acrel ADW300/4G 4G energy meter wireless IoT energy meter
Negotiable
Min.Order:1
Acrel ACLP10-24 DC Auxiliary Power Supply module transfer AC220V to DC24V
DC multi functional digital smart power meter for Solor PV Power Distribution din rail mounted
digital electrical meter for 1000VDC industrial control system Din rail installation
Multifunction DC Power meter LED digital dc volt amp kwh panel meter PZ72-DE
Digital DC voltmeter measuring DC0-1000V AMC72-DV/M panel voltage meter 4-20mA analog output
digital dc current meter AMC72-DI Programmable DC Ammeter with low factory price
Function | Description | ||||||
Measurement of Energy | kWh (positive and negative) | ||||||
kvarh (positive and negative) | |||||||
A,B,C 3-phase positive kWh | |||||||
Electric Parameters | U, I, P, Q, S, PF, Hz | ||||||
Harmonic | THDv, Harmonic on 2nd-31st | ||||||
Pulse output | Active pulse output | ||||||
3-Phase Imbalance | Voltage imbalance,current imbalance | ||||||
Display | LCD display with 8 digits | ||||||
Wireless Comms. | 4G, WiFi, LoRA, NB-IoT (Optional), Support MQTT, MODBUS-TCP protocol | ||||||
Wired Comms. | RS485 interface with MODBUS-RTU protocol (Standard) | ||||||
Swtich | 4 DI & 2 DO | ||||||
Residual Current | 1 way residual current measurement | ||||||
Temperature | A,B,C,N. 4 ways temperature measurement |
Parameter | Description&Value | ||||||
Input Voltage | Nominal Voltage | For High Voltage: 3×57.7~69.24Vac L-N & 100~120Vac L-L (Paired with PT) ------------------------------------------------------------------------------------ For Low Voltage: 3×220~264Vac L-N & 3x380~456Vac L-L (Direct Connect) 3×380~456Vac L-N & 3x660~792Vac L-L | |||||
Frequency | 50Hz~60Hz | ||||||
Comsumption | <0.5 VA (Each phase) | ||||||
Input Current | 3×1(6)A | ||||||
Swtich | 1‰ Ib (Class 0.5S),4‰ Ib (Class 1) | ||||||
Residual Current | <1VA (Each phase) | ||||||
Auxiliary Power | Power Supply | 85~265Vac L-N | |||||
Power consumption | <2W | ||||||
Measurement Performance | Standard | IEC 62053-22:2003,IEC 62053-21:2003 | |||||
Active Power Accuracy | Class 0.5S(ADW300) Class 1(ADW300W) | ||||||
Temperature Measuring Accuracy | ±2℃ | ||||||
Pulse | Width of pulse | 80±20ms | |||||
Pulse constant | 6400imp/kWh , 400imp/kWh | ||||||
Communication | Wireless Communication | 4G (built in world-wide 4G module for global server frequency bands) WiFi (2.4GHz), LoRa, NB-IoT, RS485 (standard MODBUS-RTU) | |||||
Infrared Communication | Constant baud rate 1200 | ||||||
Interface | RS485(A+、B-) | ||||||
Connection Mode | Shielded twisted pair conductors | ||||||
Protocol | MODBUS-RTU | ||||||
Environment | Operating Temperature | -20℃~55℃ | |||||
Storage Temperature | -40℃~70℃ | ||||||
Humidity | ≤95% (No condensation) | ||||||
Altitude | ≤2000m |