ADL400 Three Phase Energy Meter
Product Description
ADL400 din rail energy meter adopts DIN35mm din rail installation with LCD display,it can measure electric parameters and has energy pulse output, RS485 communication,which has the advantages of small size, high precision, good reliability and convenient installation.
● Rated Current: 1 (6) A, 10 (80) A
● Rated Voltage: AC220V/380V, AC230V/400V
● RS485(MODBUS-RTU) Communication
● 12 digits LCD Display; 35mm DIN Rail Installation
● 2~31st Harmonic Measurement
● kWh Class 0.5S
● Rated Voltage: AC220V/380V, AC230V/400V
● RS485(MODBUS-RTU) Communication
● 12 digits LCD Display; 35mm DIN Rail Installation
● 2~31st Harmonic Measurement
● kWh Class 0.5S
Characteristic
Rated U : AC3×100V、 3×380V、3×57.7/100V、 3×220/380V
Rated I : 3×1(6)A,3×10(80)A
Display : LCD display U、I、P、Q、S、PF、F
Option function/C: RS485,MODBUS-RTU
Option function/F : Multi tariff energies
Accuracy
kWh: Class 0.5, kVarh:Class 2Frequency
50/60HZ(Optional),range: 45~65HZ
Pulse output
Pulse output kWh/kvarh
Consumption
<10VA(Single phase)
Installation: DIN 35mm
Dimension(L*W*H): 72*90*65mm
Clock: ≤0.5S / per day
Starting current: 0.1%Ib
Dimension(L*W*H): 72*90*65mm
Clock: ≤0.5S / per day
Starting current: 0.1%Ib
Communication:RS485(Modbus-RTU)
Working temperature: -25℃~55℃
Specification
Specification | |||||||
Reference voltage | 3×100V、 3×380V、3×57.7/100V、 3×220/380V | ||||||
Consumption
| <10VA | ||||||
Impedance | >2MΩ | ||||||
Accuracy | Error±0.2% | ||||||
Current | Reference current | 3×1(6)A,3×1(6)A(Outlay transformer) | |||||
Accuracy class | Error±0.2% | ||||||
Consumption | <1VA | ||||||
Power | Active, reactive, apparent power, error±0.5℅ | ||||||
Display | LCD | ||||||
Frequency | 45~65Hz,Error±0.2% | ||||||
Communication | RS485, Modbus-RTU protocol | ||||||
Adapt 4 time zones, 2 time interval lists, 14 time interval by day and 4 tariff rates;Max demanded kWh and time happened;Frozen data on last 48 month,last 90 days; | |||||||
Operation Temperature | -10 ºC~+55 ºC | ||||||
Storage Temperature | -40 ºC ~+70 ºC | ||||||
Altitude | ≤ 2000m | ||||||
Relative humidity | ≤95%RH, no condensation, without corrosive gas |
Dimension
Note:The torque of direct connect should not be greater than 4.0N·m,and the torque of connect via CT should not be greater than 2.0N·m。
Wiring
Company Profie