable Co., Ltd.
·0.6/1kV XLPE Insulated LSOH Fire Resistant Shipboard Power
1.Standard:
IEC 60092-350-2014 IEC 60092-353-2016 GB/T 9331-2008
2.Application
Used for the power transmission in ships & on oil platform and other over - water buildings as well as power cables for port machineries.
3. Operational performance:
1).Rated Voltage:U0/U: 0.6/1kV
2). Minimum allowed bending radius for laying(D: outer diameter)
4D (D≤25mm);6D (D>25mm);
3). Maximum conductor temperature for continuous operation: ≤90℃
4). Minimum laying temperature:-20℃
4. Type & Model:
Type | Model |
CEPF/SC/NC | EPR Insulated Non-cross-linked Polyolefin Sheath LSOH Flame Retardant Marine Power Cable / SC/NC |
CEPJ/SC/NC | EPR Insulated Cross-linked Polyolefin Sheath LSOH Flame Retardant Marine Power Cable / SC/NC |
CEPF86/SC/NC | EPR Insulated Non-cross-linked Polyolefin Sheath Tinned Copper Wire Woven Armored Non-cross-linked Polyolefin Outer Sheath LSOH Flame Retardant Marine Power Cable/ SC/NC |
CEPJ85/SC/NC | EPR Insulated Cross-linked Polyolefin Sheath Tinned Copper Wire Woven Armored Cross-linked Polyolefin Outer Sheath LSOH Flame Retardant Marine Power Cable/ SC/NC |
CEPF96/SC/NC | EPR Insulated Non-cross-linked Polyolefin Sheath Galvanized Steel Wire Woven Armored Non-cross-linked Polyolefin Outer Sheath LSOH Flame Retardant Marine Power Cable/ SC/NC |
CEPJ95/SC/NC | EPR Insulated Cross-linked Polyolefin Sheath Galvanized Steel Wire Woven Armored Cross-linked Polyolefin Outer Sheath LSOH Flame Retardant Marine Power Cable/ SC/NC |
CEPFR/SC | EPR Insulated Non-cross-linked Polyolefin Sheath LSOH Flame Retardant Marine Flexible Power Cable/ SC |
CEPJR/SC | EPR Insulated Cross-linked Polyolefin Sheath LSOH Flame Retardant Marine Flexible Power Cable/ SC |
CJPF/SC/NC | XLPE Insulated Non-cross-linked Polyolefin Sheath LSOH Flame Retardant Marine Power Cable/SC/NC |
CJPJ/SC/NC | XLPE Insulated Cross-linked Polyolefin Sheath LSOH Flame Retardant Marine Power Cable/SC/NC |
CJPF86/SC/NC | XLPE Insulated Non-cross-linked Polyolefin Sheath Tinned Copper Wire Woven Armored Non-cross-linked Polyolefin Outer Sheath LSOH Flame Retardant Marine Power Cable/ SC/NC |
CJPJ85/SC/NC | XLPE Insulated Cross-linked Polyolefin Sheath Tinned Copper Wire Woven Armored Cross-linked Polyolefin Outer Sheath LSOH Flame Retardant Marine Power Cable/ SC/NC |
CJPF96/SC/NC | XLPE Insulated Non-cross-linked Polyolefin Sheath Galvanized Steel Wire Woven Armored Non-cross-linked Polyolefin Outer Sheath LSOH Flame Retardant Marine Power Cable/ SC/NC XLPE |
CJPJ95/SC/NC | XLPE Insulated Cross-linked Polyolefin Sheath Galvanized Steel Wire Woven Armored Cross-linked Polyolefin Outer Sheath LSOH Flame Retardant Marine Power Cable/ SC/NC XLPE XLPE |
CJPFR/SC | XLPE Insulated Non-cross-linked Polyolefin Sheath LSOH Flame Retardant Marine Power Cable/ SC |
CJPJR/SC | XLPE Insulated Cross-linked Polyolefin Sheath LSOH Flame Retardant Marine Power Cable/ SC |
5.Fire Resistance:
Type of SC: Up to standard of Class A Combustion Requirements of Bunched Flame Retardant as per IEC 60332-3 (IEC 60754-1,2; IEC 61034-1,2; IEC 60684-2)
Type of NC: Up to standard of Class A Combustion Requirements of Bunched Flame Retardant as per IEC 60331-21 &
IEC 60332-3 (IEC 60754-1,2; IEC 61034-1,2; IEC 60684-2)
6. Specs. Range
Core No. | Nominal Cross Section(mm2) |
1 | 1-300 |
2 | 1-120 |
3 | 1-185 |
4-37 | 1-2.5 |
Remarks: Special customizing is available.