Item No. | Detailed Specifications |
SK-350P | Dimension(L*W*H)mm | 560*830*1718 |
Output(lb/24hr) | 350 lb=159 kg |
Bin Capacity (lb) | 230lb=105kg |
Voltage (V/Hz) | 220/50/60 110/60 |
Power (W) | 1000 |
Condenser Unit | Air/Water |
Refrigerant | R290 |
Net Weight of Main Machine(kg) | 50 |
Net Weight of Ice Bin(kg) | 35 |
Gross Weight of Main Machine(kg) | 54 |
Gross Weight of Ice Bin(kg) | 40 |
Paking Dimension(L*W*H)mm of | 655*750*620 |
Main Machine |
|
Paking Dimension(L*W*H)mm of Ice bin | 645*890*1055 |
SK-420P | Dimension(L*W*H)mm | 560*830*1718 |
Output(lb/24hr) | 420 lb=191 kg |
Bin Capacity (lb) | 230lb=105kg |
Voltage (V/Hz) | 220/50/60 110/60 |
Power (W) | 1100 |
Condenser Unit | Air/Water |
Refrigerant | R290 |
Net Weight of Main Machine(kg) | 52 |
Net Weight of Ice Bin(kg) | 35 |
Gross Weight of Main Machine(kg) | 56 |
Gross Weight of Ice Bin(kg) | 40 |
Paking Dimension(L*W*H)mm of |
Main Machine |
Paking Dimension(L*W*H)mm of Ice bin | 645*890*1055 |
Loading Qty (20GP/40GP) | 26 / 52pcs |
SK-500P | Dimension(L*W*H)mm | 760*830*1718 |
Output(lb/24hr) | 500 lb = 227 kg |
Bin Capacity (lb) | 275lb=125kg |
Voltage (V/Hz) | 220/50/60 110/60 |
Power (W) | 1240 |
Condenser Unit | Air/Water |
Refrigerant | R290 |
Net Weight of Main Machine(kg) | 66 |
Net Weight of Ice Bin(kg) | 45 |
Gross Weight of Main Machine(kg) | 70 |
Gross Weight of Ice Bin(kg) | 50 |
Paking Dimension(L*W*H)mm of | 845*750*620 |
Main Machine |
|
Paking Dimension(L*W*H)mm of Ice bin | 850*890*1055 |
|
Loading Qty (20GP/40GP) | 21 / 42pcs |
SK-700P | Dimension(L*W*H)mm | 760*830*1718 |
Output(lb/24hr) | 700lb = 318kg |
Bin Capacity (lb) | 275lb=125kg |
Voltage (V/Hz) | 220/50/60 |
Power (W) | 1420 |
Condenser Unit | Air/Water |
Net Weight of Main Machine(kg) | 66 |
Net Weight of Ice Bin(kg) | 45 |
Gross Weight of Main Machine(kg) | 71 |
Gross Weight of Ice Bin(kg) | 50 |
Paking Dimension(L*W*H)mm of |
Main Machine |
Paking Dimension(L*W*H)mm of Ice bin | 850*890*1055 |
|
Loading Qty (20GP/40GP) | 21 / 42pcs |
SK-1000P | Dimension(L*W*H)mm | 760*830*1893 |
Output(lb/24hr) | 1000 lb=455 kg |
Bin Capacity (lb) | 275lb=125kg |
Voltage (V/Hz) | 220/50/60 |
Power (W) | 2300 |
Condenser Unit | Air/Water |
Net Weight of Main Machine(kg) | 85 |
Net Weight of Ice Bin(kg) | 45 |
Gross Weight of Main Machine(kg) | 90 |
Gross Weight of Ice Bin(kg) | 50 |
Paking Dimension(L*W*H)mm of | 848x696x811 |
Main Machine |
Paking Dimension(L*W*H)mm of Ice bin | 850*890*1055 |
|
Loading Qty (20GP/40GP) | 18 / 36pcs |
|
The working principle
Through the make-up water valve, water is automatically entered into a water storage tank, and then the flow control valve through the pump to the water to the tap head, where water spray evenly to the ice on the surface, like water through the wall of ice and water is cooled to freezing point, and were not frozen water evaporation will through porous slot into the water storage tank, resume work cycle.
When THE ICE REACHES THE REQUIRED THICKNESS (THE thickness can be ARBITRARILY SELECTED by the OPERATOR/user), the HOT gas discharged from the compressor is REdirected back to the clamping wall of the ice maker to replace the low-temperature liquid refrigerant. This creates a thin film of water between the ice and the wall of the evaporation tube, which will lubricate the ice as it falls freely into the tank below by gravity. The water produced during the ice harvesting cycle will be returned to the storage tank through the porous tank, which also prevents the wet ice from being discharged by the machine.
1. The chilled water of the water storage tank is continuously circulated through the evaporator of plate or grid with a pump;
2, the compressor after operation by inspiration-compression - exhaust - condensation (liquefaction)- throttling - and then in the evaporator to -10 to -18 degrees of low temperature evaporation heat absorption vaporization. Frozen water in the temperature of 0 degrees Celsius constantly on the surface of the lower temperature evaporator ice. When the ice condenses to a certain thickness, the evaporation temperature of the refrigerant reaches the set temperature of the temperature control, that is, the defrosting solenoid valve is connected to the form of heat pump deicing, and then the next cycle.