Acrel ACR10R-D16TE4/C45 Photovoltaic Applications Bidirectional Electricity Meter With Modbus-Rtu Protocal
CNY 1078 - 1200 /Piece
Min.Order:1 Piece
Technical Parameter
Function/Model | ACR10RH-DxxT(R)E4 ACR10RH-DxxT(R)E3 | |
Display mode | LCD(Field LCD) | ■ |
Measuring parameter | Current/voltage/frequency/power facto | ■ |
Active power/reactive power/apparent power | ■ | |
Four-quadrant electric energy measurement | ■ | |
Maximum demand | □ | |
Multiple-rate electric energy measurement | □ | |
Power quality monitoring | Total harmonic content | ■ |
subharmonic(2-31 times) | ■ | |
Data logging | Incident record | □ |
Display mode | Alarm | □ |
Built-in clock | □ | |
Communication | RS485 interface | ■ |
Optional function (choose one) | J(2DO) | A1+(B1 or C1) (4DI+2DO or 4DI+EP)* |
Technical parameters | Indicators | |||
Input | Net work | 3-phase 3-wire,3-phase 4 wire | ||
Frequency | 45~65Hz | |||
Voltage | Rating:AC 57.7V/100V(100V),220V/380V(400V) | |||
Overload:1.2-fold rating(continuous);2-fold rating/1second | ||||
Consumption:<0.2VA | ||||
Current | Rating: 80A,120A,200A .etc(See specific product specifications,special parameters can be customized) | |||
Overload:1.2-fold rating(continuous);10-fold rating/1 second | ||||
Consumption:<0.2VA | ||||
Output | Electric energy | Output mode: Open-collector photocoupler pulse, two-way output | ||
Three-phase | Pulse constant:4000,8000imp/kWh | |||
Communication | RS485 interface, Modbus-RTU Protocol | |||
Display mode | LCD | |||
Function | Switching | Input | Four-way dry contact input | |
Output | Output mode: two-way relay nO contact output | |||
Contact capacity:AC 250V/3A,DC 30V/3A | ||||
Measuring accuracy | Frequency0.05Hz,reactive electric energy1class,other 0.5class | |||
Power supply | AC85~265V or DC100~350V;DC24V(±10%);DC48V(±10%) Consumption≤10VA | |||
Safety | Power-frequency withstand voltage | Power frequency withstands voltage between Auxiliary power and switch volume output and current input and voltage input and communication and pulse output and switch volume input terminal is AC2kV 1min; Power frequency withstand voltage between auxiliary power and switch volume output and current input voltage input terminal is AC 2kV/1min; Power frequency withstand voltage between communication and pulse output and switch volume input terminal is AC 1kV/1min; | ||
Insulation resistance | Input, Output terminal to housing>100MΩ | |||
Environment | Working temperature:-10℃~+55℃;Storage temperature:-20℃~+70℃ Relative humidity:5%~95% No condensation;Altitude:≤2500m |
wiring