Guangzhou Yingpeng Infrared Flame Detector
Negotiable /Box
Min.Order:1 Box
Guangzhou Yingpeng Optoelectronics Technology Co., Ltd
Name: Point type infrared flame detector
Model: A705/IR2
Sensors: Ruitan AE-S708/4 and AE-S708/5 infrared pyroelectric sensors
Optical window housing: White gemstone (AI203)
Material: Aluminum alloy
Forming process: die-casting
Coating process: surface electrostatic powder spraying, internal metal passivation treatment
Weight: ≤ 1kg
Explosion proof grade: Exd II CT6
Protection: IP66
Working current: monitoring ≤ 15mA, alarm status ≤ 35mA
Preheating time: 60s after power on
Fault alarm: When a flame is detected in the monitored area, the detector enters a fire alarm state;
The fire alarm input relay acts and the yellow fault indicator light illuminates;
Alarm threshold: When both fire and fault occur simultaneously, fire alarm takes priority;
1-3 levels adjustable (set by electromagnetic rod)
The number of times the green light flashes during monitoring indicates the alarm threshold.
Alarm delay: 0-30S adjustable (set to 0S at the factory)
Drift compensation: sensor hardware compensation and intelligent software compensation combined mode
Can effectively compensate for drift caused by temperature, environmental changes, and long-term operation of components
Interference source suppression: can effectively suppress the influence of non flame interference sources, such as sunlight (direct and reflected)
Commonly used artificial light sources, background radiation sources, thermal moving objects, welding, etc.
indicator light:
Monitoring status: green light flashing
Fire alarm status: Red light always on
Fault status: yellow light constantly on
Output:
Fire alarm relay, acting upon alarm, output contact 3A@30VDC 3A@250VAC
Fault relay, acting upon fault, output contact 3A@30VDC 3A@250VAC
Serial communication interface
Working temperature: -10 ℃~+55 ℃ or -40 ℃~+70 ℃ (reinforced)
Working humidity: ≤ 95% HR, no condensation
Storage temperature: '-40 ℃~+85 ℃
Settings: Using a PC and specialized software, the alarm parameters of the detector can be set through the serial communication port;
Alarm mode, alarm threshold, alarm delay time, requiring professional operation and password authorization.
Suggested setting: Use the magnet at hand to control the built-in reed tube to adjust alarm sensitivity
Record query: Using a PC and specialized software, the internal records of the detector can be set through the serial communication port.
Factory settings: alarm threshold and delay time. User settings (default factory settings): alarm threshold and alarm delay time.
Factory functions: maintenance, calibration, compensation parameter information, qualification identification, software version, product ID, etc.
Professional operation and password authorization are required.
Power supply: minimum: 18VDC (customizable 12VDC)
Standard: 24VDC
Maximum: 30VDC
Functional characteristics
1. Developed based on the principle of dual wavelength infrared detection.
2. Built in high-performance 32-bit microprocessor computing chip
3. Detection direction can be adjusted 360 degrees
4. Infrared observation angle of 110 degrees, axis detection distance of up to 35 meters
5. Patent signal processing algorithm
6. Equipped with two fire alarm and fault relay outputs
7. Reliable system fault self-diagnosis function.
8. Exd IIC T6 explosion-proof grade, suitable for Zone 1 and Zone 2 hazardous locations.
Executive standards:
GB15631-2008 "Special Fire Detectors"
GB3836.1-2000 Electrical Equipment for Explosive Gas Atmospheres Part 1: General technology Requirements
GB3836.1-2000 "Electrical Equipment for Explosive Gas Atmospheres" Part 2: Flameproof Type "D"