Guangzhou Yingpeng explosion-proof air energy water unit 15 pieces
Negotiable /Case
Min.Order:1 Case
Guangzhou Yingpeng Optoelectronics Technology Co., Ltd
Guangzhou Yingpeng explosion-proof air energy water unit 15 pieces
Guangzhou Yingpeng explosion-proof air energy water unit 20 pieces
Guangzhou Yingpeng explosion-proof air energy water unit 30 pieces
Guangzhou Yingpeng explosion-proof vertical cabinet cooling and dehumidifying machine 10KG
Guangzhou Yingpeng explosion-proof vertical cabinet cooling and dehumidifying machine 20KG/H
principle
The air energy heat pump operates according to the "inverse Carnot" principle and the inverse Carnot cycle principle. By operating the compressor system, it absorbs heat from the air to produce hot water. The specific process is as follows: the compressor compresses the refrigerant, and after compression, the temperature rises to a higher level. After passing through the condenser in the water tank, hot water is produced. After heat exchange, the refrigerant returns to the compressor for the next cycle. In this process, the air heat is absorbed by the evaporator and introduced into the refrigerant, which is then introduced into the water to generate hot water. A new generation of water heaters heated by compressor air, namely air energy heat pump water heaters. Visually speaking, the "outdoor unit" compresses air like an air pump, causing the air temperature to rise, and then conducts heat into the indoor water storage tank through a liquid that will boil at -17 ℃, and then releases the heat and conducts it into the water.
Product parameters;
model; RSJ45R
Suitable for the ambient temperature range- 12~43℃
Maximum outlet water temperature; 60℃
20 ℃ ambient heating capacity; 45kw
20 ℃ ambient temperature water yield; 968L
-7 ℃ ambient heating capacity; 22KW
-7 ℃ ambient temperature water output; 555L
Power Supply; 380V-50HZ
Operation control; Microcomputer fully automatic control, running status display, abnormal status alarm
Safety devices; High and low voltage switch, anti freezing switch, overcurrent protection switch, compressor overheat protection device compressor; 1 unit
cryogen; R410a
Inlet and outlet pipes; DN40
Water volume; 10.1m3/H