Wrapping film Peel Cling Tester for Stretch Wrap Film ASTM D5458
USD $1000 - $4000 /Set
Min.Order:1 Set
Principle:
Peel cling testing requires two different types of samples. The first sample is larger piece as backing placed on test bed. The second piece is a smaller strip which is peeled off the larger sample.
The larger sample is wrapped fixed on the incline surface and the smaller sample is attached to a clip, connected with loadcell. It's pulled after it's clung to the large sample and the force is measured during the pulling.
We recommend the way described in ASTM D5458, which, during the test, reduces the influence of frictions in a tensile tester and pulley.
It complies with ASTM D 5458, BB/T 0024.
ASTM D 5458 Standard Test Method for Peel Cling of Stretch Wrap Film
ASTM D 4649 Standard Guide for Selection and Use of Stretch Wrap Films
Technical features
1. 7 inch TFT touch screen operation (human machine interface)
2. PLC control unit inside for stable performance
3. Precision ball screw for accurate speed & displacement.
4. Test speed is adjustable.
5. Different connection of loadcell with sample eliminates the interference caused by the friction and gravity of pulley and string, which are commonly used in traditional method.
6. Limiting device and automatic returning.
7. Real time display of test curve, peak value recording.
8. Supportive line of elongation rates, 50%, 100% and 200%.
9. Microprinter
10.Coefficient of friction function can be added (Optional)
Parameters
Test Range: 5N ( or other range)
Speed Range: 125mm/min( or 1-500 mm/min settable)
Power AC 220V 50Hz