ADL3000-E/CT Three-phase Multi-function DIN Rail Energy Meter (with External CTs)
Products Description
● Measurement: 3-phase kWh (0.5S), Active Power, Reactive Power, Current, Voltage, Harmonic and etc
● Voltage Rating: 3x220/380V, 3x57.7/100V (3P4W); 3x380V, 3x100V (3P3W)
● Current Rating: 3x10(100)A; 3x1(6)A
● Frequency: 45~65Hz
● Commnunication: RS485 (MODBUS-RTU) and Infrared
● Multi-rate: Spike, Peak, Valley and Flat kWh
● Extra Function: Cable Temperature Measurement and DO/DI
● Display: LCD (8 digits)
● Dimension: 127*88*70mm (L*W*H)
● Wiring: 3-phase 4wire; 3-phase 3-wire
● Installation: 35mm DIN Rail
● Standard&Certificate: IEC; CE; EAC
● Voltage Rating: 3x220/380V, 3x57.7/100V (3P4W); 3x380V, 3x100V (3P3W)
● Current Rating: 3x10(100)A; 3x1(6)A
● Frequency: 45~65Hz
● Commnunication: RS485 (MODBUS-RTU) and Infrared
● Multi-rate: Spike, Peak, Valley and Flat kWh
● Extra Function: Cable Temperature Measurement and DO/DI
● Display: LCD (8 digits)
● Dimension: 127*88*70mm (L*W*H)
● Wiring: 3-phase 4wire; 3-phase 3-wire
● Installation: 35mm DIN Rail
● Standard&Certificate: IEC; CE; EAC
ADI3000-E/CT 3-phase multifunction energy meter is featured of external current transformers which tremendously ease the modification project. The external CTs can be dirrectly connected with other CTs' line which is already on site.
Other that this, the other features of ADL3000-E/CT and ADL3000-E pretty much remain the same except for input current of direct connection.
Semi-Automatic PET Bottle Blowing Machine Bottle Making Machine Bottle Moulding Machine
PET Bottle Making Machine is suitable for producing PET plastic containers and bottles in all shapes.
Semi-Automatic PET Bottle Blowing Machine Bottle Making Machine Bottle Moulding Machine
PET Bottle Making Machine is suitable for producing PET plastic containers and bottles in all shapes.
External Current Transformer
● Convenient for modification project
● Max input current: 100A/6A
● Convenient for modification project
● Max input current: 100A/6A
3-channel Temperature Measuring
● Thermistor: NTC temperature sensor
● Measuring Range: -40℃~+125℃
● Thermistor: NTC temperature sensor
● Measuring Range: -40℃~+125℃
hannel RS485 Communication
● Protocol: MODBUS-RTU
● 1 channel RS485 or 2 channel RS485 both optional
● Protocol: MODBUS-RTU
● 1 channel RS485 or 2 channel RS485 both optional
DO/DI Switch
● 1 channel DO
● 1 channel DI
● 1 channel DO
● 1 channel DI
HMI for Parameters Setting
● Code
● Protocol
● Address
● Baud rate
● Parity
● All Display
● Code
● Protocol
● Address
● Baud rate
● Parity
● All Display
Infrared Communication for Remote Meter Reading
● Built-in infrared communication
● Easy Remote Meter Reading
● Built-in infrared communication
● Easy Remote Meter Reading
Technical Parameter
1.Function description
Function | Function description | Function provide |
Measurement of kWh | Active kWh (positive and negative) | ■ |
Reactive kWh (positive and negative) | ■ | |
A, B, C phase positive active kWh | ■ | |
Measurement of electrical parameters | U、I、P、Q、S、PF、F | ■ |
■ | ||
Measurement of | 2~31ST Voltage and current harmonic | □Note 1 |
LCD Display | 8 bits section LCD display, background light | ■ |
Key programming | 4 keys to communication and set parameters | ■ |
Pulse output | Active pulse output | ■ |
Reactive pulse output | □Note 2 | |
Clock pulse output | □Note 2 | |
Multi-tariff and functions | Active switch input | □Note 3 |
Switch output | □Note 2 | |
Adapt 4 time zones, 2 time interval lists, 14 time interval by day and 4 tariff rates | □ | |
Max demanded kWh and time happened | □ | |
Frozen data on last 48 months, last 90days | □ | |
Date, time | □ | |
Communication | Infrared communication | ■ |
The first communication path: Communication interface: RS485, Communication protocol: MODBUS-RTU | □ | |
The second communication path: Communication interface: RS485, Communication protocol: MODBUS-RTU | □Note 3 | |
Temperature measurement | Support 3 outlay NTC temperature | □Note 4 |
2.Technical parameter
Specification | 3 phase 3 wires, 3 phase 4 wires | ||
Voltage | Reference voltage | 3×100V、 3×380V、3×57.7/100V、 3×220/380V | |
Consumption | <10VA(Single phase) | ||
Impedance | >2MΩ | ||
Accuracy class | Error±0.2% | ||
Current | Input current | 3×1(6)A (second connection with CTs’ cable already on site via external CTs of ADL3000-E/CT) 3×10(100)A (first connection with 3-phase load line via external CTs of ADL3000-E/CT) | |
Consumption | <1VA(Single phase rated current) | ||
Accuracy class | Error±0.2% | ||
Power | Active, reactive, apparent power, error±0.5℅ | ||
Frequency | 45~65Hz, Error±0.2% | ||
Temperature | -40℃~99℃ | ||
Energy | Active energy(Accuracy class:0.5, 1), reactive energy(Accuracy class 2) | ||
Clock | ≤0.5s/d | ||
Energy pulse output | 1 active optocoupler output, 1 reactive optocoupler output | ||
Switching output | 1 Switching output | ||
Switching input | 1 optocoupler input | ||
Width of pulse | 80±20ms | ||
Pulse constant | 6400imp/kWh,400imp/kWh(Correspond with the basic current) | ||
Interface and communication | RS485:Modbus RTU | ||
Range of communication address | Modbus RTU:1~ 247; | ||
Baud rate | 1200bps~19200bps | ||
Relative temperature | -25℃~+55℃ | ||
Relative humidity | ≤95℅(No condensation) |
Wiring Illustration
Dimension & Installation
Solution Structure
Certification
Company Profile
FAQ
Semi-Automatic PET Bottle Blowing Machine Bottle Making Machine Bottle Moulding Machine
PET Bottle Making Machine is suitable for producing PET plastic containers and bottles in all shapes.
Semi-Automatic PET Bottle Blowing Machine Bottle Making Machine Bottle Moulding Machine
PET Bottle Making Machine is suitable for producing PET plastic containers and bottles in all shapes.